2
E 7.577.2/11.16
EMLF40 ON 660 N4 005 B X / -V
Filter type
EMLF40 40 bar
Filter material
ON Optimicron
®
BN/HC Betamicron
®
(BN4HC) only to be used for water-glycol applications with "-SS-SO361"!
BN/AM Betamicron
®
/Aquamicron
®
(BN4AM)
ECO Ecomicron (ECON2) W/HC wire mesh
Size of lter
330, 660
Type and size of connection
Type Port
(thread)
Filter size
330 660
B4 1"-BSPP
B5 1¼"-BSPP
N4 1"-NPT
N5 1¼"-NPT
F32 SAE 32
Filtration rating in µm
ON : 001, 003, 005, 010, 015, 020 BN/HC (/-SS-SO361) : 003, 010
ECO : 003, 005, 010, 020 BN/AM : 003, 010
W/HC : 025, 050, 100, 200
Type of clogging indicator
W without port (no clogging indicator)
A stainless steel blanking plug in indicator port
B visual
C electrical
for other clogging indicators
D visual and electrical
see brochure no. 7.050../..
UE vacuum gauge
BM+C visual with manual reset + electrical (= 2 indicators)
E 1/4"-NPT gauge ports for external connection of pressure sensors
Modication number
X the latest version is always supplied
Supplementary details
B. bypass cracking pressure (e.g. B6 = 6 bar); without details = without bypass valve
EX electrical clogging indicator EX version (Eexd IIC T6; cable length 0.25 m standard)
EX/ENC electrical clogging indicator EX version (Eexd IIC T6; with IP66 junction box, M20x1.5 cable entry)
IS intrinsically safe electrical clogging indicator with cable length 0.25 m (standard)
IS/ENC intrinsically safe electrical clogging indicator with IP66 junction box (M20x1.5 cable entry)
IS2GBC intrinsically safe electrical clogging indicator with gold contacts (e. g. suitable for PLC)
L... lamp with appropriate voltage (24, 48, 110, 220 volts) only for clogging indicators
LED 2 light emitting diodes up to 24 Volt type "D"
N NBR seals
V FPM seals
NLT nitrile low temperature seals
HNBR hydrogenated nitrile (high temperature) seals
EPDM EPDM seals
K Kalrez
®
seals
SS-SO361
stainless steel elements with polyamide support bre, optimised for water-glycol (only for BN/HC material)
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
0660 D 005 ON /-V
Size
0330, 0660
Type
D
Filtration rating in µm
ON: : 001, 003, 005, 010, 015, 020 BN4HC /-SS-SO361 : 003, 010
BN4AM : 003, 010 ECON2 : 003, 005, 010, 020
W/HC : 025, 050, 100, 200
Filter material
ON, BN4HC, ECON2, BN4AM, W/HC
Supplementary details
SS-SO361 stainl. steel core and end caps, polyamide support bre, optimised for water-glycol
V, N, NLT, HNBR, EPDM, K (for descriptions, see Point 2.1)
2.2 REPLACEMENT ELEMENT
VD 2 D . X /-V-L24
Type
VD differential pressure indicator
Pressure setting
2 standard 2 bar, others on request
Type of clogging indicator
(see Point 2.1)
Modication number
X the latest version is always supplied
Supplementary details
L..., LED, V, W (for descriptions, see Point 2.1)
2.3 REPLACEMENT CLOGGING INDICATOR