EN 5.249.23.4/05.22
3
Control types – Pilot supply and pilot
drain
If the valve is used as a hydraulically
actuated valve, the pilot supply and pilot
drain will occur external via port X and Y.
If the valve is used as the main stage
in a pilot-operated valve, there are four
possible control types for each basic
valve. This can be seen in the model
code.
The valve will be delivered
correspondingly congured. Modication
is possible afterwards. The glued
threaded plugs will make disassembly
more dicult.
FUNCTION
The valves of the 4WH 25 series are
directional spool valves with hydraulic
operation which can control the start,
stop and direction of a volume ow.
They consist of the valve casing (1), the
main control spool (2) and the return
springs (3).
The uid power supply of the valve
is provided centrally via the standard
porting pattern.
Without pilot oil, the main control
spool is centred in its middle position
by the springs. The actuation of the
main control spool (2) is caused by
pressurisation. The required pilot
oil is provided by port X and Y or is
controlled by an additional pilot valve
that is adopted to the main valve. The
pilot pressure depends on rate of ow.
The minimal pilot pressure of 5 bar is
sucient only for low ow rates. Pilot
pressure has to be increased up to 12
bar by increasing rates of volume ow.
Pressure loading on one of the two
front sides of the main control spool
(2) with pilot pressure causes desired
switching position, whereby the required
ports will be linked. The spring, which
is across from the pressurised control
piston surface, causes the resetting of
the piston into zero or initial position by
relieving of pressure.
SECTION VIEW
z Version "E" –
Pilot supply is external from a
separate uid power supply via port
X. The pilot drain is also external via
port Y.
z Version "EI" –
Pilot supply is external from a
separate uid power supply via port
X. The pilot drain is internal via port T.
z Version "IE" –
Pilot supply is internal via port P. The
pilot drain is external via port Y.
Hint: Symbols G and H only with
option G.
z Version "I" –
Pilot supply is internal via poer P. The
pilot drain is external via port T.
Hint: Symbols G and H only with
option G.