E 18.304.5/11.13
33
2
3
4
5
6
Electronic
Pressure Transmitter
HDA 3800
for Iron & Steel Works Applications
Description:
This high-precision pressure
transmitter was specially developed
and adapted for the sophisticated
measurement demands of steelworks
technology.
The instrument has a very robust
sensor cell with a thin-lm strain
gauge on a stainless steel membrane.
Its outstanding specications
in respect of temperature effect
(temperature drift for zero point and
range are in each case max.
≤ ± 0.01 % FS / °C) and accuracy
(
≤ ± 0.15 % FS typ.)
make it ideally
suited for use in the environmental
conditions found in steelworks.
The excellent EMC characteristics
guarantee signal stability during the
harshest high-frequency, electro-
magnetic interference.
Special features:
Accuracy ≤ ± 0.15 % FS typ.
Specially designed for use in
steelworks and rolling mills
Highly robust sensor cell
Very small temperature error
Excellent EMC characteristics
Excellent long term stability
Technical data:
Input data
Measurement ranges
1)
16; 60; 100; 150; 250; 300; 350;
400; 500; 600 bar
Overload pressures 32; 120; 200; 500; 800; 900; 900;
900; 900; 1000 bar
Burst pressures 200; 300; 500; 1000; 2000; 2000; 2000;
2000; 2000; 2000 bar
Mechanical connection G1/4 A DIN 3852
G1/2 A DIN 3852
Torque value 20 Nm (G1/4 A)
45 Nm (G1/2 A)
Parts in contact with medium
Mech. conn.:
Stainless steel
Seal: FPM (G1/4 A)
NBR O-ring (G1/2 A)
Output data
Output signal, permitted load resistance 4 .. 20 mA, 2 conductor
R
Lmax
.
= (U
B
- 10 V) / 20 mA [kW]
0 .. 20 mA, (3 conductor rising)
R
Lmax
.
= (U
B
- 10 V) / 20 mA [kW]
Accuracy to DIN 16086 ≤ ± 0.15 % FS typ.
Max. setting ≤ ± 0.3 % FS max.
Accuracy at min. setting ≤ ± 0.1 % FS typ.
(B.F.S.L.) ≤ ± 0.15 % FS max.
Temperature compensation ≤ ± 0.005 % FS / °C typ.
Zero point ≤ ± 0.01 % FS / °C max.
Temperature compensation ≤ ± 0.005 % FS / °C typ.
Over range ≤ ± 0.01 % FS / °C max.
Non-linearity at max. setting ≤ ± 0.2 % FS max.
to DIN 16086 (from 100 bar ≤ ± 0.15 % FS max.)
Hysteresis ≤ ± 0.1 % FS max.
Repeatability ≤ ± 0.05 % FS
Rise time ≤ 1.5 ms
Long-term drift ≤ ± 0.1 % FS typ. / year
Environmental conditions
Compensated temperature range -25 .. +85 °C
Operating temperature range
2)
-40 .. +85°C / -25 .. +85 °C
Storage temperature range -40 .. +100 °C
Fluid temperature range
2)
-40 .. +100 °C / -25 .. +100 °C
mark EN 61000-6-1 / 2 / 3 / 4
Vibration resistance to ≤ 25 g
DIN EN 60068-2-6 at 10 .. 500 Hz
Protection class to IEC 60529 IP 68
Other data
Supply voltage 2 conductor 10 .. 30 V DC
Supply voltage 3 conductor 12 .. 30 V DC
Residual ripple of supply voltage ≤ 5 %
Current consumption 3 conductor approx. 25 mA
Life expectancy > 10 million cycles, 0 .. 100 % FS
Weight ~ 210 g
Note: Reverse polarity protection of the supply voltage, excess voltage, override
and short circuit protection are provided.
FS (Full Scale) = relative to complete measuring range
B.F.S.L.= Best Fit Straight Line
1)
Other measuring ranges on request
2)
-25 °C with FPM seal, -40 °C on request