425
E 7.580.1/03.12
Inline Filter MPSSF
up to 130 l/min, up to 450 bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head and a screw-on lter bowl.
Standard equipment:
without bypass valve
connection for a clogging indicator
oil drain plug in lter bowl
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941
ISO 2942
ISO 2943
ISO 3724
ISO 3968
ISO 11170
ISO 16889
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Betamicron
®
(BN4HC)
/-SS-SO361: 20 bar
Betamicron
®
(BH4HC): 210 bar
Betamicron
®
(BH4HC)
/-SS-SO361: 210 bar
Stainless steel wire mesh (D): 210 bar
Wire mesh (W/HC): 20 bar
Chemicron
®
(M): 210 bar
1.4 SEALS
FPM (Viton)
1.5 INSTALLATION
As inline lter or as manifold mounted
lter
1.6 SPECIAL MODELS AND
ACCESSORIES
Seals in NBR, NLT, EPDM, HNBR,
Kalrez
®
With bypass valve
Without port for clogging indicator
With gauge ports (for external piping of
pressure sensors)
Reverse ow check
Twin indicator version
Ex or IS differential indicators
Flanged versions available (SAE, RF,
RTJ, Destec
®
)
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.3 FILTER SPECIFICATIONS
MPSSF 30 MPSSF 110MPSSF 60 MPSSF 160 MPSSF 240 MPSSF 330
E 7.580.1/03.12
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524
Lubrication oils DIN 51517, API,
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506
Biodegradable operating uids VDMA
24568 HETG, HEES, HEPG
Fire-resistant uids HFA, HFB, HFC
and HFD
Operating uids with high water
content (>50% water content) on
request
Symbol for hydraulic systems
A
B
Nominal pressure 450 bar
Test pressure 675 bar
Temperature range -20 °C to +100 °C
Material of lter head 316 S11 stainless steel
Material of lter bowl UNS 318.03 DUPLEX
Type of clogging indicator VD (Diff. pressure indicator up to
450 bar oper. pressure)
Pressure setting of clogging indicator 5 bar (others on request)
Bypass cracking pressure (optional) 6 bar (others on request)
426
E 7.580.1/03.12
MPSSF450 BH/HC 60 N2 005 B X / -V
Filter type
MPSSF450 450 bar
Filter material of element
BN/HC Betamicron
®
(BN4HC)
BN/HC (/-SS-SO361) Betamicron
®
(BN4HC) – stainl. steel core and end caps, polyamide support bre
BH/HC Betamicron
®
(BH4HC)
BH/HC (/-SS-SO361) Betamicron
®
(BH4HC) – stainl. steel core and end caps, polyamide support bre
M Chemicron
®
W/HC Wire mesh
D Stainless steel wire mesh
Size of lter
30, 60, 110, 160, 240, 330
Type and size of connection
Type Port
thread
Filter size
30 60 110 160 240 330
BO ¼" BSPP
NO ¼" NPT
B2 ½” BSPP
N2 ½" NPT
B3 ¾" BSPP
N3 ¾" NPT
B4 1" BSPP
N4 1" NPT
B5 1¼" BSPP
N5 1¼" NPT
B6 1½" BSPP
N6 1½" NPT
Filtration rating in µm
BN/HC, BH/HC : 003, 005, 010, 020
BN/HC, BH/HC (/-SS-SO361) : 003, 010
M : 001, 003, 005, 010, 020
W/HC : 025, 050, 100, 200
D : 025, 040, 060, 100, 150, 200, 250
Type of clogging indicator
W without port (no clogging indicator)
A stainless steel blanking plug in indicator port
B visual
C electrical
D visual and electrical
E ¼"-NPT gauge ports for external connection of pressure sensors – not for size 30
BM+C visual with manual reset + electrical (= 2 indicators) – not for size 30
Modication number
X the latest version is always supplied
Supplementary details
B. cracking pressure of bypass valve (e.g. B3 = 3 bar, B6 = 6 bar); no details = without bypass valve
EX electrical clogging indicator EX version (Eexd IIC T6; cable length 3 m standard)
EX/ENC electrical clogging indicator EX version (Eexd IIC T6; with IP66 junction box, M20x1.5 cable entry)
IS intrinsically safe electrical clogging indicator with cable length 3 m (standard)
IS/ENC intrinsically safe electrical clogging indicator with IP66 junction box (M20x1.5 cable entry)
IS/2GBC intrinsically safe electrical clogging indicator with gold contacts (e. g. suitable for PLC)
L... light with appropriate voltage (24, 48, 110, 220 Volt)
LED 2 light emitting diodes up to 24 Volt
RC with reverse ow check (not for size 30)
RCRFB reverse ow check and reverse ow bypass
TB6 with triple bypass for reversible ow (= 1 check valve, 2 bypass valves - not for size 30)
N NBR seals
V FPM seals
NLT nitrile low temperature seals
HNBR hydrogenated nitrile (high temperature) seals
EPDM EPDM seals
K Kalrez
®
seals
W suitable for HFA and HFC emulsions, optimized for water glycols
Example for MPSSF450 in manifold version (plate mount): MPSSF450 BH/HC 60 P N2 005 B X / -V
Sizes
60P, 160P, 240P
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
For other clogging indicators
see brochure no. 7.050../..
only for clogging indicators
Type "D"
427
E 7.580.1/03.12
060-DH-100-D-V
Size
030, 060, 110, 160, 240, 330
Type
DH
Filtration rating in µm
Chemicron
®
(M) : 001, 003, 005, 010, 020
St. st. wire mesh (D) : 025, 040, 060, 100, 150, 200, 250
Filter material
M, D
Supplementary details
N, V, NLT, HNBR, EPDM, K (for descriptions, see Point 2.1)
2.3 REPLACEMENT ELEMENT - PROCESS TECHNOLOGY
VD 5 D . X /-V-L24
Type
VD differential pressure indicator
Pressure setting
5 standard 5 bar, others on request
Type
(see Point 2.1)
Modication number
X the latest version is always supplied
Supplementary details
L..., LED, V, W (for descriptions, see Point 2.1)
2.4 REPLACEMENT CLOGGING INDICATOR
2.2 REPLACEMENT ELEMENT
0060 D 003 BN4HC /-V-SS-SO361
Size
0030, 0060, 0110, 0160, 0240, 0330
Type
D
Filtration rating in µm
BN4HC, BH4HC : 003, 005, 010, 020
(Note: For /-SS-SO361
only 003 and 010 µm)
W/HC : 025, 050, 100, 200
Filter material
BN4HC, BH4HC, W/HC
Supplementary details
SS-SO361 stainl. steel core and end caps, polyamide support bre
N, V, NLT, HNBR, EPDM, K (for descriptions, see Point 2.1)
428
E 7.580.1/03.12
3.1 p-Q HOUSING CURVES BASED
ON ISO 3968
The housing curves apply to mineral oil
with a density of 0.86 kg/dm³ and
a kinematic viscosity of 30mm²/s.
In this case, the differential pressure
changes proportionally to the density.
p [bar]
Q [l/min]
Size 30: ½" BSPP/NPT
0
0.2
0.4
0.6
0.8
1
1.2
1.4
0 5 10 15 20 25 30
p [bar]
Q [l/min]
Size 60-110: ¾" BSPP/NPT
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
0.5
0 10 20 30 40 50
p [bar]
Q [l/min]
Size 60-110: ½" BSPP/NPT
0
0.1
0.2
0.3
0.4
0.5
0.6
0 5 10 15 20 25 30 35 40
p [bar]
Q [l/min]
Size 60-240: 1" BSPP/NPT
0
0.1
0.2
0.3
0.4
0.5
0.6
0 20 40 60 80 100
p [bar]
Q [l/min]
Size 30: ¼" BSPP/NPT
0
0.5
1
1.5
2
2.5
3
0 2 4 6 8 10 12 14 16
p [bar]p [bar]
p [bar]
3.2 GRADIENT COEFFICIENTS (SK) FOR FILTER ELEMENTS
The gradient coefcients in mbar/(l/min) apply to mineral oils with a kinematic
viscosity of 30 mm²/s. The pressure drop changes proportionally to the change in
viscosity.
BH4HC W/HC
3 µm 10 µm
30 91.2 36.3
60 58.6 18.1 0.757
110 25.4 8.9 0.413
160 16.8 5.9 0.283
240 10.6 3.9 0.189
330 7.7 2.8 0.138
p [bar]
Q [l/min] Q [l/min]
BN4HC: 60 BN4HC: 240
p [bar]
Q [l/min] Q [l/min]
BN4HC: 110 BN4HC: 330
p [bar]
Q [l/min] Q [l/min]
BN4HC: 30 BN4HC: 160
3. FILTER CALCULATION /
SIZING
The total pressure drop of a lter at a
certain ow rate Q is the sum of the
housing p and the element p and is
calculated as follows:
p
total
=∆p
housing
+∆p
element
p
housing
= (see Point 3.1)
p
element
= Q
SK*
viscosity
1000 30
(*see Point 3.2)
For ease of calculation, our Filter
Sizing Program is available on request
free of charge.
NEW: Sizing online at www.hydac.com
Other curves on request
429
E 7.580.1/03.12
4. DIMENSIONS
Inline Filter MPSSF450
Size 30
inlet
outlet
4 holes: M8x1.25 (12 deep)
1/4" NPT M8x1.25 in 50 PCD
oil drain
50
outlet
inlet
MPSSF A1 A2 b1 B2 ±5mm L LK
30 204 63.5 52 37 75 60
30 (1/4" NPT) 196 63.5 44 34 66 50
port for
clogging indicator
LK
430
E 7.580.1/03.12
Inline Filter MPSSF450
Size 60 - 330
4 holes:
Size 60-110: M10 x 1.5 (16 deep)
Size 160-330: M12 x 1.75 (24 deep)
oil drain
85
outlet
inlet
inlet
outlet
MPSSF A1 A2 b1 B2 ±5mm C L W
60 208 72 51 35 50 100 93
110 277 72 51 35 50 100 93
160 264 104 66 38 65 127 116
240 322 104 66 36 60 127 116
330 333 120 75 45 65 127 120
port for
clogging indicator
431
E 7.580.1/03.12
Inline lter, manifold-mounted MPSSF450...P (plate mount)
Size 60P, 160P, 240P
Type A1 A2 W L PCD mounting holes Weight incl. element [kg]
60P 201 72 88 100 76.2 7.50
160P 204 104 100 145 124.5 13.35
240P 261 104 100 145 124.5 18.93
outlet
4 holes: M12
vent hole
oil drain
inlet
port for
clogging indicator
432
E 7.580.1/03.12
NOTE
The information in this brochure relates to the operating conditions and applications
described.
For applications or operating conditions not described, please contact the relevant
technical department.
Subject to technical modications.
HYDAC FILTERTECHNIK GMBH
Industriegebiet
D-66280 Sulzbach/Saar
Tel.: 0 68 97 / 509-01
Fax: 0 68 97 / 509-300
Internet: www.hydac.com
E-Mail: lter@hydac.com
NOTES