X
-Series
Nominal pressure: 350 bar
Nominal ow rate
l Pump port: 250 l/min
l Working ports: 160 l/min
with compensator and load holding
function
Load-Sensing Sectional
Control Valves
L
X
-6
EN 5.282.2 / 10.20
1
Table of contents
Product features 2
General information and functional description 2
l Overview 2
Technical data 4
Modular structure 5
Example of block specication and type code 6
Inlet plates 7
l Inlet plate CL17 7
l Universal inlet plate UL17 / UL17F 8
l Option blocks for inlet plate UL17F 9
Working sections 11
l Working sections B6 / LS6 / LS6F 11
l Main spool and pressure compensator 12
l LS pressure limitation 16
l Workport valves 17
l Operation units 18
l Spring caps 20
l Option blocks for working section LS6F 21
End plates 24
l End plate ER1 25
l End plates ER2 / ER27 / ER2F 25
l Option blocks for end plate ER2F 26
Solenoid valves and coils 27
Connection type, fastening and tie rods 28
Installation, usage and maintenance information 28
Dimensions 29
Type code 32
Ordering examples 35
Standard program
EN 5.282.2 / 10.20
2
Overview
Product features
l Load pressure independent ow control with
- Open Center (OC) system for xed displacement pump
- Closed Center (CC) system for variable displacement pump
l Flow-optimized valve design
l High mechanical and electrical resolution
l Compact size and low weight
l Modular design up to 8 working sections
l Types of operation (with/without hand lever):
- Hydraulic
- Electrohydraulic (on/off, proportional)
l Application-specic main spools with adjustable stroke limiter
l Shock/anti-cavitation valves for protection of actuators
General information
and functional description
The LX-6 is a proportional directional control valve according
to the load-sensing principle pre compensated.
The nominal ow rate to the working ports A and B is 160 l/min.
The main spool
2.1
determines the ow direction and
magnitude of ow rate.
Pressure control valves
2.4.3
and
2.4.4
are providing shifting
pressure to the left and right side of the main spool
2.1
to
control its position. The level of electric current determines the
level of pilot pressure and therefore the position of the main
spool.
Adjustable stroke limiters
2.4.1
and
2.4.2
can be set mechanically
to limit the maximum ow rate to the working ports A and B.
A
T
T
P
B
l Adjustable load sense pressure limitation (mechanically or
electro proportionally) causes the compensator to block ow
to the working ports A or B independently
l Direct-mounted option blocks for remote control
of LS and pilot oil supply
l End plates with additional pilot oil
supply options
l Areas of application:
- Cranes - Forestry
- Lifting platforms - Municipal vehicles
- Drilling machinery - Truck applications
- Construction - Stationary applications
- Agriculture
The pressure compensator
2.7
keeps the ow rate to the
actuator constant, even if the system pressure varies.
Pressure changes at the pump or working ports A and B
are compensated for each working section individually.
The maximum operating pressure can be adjusted by
LS pressure limitation for working ports A and B separately.
Shock / anti-cavitation valves
2.3.2
protect the working
ports A and B from pressure peaks. Anti-cavitation valves
2.3.1
protect the system from cavitation.
Shuttle valves are integrated into the working sections to
signal the highest load pressure for the valve stack to the inlet
plate or variable displacement pump.
2.7
Pressure compensator
2.1
Main spool
2.3.1
Workport valve port A (anti-cavitation valve)
2.3.2
Workport valve port B (shock / anti-cavitation valve)
2.4.1
Stroke limiter port A (clockwise rotation)
2.4.2
Stroke limiter port B (counterclockwise rotation)
2.4.3
Pressure control valve port A
2.4.4
Pressure control valve port B
2.7
2.1
2.4.1
2.4.2
2.4.42.4.32.3.22.3.1
EN 5.282.2 / 10.20
3
Overview
1.0
Inlet plate
1.1
Main axis of 3-way ow controller or pump pressure limiter
1.2
Pilot pressure relief valve of main axis 1.1
1.3
Option block for inlet plate
2.0
Working section
2.1
Main spool
2.2.1
LS pressure limitation port A
2.2.2
LS pressure limitation port B
2.3.1
Workport valve port A
2.3.2
Workport valve port B
2.4
Operation unit
2.4.1
Stroke limiter of main spool port A
2.4.2
Stroke limiter of main spool port B
2.5
Spring cap
2.6
Option block for working section
2.7
Pressure compensator
2.8
LS shuttle valve
3.0
End plate
3.1
Filter element
3.2
Pressure reducing valve for internal pilot oil supply
Ports
P Pump
MP Pump measuring port
T Tank
LS Load-sensing
A, B Working ports
C Pilot oil supply
Z Pilot drain
MY Pilot pressure measuring port (port B)
2.2.12.3.12.52.0
2.4
2.3.2
2.2.2
1.3
1.0
3.0
1.2
1.1
2.6
2.4.1 2.4.2
BABA
MY
MY
BA
LSLRLBZ LA
MY
A
B
A
B
PC
Z
C
P
MP
LX
P
L1
Z
LS
T
LS
LS
Z
C
P
T
LX
LS
A
B
A
B
LS
2.2.2 2.2.1
2.3.22.3.12.12.5
2.8
2.7
1.1
1.0 1.2 2.0 2.41.3
3.0
3.2
3.1
2.6
EN 5.282.2 / 10.20
4
Technical data
General data and operating conditions
No. of working sections: 1–8
1)
Installation position: Optional
Mass in kg: Inlet plate CL17 / UL17 / UL17F 6.1 / 6.0 / 5.9
Option block UD1 / UW 1... 0.4 / 1.1
Working section B6 / LS 6 / LS6F 5.1 / 4.7 / 4.6
Operation unit H... / E... 0.4 / 0.9
Hand lever 1 / 2 / 3 0.1
Option block LD1 / LW... / LW1... 0.3 / 1.2 / 1.6
End plate ER1 / ER 2 / ER27 / ER2F 4.0 / 3.9 / 4.2 / 3.9
Option block E1C 0.7
Tie rod for working sections 2 / 4 / 6 / 8 0.3 / 0.5 / 0.7 / 0.8
Connection type (thread type): BSPP (acc. to ISO 1179-1); SAE (acc. to ISO 11926-1 or SAE J1626)
Ambient temperature range: -20 to +60 °C
1)
Hydraulic uid temperature range: -20 to + 80 °C
1)
Painting: Standard primer and top coat RAL 9005 on inquiry
Hydraulic data
Nominal ow rate P / A, B 250 l/min / 160 l/min
Nominal pressure 350 bar
Max. operating
pressure at port:
P / A, B 350 bar / 420 bar
T 30 bar for external drained tank line Z
10 bar for internal connection Z → T
Z Drained to tank
Max. pilot pressure at port C / X, Y 30 bar
Pilot pressure range 6.5 to 20 bar hydraulic
4.5 to 20 bar electrohydraulic
Required control Δp at the control block 17 bar
Hydraulic uid Mineral oil (HL/HLP) acc. to DIN 51524, other hydraulic uids on inquiry
Viscosity range 10 – 400 mm
2
/s
Max. permitted degree of contamination
of the hydraulic uid
20/18/15 acc. to ISO 4406 (c)
Please contact HYDAC Filtration Technology to ensure system cleanliness
Electrical data
Supply voltages 12 V DC / 24 V DC
Solenoid data See section “Operation units” and “Solenoid valves and coils”
Connector type and IP protection class
(with mating connector mounted and locked)
AMP Junior Timer, 2-pin, axial / up to IP6K6
2)
Deutsch DT04, 2-pin, axial / up to IPX9K
2)
Ampliers and control devices See Product Catalogue 18.500 – Control Technology for Mobile Machines
1)
Deviation of data on inquiry only
2)
Mating plug-in connectors are not included
!
The technical data and characteristic curves were determined at a viscosity of 32 mm²/s
EN 5.282.2 / 10.20
5
Setup with left hand inlet plate
Modular structure
The LX-6 can be customised to different applications and machines.
The principle sectional design and modular structure consists of an inlet plate, max. 8 working sections and an end plate.
A complete control block is dened by a type code system.
Type code structure
General LX-6 _ _ / B 0
Connection type B (BSPP) or S (SAE)
No. of working sections (01-08)
Inlet plate UL17F / ... / UW1... 1.1
Inlet plate CL17
1.2
Inlet plate UL17
1.3
Inlet plate UL17F
1.4
Option block UD1, UW1...
Working section LS6F / ... / LW... 2.1
Working section B6
2.2
Working section LS6
. 2.3
Working section LS6F
. 2.4
Hydraulic operation HY
. 2.5
Electrohydraulic operation E1Y, EY, E
. 2.6
Spring cap
2.7
Option block LD1, LW..., LW1...
End plate ER2F / ... / E1C... 3.1
End plate ER1
3.2
End plate ER2
3.3
End plate ER27
3.4
End plate ER2F
3.5
Option block E1C
1.1
2.1
2.2
2.6
2.3
3.1
3.2
3.3
3.4
3.5
2.7
2.4
2.5
1.2
1.3
1.4
EN 5.282.2 / 10.20
6
Example of block specications and type code
TP
L S
M P
BA
M Y
BA
M Y
B
A
A
B
BA
M Y
B
A
A
B
L S
P C
Z
C
Example: control block for hydraulic system with variable displacement pump (CC system)
Type code Control block specication
Valve type LX-603
LX-6 with 3 working sections
LX-603 / B0 B0
BSPP connection type, valve series 0
Inlet plate CL17
Left hand inlet plate for CC systems,
w/o primary pressure limiter
CL17 / 300 / V2D 300
LS pressure relief valve set to 300 bar
V2D
LS unloading valve (normally open)
with 24 V solenoid and connector type Deutsch DT04-2P
Working section 1 B6
Basic section type w/o LS or workport valves
B6 / CS160-160RN / EYHS2D-1 / C1E
CS – RN
- Main spool type CS (closed in neutral position)
- Flow rate at working port A and B 160 l/min
- Pressure compensator with load holding function,
spring type N
EYHS2D-1
- Electrohydraulic operation and measuring port MY
- Hand lever axis and stroke limiter
- 24 V solenoid and connector type Deutsch DT04-2P
- Hand lever type 1
C1E
Spring cap for electrohydraulic operation
Working sections 2 and 3 LS6
Working section with LS and workport valves
LS6 / CR050-050RG / 200 – P / 250 – P / EYHS2D-1 / C1E
CR – RG
- Main spool type CR (unloaded in neutral position)
- Flow rate at working port A and B 50 l/min
- Pressure compensator with load holding function,
spring type G
200 – P
LS pressure limitation port A 200 bar, port B plug screw
250 – P
Shock valve port A 250 bar, port B plug screw
EYHS2D-1
- Electrohydraulic operation and measuring port MY
- Hand lever axis and stroke limiter
- 24 V solenoid and connector type Deutsch DT04-2P
- Hand lever type 1
C1E
Spring cap for electrohydraulic operation
End plate ER2
Right hand end plate with internal pilot oil supply
and external drained tank line
ER2 / 0 0
No options (standard)
EN 5.282.2 / 10.20
7
Inlet plate CL17
TP
LS
MP
Z
C
P
T
LX
LS
Type code
CL17 / 300 / V2D
1 2 3
1
2
3
TP
LS
M P
Z
C
P
T
LX
LS
TP
LS
M P
Z
C
P
T
LX
LS
TP
LS
M P
Z
C
P
T
LX
LS
CL17/_ _ _/_ _ _
CL17/P/P CL17/250/W2A CL17/300/P0A1D
1
Basic type
C
Closed Center system for variable displacement pump
L Left hand side
1
Version
7
Port size P / T
2
LS pressure relief valve
_ _ _
Pressure setting in bar,
3-digit, max. 350 bar
P
Plug screw
3
Option valve for LS circuit
1)
P
Plug screw
V
_ _
LS unloading
Normally open (Manual
emergency operation)
W
_ _
LS unloading
Normally closed (Manual
emergency operation)
P0A
_ _
Electro-proportional
pressure adjustment
Pressure stage A: 350 bar
12 V: I
max
= 1,500 mA
24 V: I
max
= 750 mA
!
The electro-proportional pressure relief valve P0A is
not suitable for acting as an LS unloading valve.
1)
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
Example congurations
CL17/P/P
l Basic type CL17
l w/o LS pressure relief valve (plug screw)
l w/o LS option valve (plug screw)
CL17/300/P0A1D
l Basic type CL17
l LS pressure relief valve set to 300 bar
l LS option valve type P0A, electro-proportional
pressure adjustment (pressure stage A: 350 bar)
l 12 V solenoid and connector type Deutsch DT04-2P
!
Unloading the LS circuit with the option valves V and W
3
will not block the ow to the working ports A and
B completely when the main spool is out of neutral position.
Regardless of viscosity or parallel operation, the working
pressure during blocking can be up to 15 bar depending
on the selected pressure compensator spring type.
For working sections without pressure compensator
(load holding function only), the stand-by pressure of the variable
displacement pump has to be taken into account.
1)
See section “Solenoid valves and coils”
EN 5.282.2 / 10.20
8
P
M P
LX
P
L1
Z
LS
T
L S
Z
C
P
T
LX
LS
Universal inlet plate UL17 / UL17F
p in bar
p in bar
Q in l/min
Q in l/min
Open Center circulation pressure P → T
Pressure relief function P → T
0 20 40 60 80 100 120 140 160 180 200 220 240 260
0 20 40 60 80 100 120 140 160 180 200 220 240 260
20
15
10
5
0
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
TP
L S
M P
Z
C
P
T
LX
LS
TP
LS
M
P
Z
C
P
T
LX
LS
Type code
UL17F / 300 / P / UW1V2D
UL17 / 250 / F
1 2 3 4
1
Basic type
U
Universal plate for OC and CC systems
L
Left hand side
1
Version
7
Port size P / T
F Flange interface for option blocks
2
Pilot pressure relief valve of main axis
_ _ _
Pressure setting in bar,
3-digit, max. 350 bar
P
Plug screw
3
Logic of main axis
F
3-way ow controller for xed displacement pump
P
Pump pressure relief valve
for variable displacement pump
4
Option block for basic type UL17F
Characteristic curves (measured at 32 mm²/s)
UL17/ _ _ _ / F
UL17F/ _ _ _ /P/...
UL17/ _ _ _ /P
Flange channels
Z Pilot drain
LS Load-sensing
L1 Load signal 1
P Pump
LX Load signal X
1)
1)
Separate, internal channel for optional functions
1
2
3 3 3
4
3
EN 5.282.2 / 10.20
9
Option blocks for inlet plate UL17F
LS
P
MP
LX
P
L1
Z
LS
T
L S
Z
C
T
P
LX
LS
LS
LX
P
L1
Z
LS
LS
LX
P
L1
Z
LS
Type code
UL17F / 300 / P / UW1V2D
UD1
UW1V_ _
UW1W_ _
UW1P0A_ _
Dummy plate
UD Basic type
1 Version 1
LX
P
L1
Z
LS
Flange channels
Z Pilot drain
LS Load-sensing
L1 Load signal 1
P Pump
LX Load signal X
LS option valves
1)
UW1 Basic type
V_ _
LS unloading
Normally open
(Manual emergency operation)
W_ _
LS unloading
Normally closed
(Manual emergency operation)
P0A_ _
Electro-proportional
pressure adjustment
Pressure stage A: 350 bar
12 V: I
max
= 1,500 mA
24 V: I
max
= 750 mA
!
The electro-proportional pressure relief valve P0A
is not suitable for acting as an LS unloading valve.
1)
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
!
Unloading the LS circuit with the option valves V and
W will not block the ow to the working ports A and B
completely when the main spool is out of neutral position.
Regardless of viscosity or parallel operation, the working
pressure during blocking can be up to 15 bar depending
on the selected pressure compensator spring type.
For working sections without pressure compensator
(load holding function only), the stand-by pressure of the
variable displacement pump or circulation pressure of the
xed displacement pump has to be taken into account.
1)
See section “Solenoid valves and coils”
Example congurations
UW1W2A
l Basic type UW1
l LS option valve type W, normally closed
l 24 V solenoid and connector type AMP Junior Timer
UW1P0A1D
l Basic type UW1
l LS option valve type P0A, electro-proportional
pressure adjustment (pressure stage A: 350 bar)
l 12 V solenoid and connector type Deutsch DT04-2P
EN 5.282.2 / 10.20
10
LS
LX
P
L1
Z
LS
P
MP
LX
P
L1
Z
LS
T
LS
Z
C
T
P
LX
LS
LS
UW1M_ _ _ V_ _UW1M_ _ _ W_ _
Option blocks for inlet plate UL17F
Switchable LS pressure limitation for LS circuit
1)
UW1M Basic type
_ _ _
Pressure setting in bar,
3-digit, max. 350 bar
V_ _
Normally open (Manual
emergency operation)
W_ _
Normally closed (Manual
emergency operation)
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
1)
See section “Solenoid valves and coils”
Example congurations
UW1M200W2A
l Basic type UW1M
l LS pressure relief valve set to 200 bar
l LS option valve type W, normally closed
l 24 V solenoid and connector type AMP Junior Timer
EN 5.282.2 / 10.20
11
BA
Z
C
P
T
LX
LS
(0 )
(a )
(b )
BA
Z
C
P
T
LX
LS
B
A
A
B
(0 )
(a )
(b )
BA
Z
C
P
T
LX
LS
Z LA LB LR LS
B
A
A
B
(0 )
(a )
(b )
B6 / ... LS6 / ... LS6F / ...
Working sections B6 / LS6 / LS6F
1
3
4
5
2
6 7
Type code
B6 / CR160-160RN / EYHS2D-1 / C1E
LS6 / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
Flange channels
Z Pilot drain
LA Load signal port A
LB Load signal port B
LR Load signal port A and B
LS Load-Sensing
(LS circuit)
1 2 3 4 5 6 7
1
Basic type
B6
Basic section type w/o LS pressure limitation
and workport valves
LS6
Working section with LS pressure limitation
and workport valves
LS6F
Working section with LS pressure limitation
and workport valves
Flange interface for option blocks
Port size 6 for working ports A / B
2
Main spool and pressure compensator
3
LS pressure limitation
4
Workport valves
5
Operation unit
6
Spring cap
7
Option block for basic type LS6F
EN 5.282.2 / 10.20
12
Main spool and pressure compensator
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
Examples
CR 160 - 160 R N
MS 180 - 180 L
2.1 Basic type of main spool
2.2 Max. ow at port A to actuator in l/min
2.3 Characteristic curve and overlap
2.4 Max. ow at port B to actuator in l/min
2.5 Basic type of pressure compensator / load holding function
2.6 Pressure compensator spring type
Cylinder as actuator
CS
4/3 directional valve closed in neutral position
CR
4/3 directional valve unloaded in neutral position
CT
4/3 directional valve closed in neutral position
20 bar return orice for A and B → T
to support system stability
CC
4/3 directional valve unloaded in neutral position
20 bar return line orice for port A and B → T
to support system stability
Regeneration function
RS
4/3 directional valve closed in neutral position
Regeneration function in spool position (a)
RR
4/3 directional valve unloaded in neutral position
Regeneration function in spool position (a)
Motor as actuator
MS
4/3 directional valve open in neutral position
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
P
T
A
B
2.1 2.2 2.42.3 2.5 2.6
Basic type of main spool
CS CR
RS
MS
CT
RR
CC
(b)
(0)
(a)
(b)
(0)
(a)
(b)
(0)
(a)
!
Other spool types and congurations on inquiry
EN 5.282.2 / 10.20
13
p in bar
CS
MS
Q (A/B) in l/min
Differential pressure A/B → T
Characteristic curves (measured at 32 mm²/s)
0 20 40 60 80 100 120 140 160 180 200
8
6
4
2
0
CS: Cylinder spool type – nominal control edge size: 08
MS: Motor spool type – nominal control edge size: 08
EN 5.282.2 / 10.20
14
Symmetrical spools
Max. ow rate to actuator in l/min (Port A - Port B) Pressure
compensator
Pressure com-
pensator spring
Type Type Identier
180 - 180 150 - 150 125 - 125 090 - 090 062 - 062 045 - 045 030 - 030 020 - 020 R Y Yellow
170 - 170 138 - 138 116 - 116 085 - 085 058 - 058 042 - 042 028 - 028 019 - 019 R W Blue
160 - 160 130 - 130 110 - 110 080 - 080 055 - 055 040 - 040 027 - 027 018 - 018 R N None
- - 100 - 100 072 - 072 050 - 050 036 - 036 025 - 025 016 - 016 R G Green
Nominal control edge size
08 - 08 07 - 07 06 - 06 05 - 05 04 - 04 03 - 03 02 - 02 01 - 01
Asymmetrical spools (on inquiry)
The main spool for asymmetrical ow rates can only be dened within one row in the table above.
The higher ow rate must be assigned to working port A (e.g. 160 – 130, 100 – 036, 150 – 090).
Characteristic curve and overlap
2.3
- Progressive/positive (standard)
Main spool and pressure compensator
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
CR 160 - 160 R N
2.1 2.2
2.2
2.3 2.4
2.4
2.5
2.5
2.6
2.6
Main spool ow range
Characteristic curves for nominal ow rates of main spool (measured at 32 mm²/s)
Example:
Max. ow to the actuator at working port A and B: 120 l/min
1. See table above: nominal control edge size 06 – 06 with pressure compensator spring Y → Q = 125 – 125 l/min
2. Setting to nal target value 120 l/min by stroke limiter
Q (A/B) in l/min
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
08
07
06
05
04
03
02
01
12 V: l in mA
24 V: l in mA
Hydraulic in bar
Stroke in mm
500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500
250 300 350 400 450 500 550 600 650 700 750
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10
EN 5.282.2 / 10.20
15
Flow control by section pressure compensator
Main spool and pressure compensator
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
CR 160 - 160 R N
2.1 2.2 2.3 2.4 2.5 2.6
A A
T TT T
P P
B B
2.12.6 2.5
Main spool in neutral position
(Type CR – A/B unloaded to T)
Main spool out of neutral position
(P → B, A → T)
P is not connected to the working ports A and B when the main spool
2.1
is in neutral position(Fig. A). The compensator spool
2.5
is moved to left against the compensator spring
2.6
by pump pressure and blocks ow to the main spool.
When the main spool
2.1
is operated out of the neutral position (Fig. B), the load pressure (LS pressure) of the working port A or B
is connected to the spring chamber of the pressure compensator and moves the compensator spool to the right into a corresponding
controlled position.
The ow rate through the main spool (= metering orice) is kept constant by the pressure compensator when sections are in parallel
operation with different load or pump pressures.
The characteristic ow rate curve of a main spool can be adapted and optimized to each application by using the different pressure
compensator spring types Y, B, N or G.
Basic types of pressure compensator / load holding function
R
Pressure compensator spool - released
with load holding function (standard type)
!
The load holding function is not
free of leak oil, the hydraulic
schematic / symbol is simplied
The pressure compensator R must always be
indicated in the type code with the corresponding
compensator spring type Y, B, N or G.
L Load holding function only
!
The load holding function is not
free of leak oil, the hydraulic
schematic / symbol is simplied.
Different load or pump pressures are not
compensated when sections are in parallel operation.
The ow rate to the actuator depends on the pressure
difference between pump pressure and load (LS pressure).
Main spool denition and detailed system setup on inquiry.
The pressure compensator spring
2.6
is not indicated
for the load holding function in the type code.
Example: MS180-180L
Q (A/B) in l/min
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 40 80 120 160 200 240 280 320 360
Pump pressure compensation (measured at 32 mm²/s)
Figure A Figure B
p (P - A/B) in bar
EN 5.282.2 / 10.20
16
LS pressure limitation
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
250 – P
3.1 3.2
Adjustable LS pressure limitation by blocking the sectional ow
rate to the working ports A and B.
For LS option valves and electro-proportional pressure adjustment,
see section “Option blocks for working section LS6F”.
BA
Z
C
P
T
LX
LS
B
A
A
B
3.1
3.2
Basic type
_ _ _
Pressure setting in bar, 3-digit
Minimum setting: 050 bar
Maximum setting: 320 bar
P
Plug screw
3.1 LS pressure limitation port A
3.2 LS pressure limitation port B
p (A/B) in bar
Q (A/B) in l/min
Load pressure compensation / limitation
(measured at 32 mm²/s)
0 40 80 120 160 200 240 280 320 360
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
!
The max. pressure setting in the inlet plate has to be
min. 20 bar higher than the LS pressure limitation
in the working section.
EN 5.282.2 / 10.20
17
Workport valves
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
300 – P
4.1 4.2
Basic type
_ _ _
Shock/ anti-cavitation valve
Pressure setting in bar, 3-digit (xed)
See table on next page for settings
A
Anti-cavitation valve
P
Plug screw
4.1 Workport valve port A
4.2 Workport valve port B
Fixed shock/anti-cavitation valves protect working ports A and
B against pressure peaks and cavitation. Anti-cavitation valves
protect the system against cavitation.
!
Shock/anti-cavitation valves are only for reduction of pressure
peaks and should not be used as pressure relief valves.
!
The setting for shock/anti-cavitation valves are xed ex works.
The pressure setting is dened at a ow rate of 10 l/min.
p (A/B) in bar
Q (A/B) in l/min
Shock function A/B → T
Characteristic curves (measured at 32 mm²/s)
0 10 20 30 40 50 60 70 80
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
BA
Z
C
P
T
LX
LS
B
A
A
B
4.1
4.2
!
In case of shock/anti-cavitation valves for all working
ports, the LS pressure relief valve in the inlet plate CL17 or
UL17/.../F has to be dened min. 20 bar below the highest
shock relief valve setting.
EN 5.282.2 / 10.20
18
Workport valves
Shock / anti-cavitation valve pressure settings (xed)
Settings bar 050 065 080 100 125 140 150 160 175 190 200 210 230 240 250 265 280 300 320 350 380
Tolerance range ± bar 5 5 5 5 7 7 7 7 10 10 10 10 10 10 10 12 12 12 12 12 15
Max. LS pressure cut-off bar - 050 060 080 105 120 120 130 145 160 170 180 200 210 220 235 250 270 290 320 320
(Min./max. LS pressure limitation setting: 050/320 bar)
Anti-cavitation function TA/B
p in bar
Characteristic curves (measured at 32 mm²/s)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
15
10
5
0
Q (A/B) in l/min
!
The maximum pressure setting for the shock/anti-cavitation
valves depends on the chosen pressure settings for the LS
limitations port A and B. To avoid interaction recommended
values are shown in the following table.
The values listed in the table are calculated according
to the following guidelines:
Shock valve setting p
shock
< 150 bar: p
shock
– p
LS
> 20 bar
Shock valve setting p
shock
150 bar: p
shock
– p
LS
> 30 bar
Operation units
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
E Y H S 2D - 1
H Y S
5.1 5.2 5.3 5.4
5.1 Basic type
5.2 Hand lever axis/main spool stroke limiter
5.3 Electrical supply voltage, connector type
5.4 Hand lever
HY
Unit for hydraulic operation:
Port X: spool position (a)
Port Y: spool position (b)
Pilot pressure measuring port MY: spool position (b)
E1Y
Unit for electrohydraulic operation, on/off:
orice setup 1 (orice 1,0 mm)
Pilot pressure measuring port MY: spool position (b)
EY
Unit for electrohydraulic operation, proportional:
Pilot pressure measuring port MY: spool position (b)
E
Unit for electrohydraulic operation,
proportional
( 0)
( a)
( b)
M YYX
( 0)
( a)
( b)
M Y
( 0)
( a)
( b)
M Y
Basic types 5.1
HY E1Y EY
S: Shock/ anti-cavitation valve
A: Anti-cavitation valve
A
S
EN 5.282.2 / 10.20
19
Operation units
General
Supply voltage V DC 12 24
Coil resistance
at 20 °C (±5%)
Ω 4.7 20.8
Duty cycle % 100
Connector type and IP protection class
(with mating connector mounted and locked)
AMP Junior Timer,
2-pin, axial
up to IP6K6
2)
Deutsch DT04,
2-pin, axial
up to IPX9K
2)
Protective screen µm 125
-
w/o hand lever axis – w/o stroke limiter
(n/a)
H Hand lever axis – w/o stroke limiter
S
Stroke limiter – w/o hand lever axis
HS
Hand lever axis – stroke limiter
Interface of hand lever axis and hand lever:
Hexagon WAF9
!
Stroke limiter must be used for the ne adjustment
of max. ow rates to the working ports A and B.
(see section “Main spool and pressure compensator”).
Dimension X for max. spool stroke:
See section “Dimensions”
- w/o hand lever (n/a)
1
Standard lever
2
Standard lever, short for emergency operation
3 Universal clamp without hand lever
3_ Universal clamp with hand lever (standard length)
Interface of hand lever axis and hand lever:
Hexagon WAF9
!
The hand lever is directly connected to the main spool
and follows the movement of the spool.
A hand lever can only be specied in combination with
a hand lever axis type H
5.2
.
( 0)
( a)
( b)
( 0)
( a)
( b)
( 0)
( a)
( b)
( 0)
( a)
( b)
Hand lever axis/main spool stroke limiter 5.2
Hand lever 5.4
Electrical supply voltage, connector type 5.3
H HSS
1_ 12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
!
Electrohydraulic operation can be overruled by
mechanical operation .
The hand lever is directly connected to the main spool
and follows the movement of the spool.
( 0)
( a)
( b)
1 / 2 / 3 / 3_
ca. 30°
19.5°
ca. 30°
Technical data for electrohydraulic pilot valves (on/off and proportional)
Pressure control valve (proportional)
Supply voltage V DC 12 24
Max. control current mA 1,500 750
PWM frequency
(recommended)
1)
Hz 100 ... 150
1)
The PWM frequency is to be optimized depending
on the application
2)
Mating plug-in connectors are not included
!
Standards ISO 13732-1 and ISO 4413 must be observed
in regard to the surface temperatures occurring on the coils.
EN 5.282.2 / 10.20
20
Operation units
Spring caps
Standard lever Standard lever, short
(Emergency operation)
Universal clamp
Universal clamp
with hand lever
1 2
31 32
3_
33
3
Left
3x M8x1.25 / 8 deep
Top Right
200
93
57
57
57
214
169.5169.5
Ø 25
Possible hand lever positions: see section “Dimensions”
Actuating torque on execution: - Hydraulic: min. 5 – 19 Nm
- Electrohydraulic: min. 3 – 19 Nm
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
C1 E
6.1 6.2
6.1
Basic type
C1
Type 1 (standard)
w/o pilot pressure measuring port MX:
spool position (a)
6.2
Main spool spring package
!
The spring package must be specied
according to the operation unit
5.1
.
H Hydraulic operation type HY
E
Electrohydraulic operation type E1Y, EY, E
( 0)
( a)
( b)
C1_
EN 5.282.2 / 10.20
21
Option blocks for working section LS6F
Z LA LB LR LS
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRV2D
LW R V 2D
7.1 7.2 7.3 7.4
Dummy plate
LD Basic type
1 Version 1
LS option valves
1)
!
Unloading the load signal or LS circuit with
the option valves V and W will not block the ow
to the working ports A and B completely
when the main spool is out of neutral position.
Regardless of viscosity or parallel operation, the
working pressure during blocking can be up to
15 bar depending on the selected pressure
compensator spring type.
7.1
Basic type LW
7.2
Flange channel
A Load signal port A
B Load signal port B
R Load signal port A and B
S Load-Sensing (LS circuit)
7.3
Solenoid valve
V
LS unloading
Normally open (Manual
emergency operation)
W
LS unloading
Normally closed (Manual
emergency operation)
P0A
Electro-proportional
pressure adjustment
Pressure stage A: 350 bar
12 V: I
max
= 1,500 mA
24 V: I
max
= 750 mA
!
The electro-proportional pressure relief valve P0A is
not suitable for acting as an unloading valve
1)
7.4
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
1)
See section Solenoid valves and coils
LD1
Flange channels
Z Pilot drain
LA Load signal port A
LB Load signal port B
LR Load signal port A and B
LS Load-Sensing
(LS circuit)
BA
Z
C
P
T
LX
LS
M Y
Z LA LB LR LS
B
A
A
B
Z LA LB LR LS
7.2 7.1
7.37.4
!
The LS option blocks can be used only in
combination with the sectional pressure
compensator type R
EN 5.282.2 / 10.20
22
Example congurations
LWRV2A
l Basic type LW
l Load signal port A and B
l LS option valve type V, normally open
l 24 V solenoid and connector type AMP Junior Timer
LWRP0A1D
l Basic type LW
l Load signal port A and B
l LS option valve type P0A, electro-proportional
pressure adjustment (pressure stage A: 350 bar)
l 12 V solenoid and connector type Deutsch DT04-2P
Z LA LB LR LS
Z LA LB LR LS
Z LA LB LR LS
Z LA LB LR LS
Z LA LB LR LS
Z LA LB LR LS
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LW1V-V2D
7.1
Basic type LW1
7.2
Solenoid valve for load signal port A
7.3
Solenoid valve for load signal port B
V
LS unloading
Normally open (Manual
emergency operation)
W
LS unloading
Normally closed (Manual
emergency operation)
7.4
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
LW1 V - V_ _
LW1 W - V_ _
LW1 V - W_ _
LW1 W - W_ _
LWRV2A LWRP0A1D
Option blocks for working section LS6F
!
The LS option blocks can be used only in
combination with the sectional pressure
compensator type R
LW1 V - V 2D
7.1 7.2 7.3 7.4
EN 5.282.2 / 10.20
23
Z LA LB LR LS
Z LA LB LR LS
Z LA LB LR LS
Option blocks for working section LS6F
Type code
LS6F / CR160-160RN / 250 – P / 300 – P / EYHS2D-1 / C1E / LWRM100-V2D
LW R M_ _ _ -V 2D
7.1 7.2 7.3 7.4 7.5
Switchable LS pressure limitation (2. pressure stage)
1)
7.1
Basic type LWM
7.2
Flange channel
A Load signal port A
B Load signal port B
R Load signal port A and B
S Load-Sensing (LS circuit)
7.3
LS pressure limitation
_ _ _ LS pressure setting in bar, 3-digit
Minimum setting: 050 bar
Maximum setting: 320 bar
7.4
Solenoid valve
V
Normally open (Manual
emergency operation)
W
Normally closed (Manual
emergency operation)
7.5
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D
Deutsch DT04-2P
1)
See section Solenoid valves and coils
Example congurations
LWBM200-V1A
l Basic type LWM
l Load signal port B
l LS pressure limitation set to 200 bar
l LS option valve type V, normally open
l 12 V solenoid and connector type AMP Junior Timer
LWSM250-W2D
l Basic type LWM
l Load-Sensing (LS circuit)
l LS pressure limitation set to 250 bar
l LS option valve type W, normally closed
l 24 V solenoid and connector type Deutsch DT04-2P
LWBM200-V1A
LWRM_ _ _-V_ _
LWSM250-W2D
7.1
7.3
7.5
7.2
!
The LS option blocks can be used only in
combination with the sectional pressure
compensator type R
7.4
EN 5.282.2 / 10.20
24
End plates
Z
C
P
T
LX
LS
LS
Z
C
LS
PC
Z
C
P
T
LX
LS
Z
C
LS
PC
Z
C
P
T
LX
LS
Z
C
P
T
PC
Z
C
P
T
LX
LS
C
CX
Z
LS
Z
C
ER1 ER2/0 ER27/0 ER2F/0/...
1.2 1.2
1.3
1.3
1.1
Type code
ER1 ...
ER2 ... / 0
ER27 ... / 0
ER2F ... / 0 / E1C2D / *
ER 1
ER 2 F
Flange channels
C Pilot oil
CX Pilot oil X
Z Pilot drain
1 2 3 4 5
1
Basic type
1.1
ER
End plate, right hand side
1.2
1
w/o or external pilot oil supply
2 Internal pilot oil supply (channel P)
1.3
7
Port size P / T
F Flange interface for option blocks
2
Conguration
1)
3
Options
1)
4
Option block for basic type ER2F
5
Reference to clear text
Special, customer-specic information
1.1 1.2 1.3
1)
Can also be retrofitted
EN 5.282.2 / 10.20
25
End plate ER1
End plates ER2, ER27, and ER2F
Z
C
P
T
LX
LS
LS
Z
C
Z
C
P
T
LX
LS
LS
Z
C
Z
C
P
T
LX
LS
LS
Z
C
LS
PC
Z
C
P
T
LX
LS
Z
C
LS
PC
Z
C
P
T
LX
LS
Z
C
P
T
Type code
Type code
ER1 ...
ER2 ... / 0
1
1
2
2 3
1
Basic type
ER1
End plate, right hand side
w/o or external pilot oil supply
2
Conguration
- Standard (n/a)
2.1
Z
Internal connection Z → T with check valve
Port Z with plug screw
!
For conguration Z, the max. permitted operating
pressure at port T is 10 bar.
2.2
E
External LS signal input
Port LS open
Internal LS-unloading with plug screw
2.3
C
Port C with plug screw
w/o pilot oil supply for manual and hydraulic
operation units only
The individual congurations Z, E and C can be combined
as follows: ZE, ZC, EC, ZEC
1
Basic type
ER2
End plate, right hand side
Internal pilot oil supply (channel P)
ER27
Same as ER2, with additional P / T ports
Port size 7
ER2F
Same as ER2, with ange interface
for option blocks
2
Conguration
Standard (n/a)
2.1
Z
Internal connection Z → T with check valve
Port Z with plug screw
!
For conguration Z, the max. permitted operating
pressure at port T is 10 bar.
2.2
E
External LS signal input
Port LS open
Internal LS-unloading with plug screw
The individual congurations Z and E can also
be combined: ZE
ER1
ER2/...
ER1Z
ER27ZE/...
ER1ZEC
Example congurations
ER1
l Basic type ER1
l Standard conguration
ER1Z
l Basic type ER1
l Internal connection Z → T with check valve
Port Z with plug screw
Example congurations (Options
3
see next page)
ER2/...
l Basic type ER2
l Standard conguration
ER27ZE/...
l Basic type ER27
l Internal connection Z → T with check valve
Port Z with plug screw
l External LS signal input, Port LS open
Internal LS-unloading with plug screw
2.1
2.1
2.3
2.2
2.2
2.2
2.2
2.1
2.1
EN 5.282.2 / 10.20
26
End plate ER2
Option blocks for end plate ER2F
Z
C
PC
Z
C
LS
PC
Z
C
P
T
LX
LS
Z
C
Z
Z
C
PC
Z
C
P
T
LX
LS
C
CX
Z
LS
Z
C
CX
Type code
ER2 ... / 0
1 2 3
3
Options at port PC and C
0
w/o options (standard)
Port PC and C with plug screw
PC
Z
C
Z
C
3.1
Options at port PC
(Port C with plug screw)
P1
Cut-off valve, mechanical with knurled screw
!
Port PC not usable.
Operation of cut-off valve < 50 bar system pressure.
P2
Check valve
Port PC with plug screw
3.2
Options at port C
(Port PC with plug screw)
C1 Cut-off valve, mechanical with knurled screw
!
Port C not usable.
C2
Check valve
Port C with plug screw
The individual options can be combined as follows:
P1C2, P2C1, P2C2
Example: ER2/P1C2
Pilot oil option valve
1)
E1 Basic type
C_ _
Pilot oil unloading
Normally open
(Manual emergency operation)
Solenoid (supply voltage, connector type)
1_
12 V
2_
24 V
_A
AMP Junior Timer
_D Deutsch DT04-2P
P1
P2 C2
E1C _ _
ER2/... C1
3.2
3.1
Type code
ER2F ... / 0 / E1C2D
1)
See section Solenoid valves and coils
EN 5.282.2 / 10.20
27
Solenoid valves and coils
Electrohydraulic pilot valves (on/off and proportional): see section “Operation units”
Option valves for connecting plate CL17 and option blocks:
On/Off valves:
With manual emergency operation (push-button)
Valve type V W C
Design Poppet valve Poppet valve Spool valve
Nominal voltage U
N
V DC 12 24 12 24 12 24
Nominal current I
N
A 1.50 0.80 2.20 1.10 1.50 0.80
Min. current I
min
A 1.05 0.56 1.54 0.77 1.05 0.56
Nominal power P
N
W 18 19 26 26.7 18 19
Response time On: ms 40 30 85
Off: ms 60 40 80
Max. permitted voltage deviation from U
N
% ±15
Duty cycle at 115% U
N
% 100
Ambient temperature range
2)
°C -20 to +60
Max. permitted coil temperature
3)
°C 180
Insulation class as per EN 60085 H
Integrated free-wheeling diode Yes Yes Yes
Coil length X mm 40 50 40
Connector type and IP protection class
(with mating connector mounted)
AMP Junior Timer, 2-pin – axial / up to IP6K6
4)
Deutsch DT04, 2-pin – axial / up to IPX9K
4)
Valve body and coil surface protection Zinc-Nickel (ZnNi)
Proportional pressure relief valve: bleed
screw below coil nut (torque 2.5 + 0.5 Nm)
Valve type P_ _
Nominal voltage U
N
V DC 12 24
Coil resistance at +20 °C (±5%) Ω 4.1 17.6
Max. control current I
max
mA 1,500 750
PWM frequency (recommended)
1)
Hz 150 – 200
Duty cycle at I
max
% 100
Ambient temperature range
2)
°C -20 to + 60
Max. permitted coil temperature
3)
°C 180
Insulation class as per EN 60085 H
Coil length X mm 50
Connector type and IP protection class (with mating connector mounted)
AMP Junior Timer, 2-pin – axial up to IP6K6
4)
Deutsch DT04, 2-pin – axial up to IPX9K
4)
Valve body and coil surface protection Zinc-Nickel (ZnNi)
!
In order to achieve optimal function, any trapped air should
be vented with the bleed screw. Recommended installation
position downwards (suspended for self-ventilation)
12 V: l in mA
24 V: l in mA
p (A/B) in bar
Characteristic curve (measured at 32 mm²/s)
LS pressure limiting function p/l (rising curve)
400 500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500
200 250 300 350 400 450 500 550 600 650 700 750
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
1)
The PWM frequency is to be optimized depending on the application
2)
Deviation of data on inquiry only
3)
Standards ISO 13732-1 and ISO 4413 must be observed in regard
to the surface temperatures occurring on the coils
4)
Mating plug-in connectors are not included
AMP Junior Timer, axial Deutsch DT04, axial
Ø36.5 X
XØ36.5
!
The electro-proportional pressure relief valve P_ _
is not suitable for acting as an LS unloading valve.
EN 5.282.2 / 10.20
28
Connection type, fastening and tie rods
Type code
LX-6 03 / B 0
1 2 3 4
1
Valve type
2
Specication type
_ _
Complete control block
No. of working sections (01-08)
0X
Single modules
(inlet plate, working section,
end plate, option block)
3
Connection type
B BSPP acc. to ISO 1179-1
S SAE acc. to ISO 11926-1 or SAE J1626
4
Valve series
!
Only use of ttings with deformable seal materials
Connection type B
Countersink
Ø in mm
S
Countersink
Ø in mm
Inlet plate CL17 P Pump G 1 50 1 5/16-12 UN SAE 16 49
UL17 T Tank G 1 50 1 5/16-12 UN SAE 16 49
UL17F MP Pump measuring port G 1/4 25 9/16-18 UNF SAE 6 25
LS Load-sensing G 1/4 25 9/16-18 UNF SAE 6 25
Working section B6 A/B Working ports G 3/4 38 1 1/16-12 UN SAE 12 38
LS6 X Hydraulic operation port
(spool position a)
G 1/4 25 7/16-20 UNF SAE 4 21
LS6F Y Hydraulic operation port
(spool position b)
G 1/4 25 7/16-20 UNF SAE 4 21
MY Pilot pressure measuring port
(spool position b)
G 1/8 15 G 1/8 - 15
End plate ER1 PC Pump measuring port (for options) G 1/4 25 9/16-18 UNF SAE 6 25
ER2 C Pilot oil supply G 1/4 25 9/16-18 UNF SAE 6 25
ER27 Z Tank, depressurized G 1/4 25 9/16-18 UNF SAE 6 25
ER2F LS External Load-Sensing input G 1/4 25 9/16-18 UNF SAE 6 25
P Pump G 1 50 1 5/16-12 UN SAE 16 49
T Tank G 1 50 1 5/16-12 UN SAE 16 49
Option blocks UW1… LS Load-sensing G 1/4 25 9/16-18 UNF SAE 6 25
E1C… CX Pilot oil supply X G 1/4 25 9/16-18 UNF SAE 6 25
Fastening:
The control block must be mounted at three xation points without tensioning. see also section “Dimensions”
Fastening thread B S
Inlet plate CL17
2 x 13 mm deep M10x1.5 7/16-20 UNF SAE 4UL17
UL17F
End plate ER1
1 x 13 mm deep M10x1.5 7/16-20 UNF SAE 4
ER2
ER27
ER2F
Installation, usage, and maintenance information
Installation, adjustment, maintenance must be done by authorized and trained staff.
The use of this product outside the specied technical limits, use of non specied uids and/or
use of not genuine spare parts will cause the expiration of the warranty.
Fastening screws:
l Minimum screw-in depth: 10 mm
l Recommended screw clamp length: ≥30 mm
Property class 10.9
Fastening torque Nm 72
±3
Tie rod:
M10 tie rod with ange nut WAF 16, M
Z
= 40 ±2 Nm
!
Only use of genuine LX-6 tie rod kits.
EN 5.282.2 / 10.20
29
Dimensions
112
All dimensions in mm, subject to change.
Example for control block with Closed Center inlet plate and end plate with P/T ports (see also section “Modular structure”)
Connector types: Deutsch DT04, 2-pin, axial
1.1
Inlet plate CL17
2.1
Working section B6
2.2
Working section LS6
2.3
Working section LS6F
2.4
Hydraulic operation HY
2.5
Electrohydraulic operation E1Y, EY, E
2.6
Spring cap C1E
2.7
Option block LW.../LW...M...
1)
3.3
End plate ER27
LA
LS pressure limitation port A
LB
LS pressure limitation port B
SA
Secondary valves port A
SB
Secondary valves port B
4.0
Type plate
4.1
3x M10x1.5 – 12 deep for crane gear
1)
Option block LW1... not shown
276
51.5
110.5
337
112
92.5
52
51 105
28.5
28.5
32.5
217
86
119.548
16
26
24
18
13.5
144 48.5
17.5
30
258
31
31
123.5
54.5
26.5
186
20.5
27.5
48 23.5
91
2.72.3 3.3
SA
LA
4.1 4.1
2.6
4.1LB
SB
2.42.5
4.0
2.22.11.1
MY
LS pressure relief valve
Standard lever, short
(Emergency operation)
Pilot valve
port B
Pilot valve
port A
Stroke limiter port A (Dimension X for max. stroke: 25)
clockwise rotation for limitation
Stroke limiter port B (Dimension X for max. stroke: 13)
counterclockwise rotation for limitation
MY
X
EN 5.282.2 / 10.20
30
Dimensions
307
3x 48 = 14431
31123.5
175
48.5
51.5
Pilot pressure relief valve
of main axis
2474
44
23.548
27.5 13.5
112
307
276
92.5
52
5191
28.5
20
86.5
86
17.5
119.5
20.5
30.5
206
99.5
28.5
17.5
All dimensions in mm, subject to change.
Example for control block with universal inlet plate and option blocks (see also section “Modular structure”)
Connector types: AMP Junior Timer, 2-pin, axial
1.3
Inlet plate UL17F
1)
1.4
Option block UW1...
2.1
Working section B6
2.2
Working section LS6
2.3
Working section LS6F
2.5
Electrohydraulic operation E1Y, EY, E
2.6
Spring cap C1E
2.7
Option block LW.../LW...M...
2)
3.4
End plate ER2F
3)
3.5
Option block E1C...
4.0
Type plate
4.1
3x M10x1.5 – 12 deep for crane gear
1)
Inlet plates UL17F and UL17 have the same dimensions
2)
Option block LW1... not shown
3)
End plates ER2F, ER2, and ER1 have the same dimensions
3.5
3.42.72.32.22.11.31.4
4.1
4.1
2.5
MY
4.0
MY
2.6
EN 5.282.2 / 10.20
31
Dimensions
All dimensions in mm, subject to change.
Hand lever: neutral positions and max. travel (see also section “Operation units”)
Control block fastening points (3x M10x1.5 – 13 deep)
The fastening points are equal for all types of inlet and end plates
Neutral positions: for all hand lever types 1 – 3: Max. travel for port A / port B
ca. 30°
43.5°
80°
ca. 30°
19.5°
19.5°
L1
159
port B
port A
25
48
106.5 16.5
58.5
Shown: Standard lever, short (emergency operation) – Type 2
No. of working sections 1 2 3 4 5 6 7 8
L1 mm 88 136 184 232 280 328 376 424
EN 5.282.2 / 10.20
32
Type code
Structure and sequence: 1. General (control block always dened from left to right)
2. Inlet plate
3. Working section 1
Working section 2
Working section n
4. End plate
1. General
Valve type: LX-6 03 / B 0
Pos. 1 2 3 4
Pos./designation: Type code: Description/function Comment:
1 Load-sensing valve series LX-6 Load-sensing X-series Size 6
2 No. of working sections
Specication/identication of single modules
1) _ _ 2-digit, 01–08 Max. 8 working sections
0X Inlet plate, working section, end plate or option block
3. Connection thread
B BSPP acc. to ISO 1179-1
S SAE acc. to ISO 11926-1 or SAE J1626
4 Valve series 0 Unchanged installation and connection dimensions
2. Inlet plate
Type: CL17 / P / V2D
UL17 / 250 / F
UL17F / 350 / P / UW1V2A
Pos. 1 2 3 4
Pos./designation: Type code: Description/function Comment:
1 Basic type
Standard for variable displacement pump CL17 CC system Left 1 version 7 port size P/T Port size 7:
Universal for xed
and variable displacement pump
UL17 Universal Left 1 version 7 port size P/T BSPP: G1; SAE: 1 5/16-12 UN
Universal like UL17 with option block UL17F Flange interface for option block
2 Pressure relief valve
_ _ _ Pressure setting in bar, 3-digit (mechanically adjustable) Max. 350 bar
P Plug screw w/o pressure relief valve
3 LS option valves
!
For basic type CL17 only
P Plug screw w/o LS option valve
V _ _ LS unloading Valve type: V Normally open
W _ _ LS unloading Valve type: W Normally closed
P0A _ _
Electro-prop. pressure adjustment Valve type: P
Orice setup: 1.0 mm Pressure stage A: 350 bar
Rising curve
Supply voltage DC
1 _ 12 V
2 _ 24 V
Connector type
_ A AMP – Junior Timer, 2-pin, axial
_ D Deutsch – DT04, 2-pin, axial
Logic of main axis
!
For basic types UL17 and UL17F only
F Flow controller (3-way) For xed displacement pump
P Pump pressure relief valve (pilot-operated) For variable displacement pump
4. Option blocks
!
For basic type UL17F only UD1 Dummy plate 1 version
For logic of main axis F or P
For channel:
L1 Load signal 1
UW1V _ _ LS unloading L1 channel Valve type V Normally open
UW1W _ _ LS unloading L1 channel Valve type W Normally closed
UW1P0A _ _
Electro-proport. press. adjust. L1 channel Valve type P
Orice setup: 1.0 mm Pressure stage A: 350 bar
Rising curve
UW1M _ _ _ V _ _
Second pressure stage L1 channel Valve type V
(On/Off) Mechanically adjust. in bar, 3-digit
Second pressure level when de-energized
UW1M _ _ _ W _ _
Second pressure stage L1 channel Valve type W
(On/Off) Mechanically adjust. in bar, 3-digit
Second pressure level when energized
Supply voltage DC
1 _ 12 V
2 _ 24 V
Connector type
_ A AMP – Junior Timer, 2-pin, axial
_ D Deutsch – DT04, 2-pin, axial
1)
Deviation of data on inquiry only
EN 5.282.2 / 10.20
33
3. Working sections
Type Working section 1 B6 / CR 160 – 160 RN / EYHS2A - 1 / C1E
Working section 2 LS6 / CS 150 – 035 RN / 300 – 200 / P – P / EYHS2A / C1E
Working section 3 LS6F / CR 060 – 060 RY / 300 – 300 / 350 – 350 / HYHS - 1 / C1H / LWRV2A
Working section 4 / / / ...
Pos. 1 2 3 4 5 6 7 8 9 10
Pos./designation: Type code: Description/function Comment:
1. Basic type
Basic section w/o option valves B6 Basic section 6 port size A/B Port size 6:
Section like B6 with option valves LS6 Like B6 with LS pressure limitation and Shock/anti-cavitation valves BSPP: G3/4, SAE: 1 1/16-12 UN
Section like LS6 with option block LS6F Like LS6 with Flange interface for option block
2 Main spool
CS Cylinder spool Standard Pos. 0: A, B closed
CR Cylinder spool Released Pos. 0: A, B unloaded to T
MS Motor spool Standard Pos. 0: A, B open to T
...
For other types, see section
“Main spool and pressure compensator”
3 Max. ow rate to actuator A B
See section “Main spool valve
and pressure compensator”
1) _ _ _ - _ _ _ Maximum ow to port A / B in l/min, 3-digit
4 Pressure compensator axis (spool + spring)
Pressure compensator – released
with load holding function (standard)
RY Released pressure compensator Y spring identier yellow 9.5 – 11.5 bar
RB B spring identier blue 8.0 – 10.0 bar
RN N spring identier unmarked 7.0 – 9.0 bar (nominal)
RG G spring identier green 5.5 – 7.5 bar
Load holding function L Load holding function only w/o pressure compensation Use of compensator spring type G
5. LS pressure limitation A B
!
For basic types LS6 and LS6F only
_ _ _ - _ _ _ Pressure setting for port A / B in bar, 3-digit (mechanically adjustable) Min. 050 bar, max. 320 bar
P Plug screw w/o LS pressure limitation
U Unloading - permanent 3/3 directional valve function
6 Workport valves A B
!
For basic types LS6 and LS6F only
_ _ _ - _ _ _ Shock/anti-cavitation valve for port A / B in bar, 3-digit See section “Workport valves”
A Anti-cavitation valve
P Plug screw
w/o workport valves
7 Operation units
HY H hydraulic MY port Pilot pressure MY – spool position (b)
E1Y E1 electrohydraulic on/off, orice setup 1 MY port orice 1.0 mm
EY E electrohydraulic proportional MY port
Other options:
n/a w/o hand lever axis - w/o stroke limiter
_ H Hand lever axis
_ S Stroke limiter
_ HS Hand lever axis and Stroke limiter
!
For operation unit E... only
Supply voltage DC
1 _ 12 V
2 _ 24 V
Connector type
_ A AMP – Junior Timer, 2-pin, axial
_ D Deutsch – DT04, 2-pin, axial
8. Hand lever type
Hand lever does not come assembled
!
For operation option _H only n/a No hand lever
Standard lever 1 Standard See section “Operation units”
Standard lever, short
2 Standard for emergency operation
Universal clamp without hand lever
3 For application-specic solutions
Universal clamp with standard lever
31 Lever orientation: left
32 Lever orientation: top
33 Lever orientation: right
9. Spring caps
Standard for operation unit H... C1H C standard cap 1 version H hydraulic Pilot pressure range: 6.5 – 20 bar
Standard for operation unit E...
C1E C standard cap 1 version E electrohydraulic Pilot pressure range: 4.5 – 20 bar
Type code
1)
Deviation of data on inquiry only
EN 5.282.2 / 10.20
34
10 Option blocks
!
For basic type LS6F only
For channel:
LA Load signal port A
LB Load signal port B
LR Load signal port A and B
or
LS Load Sensing
(LS circuit)
LD1 Dummy plate 1 version
LW _ V _ _
LS unloading LWA, LWB, LWR or LWS channel
Valve type V
Normally open
LW _ W _ _
LS unloading LWA, LWB, LWR or LWS channel
Valve type W
Normally closed
LW _ P0A _ _
Electro-prop. pres. adj. LWA, LWB, LWR or LWS channel
Orice setup: 1.0 mm Pressure stage A: 350 bar Valve type P
Rising curve
LW _ M _ _ _ V _ _
Second pressure stage LWA, LWB, LWR or LWS channel
(On/Off) Mech. adjustable in bar, 3-digit Valve type V
Second pressure level
when de-energized
LW _ M _ _ _ W _ _
Second pressure stage LWA, LWB, LWR or LWS channel
(On/Off) Mech. adjustable in bar, 3-digit Valve type W
Second pressure level
when energized
For channel:
LA and LB
LW1 V - V _ _
LW1 basic type Load signal port A - Load signal port B
Valve type V – normally open Valve type W – normally closed
Valve type V and W selected
as desired
Supply voltage DC
1 _ 12 V
2 _ 24 V
Connector type
_ A AMP – Junior Timer, 2-pin, axial
_ D Deutsch – DT04, 2-pin, axial
4. End plate
Type:
ER2 / 0
ER2F ZE / 0 / E1C2A / *
Pos.
1 2 3 4 5
Pos./designation: Type code: Description/function Comment
1 Basic type
Standard with/without external pilot oil supply ER1 End plate Right 1 external pilot oil supply
Standard with internal pilot oil supply ER2 2 internal pilot oil supply from channel P
End plate like ER2 with ports P/T ER27 7 port size P/T
Port size 7:
BSPP: G1; SAE: 1 5/16 - 12 UN
End plate like ER2 with option block ER2F F ange interface for option block
2 Conguration
For all basic types
For ports: Z, LS
n/a Standard External depressurized drain line to Tank
No external LS signal input
Port Z open
Port LS closed
Z Internal connection Z → T with check valve Port Z closed
E External LS signal input / internal LS-unloading with plug screw Port LS open
For basic type ER1 only C w/o external pilot oil supply for manual and hydraulic operations only Port C closed
3 Options
!
For basic type ER2... only
For ports: PC and C
0 Standard w/o options Ports PC and C closed
P1 Port PC: Cut-off valve, mechanical with knurled screw Port PC not usable
P2 Port PC: Check valve Port PC closed ex works
C1 Port C: Cut-off valve, mechanical with knurled screw Port C not usable
C2 Port C: Check valve Port C closed ex works
4 Option blocks
!
For basic type ER2F only E1C _ _ E1 Basic type Pilot oil unloading Valve type C Normally open
Supply voltage DC
1 _ 12 V
2 _ 24 V
Connector type
_ A AMP – Junior Timer, 2-pin, axial
_ D Deutsch – DT04, 2-pin, axial
5 Reference to clear text * Special, customer-specic information / data in attached clear text
Type code
EN 5.282.2 / 10.20
35
LS
PC
Z
C
P
T
BAMYYX
Z
L
A
LB
LR
LS
B
A
A
B
BA
MY
B
A
A
B
BA
MY
TP
LS
MP
Z
C
P
T
LX
LS
BA
MY
B
A
A
B
BA
MY
Z
C
P
T
LX
LS
P
MP
LX
P
L1
Z
LS
T
LS
LS
BAMY
Z LA LB LR LS
B
A
A
B
PC
C
CX
Z
LS
Z
C
CX
Ordering examples
General LX-603/B0
Inlet plate CL17/300/V1D
Working section 1 B6/MS100-100RG/E1YHS1D-2/C1E
Working section 2 LS6/CS160-160RN/P - 200/A - 250/EYHS1D-2/C1E
Working section 3 LS6F/CR135-040RB/250 - 250/280 - 280/HYHS-2/C1H/LWAV1D
End plate ER27/C2
General LX-603/B0
Inlet plate UL17F/300/F/UW1V2A
Working section 1 B6/CS070-070RG/EYHS2A/C1E
Working section 2 LS6/CC160-055RN/P - P/350 - 350/EYHS2A/C1E
Working section 3 LS6F/CT150-150RY/250 - 250/P - P/EYHS2A/C1E/LWRP0A2A
End plate ER2FE/0/E1C2A
Example for control block with Closed Center inlet plate and end plate with P/T ports
(see also section “Dimensions”)
Example for control block with universal inlet plate and option blocks (see also section “Dimensions”)
EN 5.282.2 / 10.20
36
Note
The information in this brochure
relates to the operating conditions
and applications described.
For applications and operating conditions
not described. please contact the relevant
technical department.
Subject to technical and other changes.
Head Ofce Industriegebiet
HYDAC INTERNATIONAL 66280 Sulzbach/Saar
GMBH Germany
Tel.: +49 6897 509-01
Fax: +49 6897 509-300
E-mail: mobilevalves@hydac.com