1
EN 7.591.0 / 11.21
Return Line Filter
RFB Compact
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Design
The RFB lters are suitable for
smaller ow rates. The lter is mounted
in the tank and ow passes through
it through a pipe connection from
below. The optimal ow conditions
created by ow from beneath guar
antee optimum air separation, high
pulsation stability and very long
lter service lives.
Standard equipment
With bypass valve
Inlet as plugin connection
Patented lter
Without clogging indicator
With nonreturn valve
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly moni
tored according to the following
standards:
ISO 2941, ISO 2942, ISO 2943,
ISO 3724, ISO 3968, ISO 11170,
ISO 16889.
The lter elements are available
with 6 bar pressure stability values.
RFB Compact
100
RFB Compact
155
RFB Compact
210
1.4 SEALS
NBR (= Perbunan)
1.5 MOUNTING
As intank lter
1.6 SPECIAL MODELS AND
ACCESSORIES
Seals in FKM
Without nonreturn valve
Bypass 0.8 bar,
other pressures on request
Filter cover with spherical
dome for larger tolerance range
for installation dimension
Helios pleat in element for lower
pressure losses at lter element
1.7 SPARE PARTS
See spare parts list
1.8 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils HL to HVLP (DIN 51524)
Lubrication oils (DIN 51517, API,
ACEA, DIN 51515, ISO 6743)
Compressor oils (DIN 51506)
Biodegradable operating uids:
HETG, HEES, HEPG (VDMA 24568)
1.3 FILTER SPECIFICATIONS
Symbol
Nominal pressure 10 bar
Maximum nominal ow rate 210 l/min
Temperature range 20 °C to +100 °C
Material of lter head PA 66 GF30
Bypass cracking pressure 2.5 bar
2
EN 7.591.0 / 11.21
RFB 155 UMC 010 V X B V F 0 V N A VX X 1 /-XXX
Filter type
RFB
Size
100, 155, 210
Filter material
ULP glass bre
UMC glass bre with prelter
Filtration rating in mm
ULP 010, 025
UMC 010, 020
Bypass valve
C with 0.8 bar bypass valve
V standard: with 2.5 bar bypass valve
Magnetic core
X without magnetic core
Pressure range
B 10 bar
Connection position
V centrally from below
Tube version
F outlet lm at element
Orientation of pipe connection to clogging indicator
0 without indicator
Non-return valve
X without valve
V with valve
Seal
N NBR (Perbunan)
V FKM
Cover version
A with central thread without spherical dome
B with central thread with spherical dome (“swivel” version)
Clogging indicator
VX without clogging indicator
Response pressure of clogging indicator
X without
Modication number
X the latest version is always supplied
Supplementary details
H helios pleat in element
2. MODEL CODE (also order example)
2.1 FILTER ASSEMBLY
3
EN 7.591.0 / 11.21
UMC – 0010 – 089 – X513 – Q – P – RT / x
Filter medium / design
ULP
UMC
Filtration rating
0010; 0025 for ULP
0010; 0020 for UMC
Diameter
089 RFB compact
Model code
X510 for RFB 0100 ...
X513 for RFB 0155 ...
X516 for RFB 0210 ...
Quality protection
Q with QP
K with QP and with valve ap
Seal
P mouldedon sealing lip
Packaging
RT RT package
Supplementary details
2.2 SPARE ELEMENT
4
EN 7.591.0 / 11.21
3. FILTER CALCULATION / DIMENSIONING
3.1 PERFORMANCE CURVES FOR FILTER ASSEMBLY
The total performance curves for element UMC / ULP…
apply to mineral oil with a density of 0.86 kg/dm³ and
a kinematic viscosity of 30 mm²/s.
3.2 MAXIMUM PEAK FLOW RATE
The following maximum permitted peak ow rates (Q
max
)
in l/min are possible for the various sizes:
Information regarding dimensioning:
The hydraulic load on the lter element is primarily
deter mined by the ow rate and the geometry of
the particular lter element. Exceeding the maximum
permitted ow rate (Q
max
) and therefore the permitted
hydraulic load can destroy the lter element.
Even the choice of operating medium can inuence
system performance and lead to problems during use
such as electrostatic discharges.
Adherence to the maximum permitted ow rate should
always be ensured throughout the system project planning
process.
If you have any questions regarding dimensioning
or project planning, please contact the technical sales
department at HYDAC Filtertechnik.
3.3 COVER VERSION
To balance out manufacturing tolerances specically in the
case of plastic tanks, an optional cover version with inte grated
spherical dome is available for the RFB Compact.
This “swivel” version provides perfect balancing of process
related production tolerations in the tank construction.
The maximum tolerances are given in section 4.2.
Size Q
max
[l/min]
100 150
155 230
210 320
Standard Swivel
0.00
0.10
0.20
0.30
0.40
0.50
0.60
UMC 10 µm
ULP 10 µm
0 50
100 150 200
Q [l/min]
p [bar]
0.00
0.10
0.20
0.30
0.40
0.50
0.60
UMC 10 µm
ULP 10 µm
0 50 100 150 200 250 300
Q [l/min]
p [bar]
0.00
0.10
0.20
0.30
0.40
0.50
0.60
UMC 10 µm
ULP 10 µm
0 50 100 150 200 250 300 350 400
Q [l/min]
p [bar]
RFB 100
RFB 155
RFB 210
5
EN 7.591.0 / 11.21
4. DIMENSIONS
4.1 HOUSING DIMENSIONS
Size Version h1 h2 h3 x Ø d1 Ø d2 Ø d3 AF Weight incl. element [kg]
100
Standard
246
21.0
170
267.0
S 105 x 4 115 89.4
36 0.56
Swivel 28.5 274.5 41 0.61
150
Standard
331
21.0
235
352.0 36 0.69
Swivel 28.5 359.5 41 0.73
210
Standard
416
21.0
304
437.0 36 0.80
Swivel 28.5 444.5 41 0.85
Version: standard
h1
h3
h2
x
Ø d1
R
Ø d3
Ø d2
SW
Version: swivel
h1
h3
h2
x
Ø d1
Ø d3
R
Ø d2
SW
6
EN 7.591.0 / 11.21
4.2 TANK FLANGE AND PIPE CONNECTION
Steel tank Plastic tank
Notice:
1. Flanges, piping and screw connections
are not included in the scope of delivery
2. Dimension of piping in acc. with DIN EN 10305
3. Area under the lter element
4. Possible design of the return line connection.
Sealing between tank and port in acc. with ISO 6149.
5. Take seal shrinkage into account with critical oils
6. Tolerance for operationrelated deformation not taken
into account – permitted range must be dened between
customer and manufacturer
Size Version h4 h5 Ød4 α
100
Standard
202 251
4.0 0.5°
Swivel 20.0 3.0°
150
Standard
287 336
5.5 0.5°
Swivel 26.0 3.0°
210
Standard
372 421
7.0 0.5°
Swivel 32.0 3.0°
Ø 109.65 ±0.3
Ø 109.65 ±0.7 (5)
S 105 x 4
S 105 x 4
Ø 130
Ø 118
Ø 35
±0.15 (2)
Ø 90 (3)
Ø 90 (3)
Ø 35
±0.15 (2)
Ø 33.5
Ø d4 A B
Ø 33.5
R 0.6
±0.15
R 0.6 ±0.15
15°
15°
60°
60°
7.4 ±0.3
7.4 ±0.3
44 ±4 (6)
h5
35 min.
35 min.
30
±10
23 ±3
h4 ±4
h5
A
B
B
A
A
A
0.2
0.4
Tank
Tank
α max.
α max.
α max.
α max.
R 0.2 R 0.2
(1)
(1)
Rz10 Rz10
Rz10
Rz16
Rz10
Rz16
R 0.2 R 0.2
(2 to 3)
(2 to 3)
Ø d4 A B
20 °
20 °
Tank
(4)
Tank
α max.
α max.
α max.
α max.
7
EN 7.591.0 / 11.21
5. MAINTENANCE
5.1 MAINTENANCE
Design
Please follow the maintenance instructions on the last page!
Installation
Before installing the lter, check the permitted operating
pressure of the system – it must be lower than permitted
operating pressure of the lter. Refer to the identication
plate on the lter!
Start-up
Check that the correct lter element is tted, apply the cover
and secure it. Switch on the hydraulic system and check lter
for leakage.
Vent lter at an appropriate point in the system.
Tightening torques
5.2 CHANGING THE ELEMENT
Removing the element
1. Switch off hydraulic system and release lter pressure
(if necessary release the pressure in the tank).
2. Loosen the cover by turning it anticlockwise
and pull out the cover with the element,
allowing any adhering oil to drip off.
3. Loosen the bayonet connection between cover
and element from the catch with an anticlockwise
rotation and remove cover.
4. Clean cover and examine for mechanical damage.
5. Check Oring – replace if necessary.
Fitting the element
1. Clean all removed parts and check for damage.
Replace damaged parts and ensure that sealing surfaces,
threads and Orings are wetted with clean operating uid.
2. When installing a new lter element (1), check that
the designation corresponds to that of the old element (1).
3. Place element (1) on the cover and turn it clockwise until
the bayonet connection has engaged. For the “swivel”
cover version, align the thread coaxially to the element.
This makes it easier to insert the connection in the tank.
4. Push element with cover into the housing ange
and push the element onto the connection.
5. Place the cover on the thread ange and tighten it
to the stop clockwise and ngertight – recommended
torque 30 Nm. For the “swivel” cover version, ensure
that the thread moves freely – the cover can be tilted
to align it to the internal thread on the ange.
6. Switch on hydraulic system and vent lter at a suitable
point in the system.
7. Check lter for leakage.
NOTICE:
Filter elements are to be disposed of
in an environmentally safe manner.
Thread,
cover
Recommended
tightening torque
S105 x 4 30 Nm
8
EN 7.591.0 / 11.21
6. SPARE PARTS
6.1 SPARE PARTS DRAWING
6.2 SPARE PARTS LIST
No. Version Part number
1 Filter element See point 2.2 Spare element
2 Seal, cover 200337 Oring 97.8 x 5.33 – NBR – 70Sh
2
1
2
1
9
EN 7.591.0 / 11.21
7. MAINTENANCE
INSTRUCTIONS
7.1 USER INSTRUCTIONS
FOR FILTERS
Caution: lter under pressure:
before any work is carried
out on the lter, ensure the
pressure chamber con cerned
(lter housing) is depressurised.
On no account may any modications
(welding, drilling, opening by force etc.)
be carried out on the lter.
Filter housing must be earthed.
When working on, or in the vicinity of,
hydraulic systems, naked ames,
spark generation and smoking are
forbidden.
Hydraulic oils and waterpolluting uids
must not be allowed to enter the soil,
watercourses or sewer systems.
Please ensure safe and environmen
tally friendly disposal of hydraulic oils
and uids. The relevant regulations
in the country concerned with regard
to ground water pollution, used oil
and waste must be complied with.
Whenever work is carried out on
the lter, be prepared for hot oil
to escape which can cause injury
or scalding as a result of its high
pressure or temperature.
The owner must take
appro priate action (e.g.
air venting) to prevent the
formation of air pockets.
Repairs, maintenance work and com
missioning must only be carried out
by trained personnel. Allow the lter
to cool before handling. The stipula
tions in the machine or system opera
ting instructions must be followed.
Statutory accident prevention regula
tions, safety regulations and safety
data sheets for uids must be ob
served.
This lter must only be put
into operation in conjunction
with a machine or system.
The lter must only be used
as stipulated in the operating instruc
tions of the machine or system.
This lter must only be operated
using hydraulic or lubricating uid.
It is the responsibility of the operator
to comply with the water regulations
of the country concerned.
7.2 MAINTENANCE, GENERAL
This section describes maintenance
work which must be carried out
periodically. The operational safety
and service life of the lter, and
whether it is ready for use, depend
to a large extent on regular and
careful maintenance.
7.3 BASIC PRINCIPLES
This document is for information
purposes and for the avoidance
of dangers during installation,
during the operation of the system
and for the handling of operating
materials.
Safe and economical operation of
the system is only possible if the
installation manual is observed closely.
This installation manual does not
sub stitute the operating instructions
of the device or the system.
The individual installation instructions
for the installed components of the
overall system also apply.
7.4 QUALIFICATIONS OF
PERSONNEL / TARGET GROUP
This installation manual is exclusively
geared towards use by trained
specialists and it must be made
accessible at the place of use.
7.5 INTENDED USE
The lter is only suitable for the ltra
tion of operating uids.
The lter is not useable on its own.
The lter is intended for installation
in a hydraulic system.
Any alternative or more extensive
use shall not be considered intended
use. HYDAC Filtertechnik GmbH will
assume no liability for any loss or
damage as the result thereof.
7.6 MAINTENANCE MEASURES
Spare parts must conform to the
technical requirements specied
by the manufacturer. This is always
ensured when using original
HYDAC spare parts.
Tools, working area and devices
are to be kept clean.
After disassembling the lter,
clean all parts, check them
for damage or wear and replace
them if necessary.
When changing a lter element,
a high level of cleanliness must
be observed!
7.7 EXPLANATION OF SYMBOLS
AND WARNINGS
This type of safety symbol or
instruction ...
Danger
indicates a situation that
is dangerous in a threat
ening manner and will lead
to death or serious injury if it is not
avoided.
Warning
indicates a situation
that could lead to death
or serious injury, or serious
harm to health, if it is not avoided.
Info
indicates a notice regarding
correct handling of the
pressure equipment. Non
observance of these notes may lead
to damage of the pressure equipment
or its immediate surroundings.
Disposal
identies special measures
for environmental protection.
Professional, environmentally
friendly material disposal.
Notice
indicates a notice regarding
special user tips and other specially
useful or important information.
7.8 INTERVAL BETWEEN ELEMENT
CHANGES
In principle we recommend that
the lter element is changed after
one year of operation at the latest.
If no external clogging indicator can
be tted, we recommend changing
the elements at specic intervals
(the frequency of changing the lter
elements depends on the lter calcu
la tion and the conditions under which
the lter is operated). When lter
ele ments are subject to high dynamic
loading it may prove necessary to
change them more frequently.
The same applies when the hydraulic
system is commissioned or repaired
or when the oil is changed.
Warning
Danger
Info
10
EN 7.591.0 / 11.21
7.9 CUSTOMER INFORMATION
CONCERNING THE MACHINERY
DIRECTIVE 2006/42/EC
Hydraulic lters are uid power
parts / components and are therefore
ex clu ded from the scope of the
Ma chinery Directive. They do not
bear the CE mark!
Before using these components,
ensure compliance with the speci 
cations provided by HYDAC Filter
technik GmbH in this documentation.
The specications also contain
information on the relevant essential
health and safety requirements
(based on Machinery Directive
2006/42/EC) that are to be applied
by the user.
We hereby declare that the lters
are intended to be incorporated into
machinery within the terms of the
Machinery Directive 2006/42/EC.
It is prohibited to put the lters into
service until the device as a whole
conforms to the provisions of the
Machinery Directive. Furthermore,
our Terms of Sale and Delivery
are available on our website
(www.hydac.com).
HYDAC Filtertechnik GmbH
Industriegebiet
D-66280 Sulzbach/Saar
Tel.: 0 68 97 / 50901
Fax: 0 68 97 / 509300
Internet: www.hydac.com
Email: lter@hydac.com
NOTE
The information in this brochure relates
to the operating conditions and appli ca
tions described.
For applications or operating condi tions
not described, please contact the rele
vant technical department. Subject to
technical modications.
In accordance with our Terms of Sale
and Delivery, guarantees are subject
to the use of original HYDAC parts only
and correct tting, as per service and
maintenance instructions.
EXCLUSION OF LIABILITY
This installation manual was made
to the best of our knowledge. Never
theless and despite the greatest care,
it cannot be excluded that mistakes
could have crept in.
Therefore please understand that in
the absence of any provisions to
the contrary hereinafter, our warranty
and liability – for any legal reasons
whatsoever – are excluded in respect
of the information in this installation
manual.
In particular, we shall not be liable
for lost prot or other nancial loss.
This exclusion of liability does not apply
in cases of intent or gross negli gence.
Moreover, it does not apply to defects
which have been deceitfully concealed
or whose absence has been guaranteed,
nor in cases of culpable harm to life,
physical injury and damage to health.
If we negligently breach any material
contractual obligation, our liability
shall be limited to foreseeable damage.
Claims due to product liability shall