241
E 7.574.0/02.08
Inline Filter LPF…D A
Manifold Mounted,
Rear Flanged
up to 160 l/min, up to 25 bar
1. TECHNICAL SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
head and a screw-in lter bowl.
Standard equipment:
with bypass valve z
connection for a clogging indicator z
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941 z
ISO 2942 z
ISO 2943 z
ISO 3724 z
ISO 3968 z
ISO 11170 z
ISO 16889 z
Contamination retention capacities in g
Betamicron
®
(BN4HC)
LPF...D A 3 µm 5 µm 10 µm 20 µm
160 19.8 22.2 23.5 24.3
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Wire mesh (W/HC): 20 bar
1.4 SEALS
NBR (= Perbunan)
1.5 MOUNTING
As inline lter
1.6 SPECIAL MODELS AND
ACCESSORIES
without bypass valve z
without port for clogging indicator z
with bowl locking clip z
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.3 FILTER SPECIFICATIONS
Nominal pressure 25 bar
Fatigue strength at nominal pressure 10
6
load cycles
from 0 to nominal pressure
Temperature range -30 °C to +100 °C
Material of lter head aluminium
Material of lter bowl aluminium
Type of clogging indicator VM (differential pressure indicator up to
210 bar operating pressure)
Pressure setting of clogging indicator 5 bar (others on request)
Cracking pressure of bypass valve 3.5 bar (others on request)
Symbol for hydraulic systems
LPF
D A
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524 z
Lubrication oils DIN 51517, API, z
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506 z
Biodegradable operating uids VDMA z
24568 HETG, HEES, HEPG
Non-am operating uids HFA, HFB, z
HFC and HFD
Operating uids with high water z
content (>50% water content) on
request
E 7.574.0/02.08