EN 18.304.1.0/02.18
47
1
Description:
This high-precision pressure transmitter
was specially developed and adapted for
the sophisticated measurement demands of
steelworks technology.
The instrument has a very robust sensor cell
withathin-lmstraingaugeonastainless
steel membrane.
Itsoutstandingspecicationsinrespect
of temperature effect (temperature drift
for zero point and span are in each case
max.≤±0.01%FS/°C)andaccuracy
(≤±0.125%FStyp.)makeitideallysuited
for use in the environmental conditions found
in steelworks.
TheexcellentEMCcharacteristicsguarantee
signal stability during the harshest high-
frequency, electromagnetic interference.
Additional protection against humidity and
vibrations is achieved by encapsulation. A
heat shrink sleeving is used to protect the
sensor from bending.
Technical data:
Input data
Measuring ranges
1)
bar 16 60 100 150 250 300 350 400 500 600 1000
Overload pressures bar 32 120 200 500 800 900 900 900 1000 1000 1600
Burst pressure bar 200 300 500 1000 2000 2000 2000 2000 2000 2000 3000
Mechanical connection
1)
G1/4AISO1179-2with0.5mmorice
G1/2AISO1179-2with0.5mmorice
Tightening torque, recommended 20Nm(G1/4);45Nm(G1/2)
Partsincontactwithuid Mech. connection:
Seal:
Stainlesssteel
FKMforG1/4,NBRforG1/2
Output data
Output signal, permitted load resistance 4..20mA,2-conductor
R
Lmax.
= (U
B
-10V)/20mA[kΩ]
0..20mA,3-conductorsource
R
Lmax.
= (U
B
-4V)/20mA[kΩ]
Accuracyacc.toDIN16086,
terminal based
≤±0.125%FStyp.
≤±0.25%FSmax.
Accuracy,B.F.S.L. ≤±0.06%FStyp.
≤±0.125%FSmax.
Temperature compensation
Zero point
≤±0.005%FS/°Ctyp.
≤±0.01%FS/°Cmax.
Temperature compensation
Span
≤±0.005%FS/°Ctyp.
≤±0.01%FS/°Cmax.
Non-linearityacc.toDIN16086,
terminal based
≤±0.15%FSmax.
(below100bar±0.2%FSmax.)
Hysteresis ≤±0.1%FSmax.
Repeatability ≤±0.05%FS
Risetime ≤1.0ms
Long-term drift ≤±0.1%FStyp./year
Environmental conditions
Compensatedtemperaturerange -25..+85°C
Operating temperature range
2)
-25..+85°C/-40..+85°C
Storagetemperaturerange -40..+100°C
Fluidtemperaturerange
2)
-25..+100°C/-40..+100°C
mark
EN61000-6-1/2/3/4
mark
3)
Certicate-No.:E318391
Vibrationresistanceacc.to
DINEN60068-2-6at10..500Hz
≤25g
Protectionclassacc.toDINEN60529
IP67(M12x1whenanIP67matingconnectorisused)
IP68(jacketedcable)
Other data
Supplyvoltage
whenappliedacc.toULspecications
10..30VDC2-conductor/3-conductor
-limitedenergy-acc.to9.3UL61010;Class2;
UL1310/1585;LPSUL60950
Residualrippleofsupplyvoltage ≤5%
Currentconsumption ≤25mA
Additional protection against water, humidity
and vibration
Encapsulation of the device, cable outlet with strain
relief, heat shrink sleeving
Life expectancy >10millioncycles(0..100%FS)
Weight ~180gplus90g/mcable
Note: Reversepolarityprotectionofthesupplyvoltage,excessvoltage,overrideandshortcircuit
protection are provided.
FS (Full Scale)=relativetocompletemeasuringrange
B.F.S.L. = Best Fit Straight Line
1)
1000baronlywithmech.connectionG1/2AISO1179-2andviceversa
2)
-25°CwithFKMseal,-40°Conrequest
3)
Environmentalconditionsacc.to1.4.2UL61010-1;C22.2No.61010-1
Pressure Transmitter
HDA4800 forIronandSteelworks
Relative pressure Accuracy 0.125 %
Includestestcerticate