EN 5.201.3/02.22
4
FUNCTION
The solenoid-operated directional
poppet valves of type WSE 6 are used
to control a ow. The valve design
is patented and consists of a valve
casing (1) and depending on the type,
one or more poppet-seat elements
(2). Depending on the type, the valve
is equipped with one or more return
springs (3) and with one or two pole
tubes (4) and solenoid coils (5) each.
The hydraulic control of the valve is
carried out through the actuation of the
valve spool by the use of solenoids (5).
A solenoid is a converter, which converts
electrical energy into mechanical energy.
The energized solenoid causes the
oil-immersed magnetic piston to make
a linear stroke movement. It uses the
guide rod (6) to move the poppet-seat
elements into the desired position. This
causes the nominal ow directions
between the respective ports to be
released or seat-tight closed.
The modular principle of the key
components enables a large variety of
switching congurations. Consequently
these valves can be used as a leak-free
alternative to spool valves. The special
grounded poppet-seat elements are
pressure-equalised and with it double-
tight, i.e. pressure reversals (within the
permitted port pressures) do not result in
undesired opening.
To obtain the valves’ optimum switching
capacity, the pressure-tight chamber
of the pole tube should always be lled
with oil. The poppet-seat element is
pushed back into the starting position by
the appropriate return spring after de-
energization of solenoid.
The manual override (7) enables
valve operation without energising the
solenoid.
TECHNICAL DATA
1)
General performance data
MTTF
d
: According to EN ISO 13849-1:2016
Table C1
Ambient temperature: [°C] -20 to +60
Installation position: No orientation restrictions
Weight: [kg] 1.7 with one solenoid;
2.2 with two solenoids
Material: Valve casing: Steel
Pole tube: Steel
Coil casing: Steel
Name plate: Aluminium
Surface coating: Valve casing: Phosphate plated
Pole tube: Zn-coating
Coil casing: ZnNi-coating
Hydraulic specications
Operating pressure: [bar] Port A, B, P: p
max
= 350
Port T: p
max
= 70
Nominal ow: [l/min] 25
Operating uid: Hydraulic oil to DIN 51524 Part 1, 2 and 3
Media operating temperature range: [°C] -20 to +80
Viscosity range: [mm²/s] 10 to 500
Permitted contamination level
of operating uid:
Class 20/18/15 according to ISO 4406
Max. switching frequency: [1/h] 3,600
Manual override: Up to approx. 50 bar tank pressure available
Sealing material: FKM
Electrical specications
Switching time: [ms] See table, page 4
Type of voltage: DC
Rated voltage: [V] 24
Voltage tolerance: [%] ±10
Nominal power: [W] 30
Duty cycle: [%] 100
Max. surface temperature of the coil: [°C] 150
Protection class according to DIN EN 60529: with electrical connection “G” IP65
2)
1)
see “Conditions and Instructions for Valves” in brochure 53.000
2)
if installed correctly
SECTION VIEW
Non-return valve
Closes port P to prevent reverse oil ow.
Orice insert
Used to reduce nominal ows that are too high and outside of
the valve’s operating limits.