EN 18.305.5/02.18
15
1
Description:
The pressure transmitter series HDA 4400
has a pressure measurement cell with
thin-lm strain gauge on a stainless steel
membrane.
The output signals 4 .. 20 mA or 0 .. 10 V
enable connection to all measurement and
control devices of HYDAC ELECTRONIC
GMBH as well as standard evaluation
systems (e.g. PLC controls).
The main elds of application are in mobile
or industrial hydraulics and pneumatics.
Technical data:
Input data
Measuring ranges bar 16 40 60 100 250 400 600 1000 1600 2000
Overload pressures bar 32 80 120 200 500 800 1000 1600 2400 3000
Burst pressure bar 200 200 300 500 1000 2000 2000 3000 3000 4000
Mechanical connection G1/4 A ISO 1179-2
G1/2 B DIN EN 837
Tightening torque, recommended 20 Nm (G1/4); 45 Nm (G1/2)
Parts in contact with uid Mech. connection: Stainless steel
Seal: FKM
Output data
Output signal, permitted load resistance 4 .. 20 mA, 2-conductor
R
Lmax
.
= (U
B
- 8 V) / 20 mA [kΩ]
0 .. 10 V, 3-conductor
R
Lmin
= 2 kΩ
Accuracy acc. to DIN 16086,
terminal based
≤ ± 0.5 % FS typ.
≤ ± 1 % FS max.
Accuracy, B.F.S.L. ≤ ± 0.25 % FS typ.
≤ ± 0.5 % FS max.
Temperature compensation
Zero point
≤ ± 0.015 % FS / °C typ.
≤ ± 0.025 % FS / °C max.
Temperature compensation
Span
≤ ± 0.015 % FS / °C typ.
≤ ± 0.025 % FS / °C max.
Non-linearity acc. to DIN 16086,
terminal based
≤ ± 0.3 % FS max.
Hysteresis ≤ ± 0.4 % FS max.
Repeatability ≤ ± 0.1 % FS
Rise time ≤ 1 ms
Long-term drift ≤ ± 0.3 % FS typ. / year
Environmental conditions
Compensated temperature range -25 .. +85 °C
Operating temperature range -25 .. +85 °C
Storage temperature range -40 .. +100 °C
Medium temperature range
1)
-40 .. +100 °C / -25 .. +100 °C
mark EN 61000-6-1 / 2 / 3 / 4
mark
2)
Certicate no.: E318391
Vibration resistance acc. to
DIN EN 60068-2-6 at 10 .. 500 Hz
≤ 20 g
Shock resistance acc. to DIN EN 60068-2-29 ≤ 100 g / 6 ms
Protection class acc. to DIN EN 60529
3)
IP 65 (Binder 714 M18)
IP 67 - M12x1 male connector
- Male connector EN175301-803
Other data
Supply voltage
when applied acc. to UL specications
8 .. 30 V DC 2-conductor
12 .. 30 V DC 3-conductor
- limited energy - acc. to 9.3 UL 61010; Class 2;
UL 1310/1585; LPS UL 60950
Residual ripple of supply voltage ≤ 5 %
Current consumption ≤ 25 mA
Life expectancy
4)
> 10 million cycles
0 .. 100 % FS
Weight ~ 150 g
Note: Reverse polarity protection of the supply voltage, excess voltage, override and short circuit
protection are provided.
FS (Full Scale) = relative to complete measuring range
B.F.S.L. = Best Fit Straight Line
1)
-25 °C with FKM seal, -40 °C on request
2)
Environmental conditions acc. to 1.4.2 UL 61010-1; C22.2 No 61010-1
3)
With mounted mating connector in corresponding protection class
4)
Measuring ranges ≥ 1000 bar: > 1 million cycles (0 .. 100 % FS)
Pressure Transmitter
HDA 4400
Relative pressure Accuracy 0.5 %