Description:
The pressure transmitter series HDA 4400
has a pressure measurement cell with
thin-lm strain gauge on a stainless steel
membrane.
The output signals 4 .. 20 mA or 0 .. 10 V
enable connection to all measurement and
control devices of HYDAC ELECTRONIC
GMBH as well as standard evaluation
systems (e.g. PLC controls).
The main elds of application are in mobile
or industrial hydraulics and pneumatics.
Technical data:
Input data
Measuring ranges bar 16 40 60 100 250 400 600 1000 1600 2000
Overload pressures bar 32 80 120 200 500 800 1000 1600 2400 3000
Burst pressure bar 200 200 300 500 1000 2000 2000 3000 3000 4000
Mechanical connection G1/4 A ISO 1179-2
G1/2 B DIN EN 837
Tightening torque, recommended 20 Nm (G1/4); 45 Nm (G1/2)
Parts in contact with uid Mech. connection: Stainless steel
Seal: FKM
Output data
Output signal, permitted load resistance 4 .. 20 mA, 2-conductor
R
Lmax
.
= (U
B
- 8 V) / 20 mA [kΩ]
0 .. 10 V, 3-conductor
R
Lmin
= 2 kΩ
Accuracy acc. to DIN 16086,
terminal based
≤ ± 0.5 % FS typ.
≤ ± 1 % FS max.
Accuracy, B.F.S.L. ≤ ± 0.25 % FS typ.
≤ ± 0.5 % FS max.
Temperature compensation
Zero point
≤ ± 0.015 % FS / °C typ.
≤ ± 0.025 % FS / °C max.
Temperature compensation
Span
≤ ± 0.015 % FS / °C typ.
≤ ± 0.025 % FS / °C max.
Non-linearity acc. to DIN 16086,
terminal based
≤ ± 0.3 % FS max.
Hysteresis ≤ ± 0.4 % FS max.
Repeatability ≤ ± 0.1 % FS
Rise time ≤ 1 ms
Long-term drift ≤ ± 0.3 % FS typ. / year
Environmental conditions
Compensated temperature range -25 .. +85 °C
Operating temperature range -25 .. +85 °C
Storage temperature range -40 .. +100 °C
Medium temperature range
1)
-40 .. +100 °C / -25 .. +100 °C
mark EN 61000-6-1 / 2 / 3 / 4
mark
2)
Certicate no.: E318391
Vibration resistance acc. to
DIN EN 60068-2-6 at 10 .. 500 Hz
≤ 20 g
Shock resistance acc. to DIN EN 60068-2-29 ≤ 100 g / 6 ms
Protection class acc. to DIN EN 60529
3)
IP 65 (Binder 714 M18)
IP 67 - M12x1 male connector
- Male connector EN175301-803
Other data
Supply voltage
when applied acc. to UL specications
8 .. 30 V DC 2-conductor
12 .. 30 V DC 3-conductor
- limited energy - acc. to 9.3 UL 61010; Class 2;
UL 1310/1585; LPS UL 60950
Residual ripple of supply voltage ≤ 5 %
Current consumption ≤ 25 mA
Life expectancy
4)
> 10 million cycles
0 .. 100 % FS
Weight ~ 150 g
Note: Reverse polarity protection of the supply voltage, excess voltage, override and short circuit
protection are provided.
FS (Full Scale) = relative to complete measuring range
B.F.S.L. = Best Fit Straight Line
1)
-25 °C with FKM seal, -40 °C on request
2)
Environmental conditions acc. to 1.4.2 UL 61010-1; C22.2 No 61010-1
3)
With mounted mating connector in corresponding protection class
4)
Measuring ranges ≥ 1000 bar: > 1 million cycles (0 .. 100 % FS)
Pressure Transmitter
HDA 4400
Relative pressure Accuracy 0.5 %
EN 18.305.5/02.18
16
1
Pin connections:
Dimensions:
Binder series 714 M18
Mechanical connection
1 = G1/2 B DIN EN 837
(only for
pressure ranges "1600 and 2000 bar")
4 = G1/4 A ISO 1179-2 (male)
Electrical connection
4 = male, 4 pole Binder series 714 M18
(mating connector not supplied)
5 = male, 3 pole + PE, EN175301-803
(mating connector supplied)
6 = male M12x1, 4 pole
(mating connector not supplied)
Output signal
A = 4 .. 20 mA, 2-conductor
B = 0 .. 10 V, 3-conductor
Measuring ranges in bar
016; 040; 060; 100; 250; 400; 600; 1000
1600; 2000 bar (only with mech. connection code "1")
Modication number
000 = standard
Accessories:
Appropriate accessories, such as mating connectors, can be found in the Accessories brochure.
Pin HDA 44X4-A HDA 44X4-B
1 n.c. +U
B
2 Signal + Signal
3 Signal - 0 V
4 n.c. n.c.
Pin HDA 44X5-A HDA 44X5-B
1 Signal + +U
B
2 Signal - 0 V
3 n.c. Signal
Housing Housing
Pin HDA 44X6-A HDA 44X6-B
1 Signal + +U
B
2 n.c. n.c.
3 Signal - 0 V
4 n.c. Signal
EN175301-803
M12x1
Prole seal
ring
Male connector
3p+PE EN175301-803
Male connector
4 pole
Hex AF
width 27
Elastomer
prole seal
ring
DIN3869
Male connector
Binder series 714
4 pole
Model code:
HDA 4 4 X XXXXX000
Note:
The information in this brochure relates to the
operating conditions and applications described.
For applications or operating conditions not
described, please contact the relevant technical
department.
Subject to technical modications.
HYDAC ELECTRONIC GMBH
Hauptstr. 27, 66128 Saarbrücken
Germany
Phone +49 (0)6897 509-01
Fax +49 (0)6897 509-1726
e-mail: electronic@hydac.com
Internet: www.hydac.com
Hex AF
width 27
Flat seal ring Cu