137
E 7.567.0/02.08
Inline Filter LFM with
Differential Pressure Relief Valve
up to 120 l/min, up to 63 bar
1. TECHNICAL SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The filter housings are designed
in accordance with international
regulations. They consist of a filter
head with screw-in filter bowl.
Standard equipment:
With differential pressure controlled z
relief valve
Port for clogging indicator in filter z
head
1.2 FILTER ELEMENTS
HYDAC filter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941 z
ISO 2942 z
ISO 2943 z
ISO 3724 z
ISO 3968 z
ISO 11170 z
ISO 16889 z
Contamination retention capacities in g
Betamicron
®
BN4HC
LFM 3 µm 5 µm 10 µm 20 µm
60 6.5 7.3 7.8 8.0
110 13.8 15.5 16.4 16.9
140 18.1 20.3 21.5 22.2
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
1.4 SEALS
NBR (= Perbunan)
1.5 MOUNTING
As inline filter
1.6 SPECIAL MODELS AND
ACCESSORIES
Pressure release / oil drain plug z
(SO184)
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS TO ISO 2943
Hydraulic oils H to HLPD DIN 51524 z
Lubrication oils DIN 51517, API, z
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506 z
Biodegradable operating fluids z
VDMA 24568 HETG, HEES, HEPG
Non-flam operating fluids HFA, HFB, z
HFC and HFD
Operating fluids with high water z
content (>50% water content) on
request
1.10 IMPORTANT INFORMATION
Filter housing must be earthed z
When using electrical clogging z
indicators, the electrical power
supply to the system must be
switched off before removing the
clogging indicator connector.
1.3 FILTER SPECIFICATIONS
Nominal pressure 63 bar
Fatigue strength at nominal pressure 10
6
load cycles
from 0 to nominal pressure
Temperature range -30 °C to +100 °C
(LFM 140: -30 °C to -10 °C:
p
max
=31.5 bar)
Material of filter head aluminium
Material of filter bowl aluminium (steel on LFM 140)
Type of clogging indicator VM (differential pressure indicator
up to 210 bar operating pressure)
Pressure setting of clogging indicator 2 bar (others on request)
Cracking pressure of diff. pressure relief valve 3.5 bar (others on request)
Symbol for hydraulic systems
LFM 60 LFM 110 LFM 140
E 7.567.0/02.08