TECHNICAL CHARACTERISTICS
1)
Operating pressure max. 350 bar max. 5,000 psi
Flow rate max. 30 l/min max. 7.9 gpm
Switching pressure dierence 10% ± 3%
Dierence of switch-o pressure minus switch-on pressure
(max. setting pressure equals 100%)
20% ± 3%
30% ± 3%
Leakage
max. 30 cm³/min. at 350 bar and ν = 32 mm
2
/s | Port 1 → 2, port 3 → 2
Operating uid Hydraulic oil to DIN 51524 Part 1, 2 and 3
Ambient temperature range NBR: min. -30 °C up to max. +100 °C
FKM: min. -20 °C up to max. +120 °C
Temperature range of operating uid NBR: min. -30 °C up to max. +100 °C
FKM: min. -20 °C up to max. +120 °C
Viscosity range min. 10 mm²/s up to max. 420 mm²/s
Filtration Permitted contamination level of the operating uid as dened by ISO 4406
p ≤ 210 bar: min. class 21/19/16
p > 210 bar: min. class 19/17/14
MTTF
D
150 - 1200 years, assessment according to DIN EN ISO 13849-1:2016, Table C.1,
conrmation of ISO 13849-2:2013, Tables C.1 and C.2
Installation User-denable
Materials Valve body: Steel
Seals: NBR (standard)
FKM
Support rings: PTFE
Cavity 12121 metric
weight 0.26 kg
1
See “Conditions and Instructions for Valves” in brochure 53.000
APPLICATION EXAMPLE
Accumulator charging valve
The accumulator charging cycle is determined by the ratio between the pump volume, accumulator unloading volume and accumulator
size. The entire cycle time for charging and discharging the accumulator should be at least 1 second.
The drop-o load of the check valve inuences the accumulator charge pressure. We therefore recommend using a size 12 check
valve.
RV
A
2
3
1
M
T
P