241
E 7.574.0/02.08
Inline Filter LPF…D A
Manifold Mounted,
Rear Flanged
up to 160 l/min, up to 25 bar
1. TECHNICAL SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head and a screw-in lter bowl.
Standard equipment:
with bypass valve z
connection for a clogging indicator z
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941 z
ISO 2942 z
ISO 2943 z
ISO 3724 z
ISO 3968 z
ISO 11170 z
ISO 16889 z
Contamination retention capacities in g
Betamicron
®
(BN4HC)
LPF...D A 3 µm 5 µm 10 µm 20 µm
160 19.8 22.2 23.5 24.3
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Wire mesh (W/HC): 20 bar
1.4 SEALS
NBR (= Perbunan)
1.5 MOUNTING
As inline lter
1.6 SPECIAL MODELS AND
ACCESSORIES
without bypass valve z
without port for clogging indicator z
with bowl locking clip z
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.3 FILTER SPECIFICATIONS
Nominal pressure 25 bar
Fatigue strength at nominal pressure 10
6
load cycles
from 0 to nominal pressure
Temperature range -30 °C to +100 °C
Material of lter head aluminium
Material of lter bowl aluminium
Type of clogging indicator VM (differential pressure indicator up to
210 bar operating pressure)
Pressure setting of clogging indicator 5 bar (others on request)
Cracking pressure of bypass valve 3.5 bar (others on request)
Symbol for hydraulic systems
LPF
D A
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524 z
Lubrication oils DIN 51517, API, z
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506 z
Biodegradable operating uids VDMA z
24568 HETG, HEES, HEPG
Non-am operating uids HFA, HFB, z
HFC and HFD
Operating uids with high water z
content (>50% water content) on
request
E 7.574.0/02.08
242
E 7.574.0/02.08
LPF BN/HC 160 D A 10 D 1 . X /-L24
Filter type
LPF
Filter material of element
BN/HC Betamicron
®
(BN4HC)
W/HC Stainless steel wire mesh
Size of lter or element
LPF..DA: 160 (Sizes 240 and 280 on request!)
Operating pressure
D = 25 bar
Type and size of port
A 2 mounting bores
Filtration rating in µm
BN4HC : 3, 5, 10, 20
W/HC : 25, 50, 100, 200
Type of clogging indicator
W without port for clogging indicator
Y plastic blanking plug in indicator port
A with steel blanking plug in indicator port
B visual indicator
for other clogging indicators,
C electrical indicator
see brochure no. E 7.050.../...
D visual and electrical indicator
Type code
1
Modication number
X the latest version is always supplied
Supplementary details
B. cracking pressure of bypass valve (e. g.: B3.5 = 3.5 bar); no details = without bypass valve
GS bowl locking clip
L... light with appropriate voltage (24, 48, 110, 220 Volt) only for clogging indicators
LED 2 light emitting diodes up to 24 Volt type "D"
V FPM seals
W suitable for HFA and HFC emulsions
2. MODEL CODE (also order example)
2.1 COMPLETE FILTER
0160 D 010 BN4HC /-V
Size
0160
Type
D
Filtration rating in µm
BN4HC : 003, 005, 010, 020
W/HC : 025, 050, 100, 200
Filter material
BN4HC, W/HC
Supplementary details
V (for descriptions, see point 2.1)
2.2 REPLACEMENT ELEMENT
2.3 REPLACEMENT CLOGGING INDICATOR VM 5 D . X /-L24
Type
VM differential pressure indicator up to 210 bar operating pressure
Pressure setting
5 standard 5 bar, others on request
Type of clogging indicator
D (see point 2.1 )
Modication number
X the latest version is always supplied
Supplementary details
L..., LED, V, W (for descriptions, see point 2.1)
243
E 7.574.0/02.08
3. FILTER CALCULATION /
SIZING
The total pressure drop of a lter at a
certain ow rate Q is the sum of the
housing p and element p and is
calculated as follows:
p
total
= p
housing
+ p
element
p
housing
= (see point 3.1)
p
Element
= Q SK* • viscosity
1000 30
(*see point 3.2)
For ease of calculation, our Filter
Sizing Program is available on request
free of charge.
NEW: Sizing online at www.hydac.com
3.1 P-Q HOUSING GRAPHS BASED
ON ISO 3968
The housing graphs apply to mineral
oil with a density of 0.86 kg/dm
3
and
a kinematic viscosity of 30 mm
2
/s. In
this case, the differential pressure
changes proportionally to the density.
3.2 GRADIENT COEFFICIENTS (SK) FOR FILTER ELEMENTS
The gradient coefcients in mbar/(l/min) apply to mineral oils with a kinematic
viscosity of 30 mm
2
/s. The pressure drop changes proportionally to the change
in viscosity.
LPF 160
LPF... BN4HC W/HC
3 µm 5 µm 10 µm 20 µm
160 13.1 8.8 4.6 3.5 0.28
p [bar]
Q [l/min]
p [bar]
BN4HC: LPF 160
Q [l/min]
244
E 7.574.0/02.08
4. DIMENSIONS
LPF 160...D A (SHOWN WITH BOWL LOCKING CLIP)
NOTE
The information in this brochure relates to the operating
conditions and applications described.
For applications or operating conditions not described,
please contact the relevant technical department.
Subject to technical modications.
Filtertechnik GmbH
Industriegebiet
D-66280 Sulzbach/Saar
Tel.: 0 68 97 / 509-01
Fax: 0 68 97 / 509-300
Internet: www.hydac.com
E-Mail: lter@hydac.com
LPF... Weight incl. Volume of
D A element [kg] pressure
chamber [l]
160 2.30 0.60
O-ring
75 distance
required for
element
removal
Sizes 240 and 280 on request!