111
E 7.113.3/02.08
Change-Over
Filter NFD
up to10400 l/min, up to 25 bar
1. TECHNICAL
SPECIFICATIONS
1.1 FILTER HOUSING
Construction
The lter housings are designed
in accordance with international
regulations. They consist of a lter
housing and a threaded cover plate.
The housings are connected by a ball
change-over valve.
Standard equipment:
connection for a clogging indicator in z
lter head
1.2 FILTER ELEMENTS
HYDAC lter elements are validated
and their quality is constantly
monitored according to the following
standards:
ISO 2941 z
ISO 2942 z
ISO 2943 z
ISO 3724 z
ISO 3968 z
ISO 11170 z
ISO 16889 z
Contamination retention capacities in g
Betamicron
®
(BN4HC)
NFD Elements 3 µm 5 µm 10 µm 20 µm
per side
13XX 1x1300 R 181.0 200.7 241.4 273.1
26XX 1x2600 R 369.4 409.4 492.5 557.2
52XX 2x2600 R 738.8 818.8 985.0 1114.4
78XX 3x2600 R 1108.2 1228.2 1477.5 1671.6
104XX 4x2600 R 1477.6 1637.6 1970.0 2228.8
Filter elements are available with the
following pressure stability values:
Betamicron
®
(BN4HC): 20 bar
Wire mesh (W/HC): 20 bar
Stainless steel bre (V): 210 bar
Paper (P/HC) 10 bar
Betamicron
®
/Aquamicron
®
(BN4AM): 10 bar
Aquamicron
®
(AM) 10 bar
1.4 SEALS
NBR (= Perbunan)
1.5 MOUNTING
As tank-top return line lter or inline
lter.
1.6 SPECIAL MODELS AND
ACCESSORIES
On request
1.7 SPARE PARTS
See Original Spare Parts List
1.8 CERTIFICATES AND APPROVALS
On request
1.9 COMPATIBILITY WITH
HYDRAULIC FLUIDS ISO 2943
Hydraulic oils H to HLPD DIN 51524 z
Lubrication oils DIN 51517, API, z
ACEA, DIN 51515, ISO 6743
Compressor oils DIN 51506 z
Biodegradable operating uids VDMA z
24568 HETG, HEES, HEPG
Non-am operating uids HFA, HFB, z
HFC and HFD
Operating uids with high water z
content (>50% water content) on
request
1.10 IMPORTANT INFORMATION
Filter housing must be earthed z
When using visual clogging indicators, z
the BM version (visual with manual
reset) only should be used.
When using electrical clogging z
indicators, the electrical power supply
to the system must be switched off
before removing the clogging indicator
connector.
1.3 FILTER SPECIFICATIONS
Nominal pressure 25 bar
Temperature range -10 °C to +100 °C
Material of lter housing and cover plate Aluminium
Material of tube (housing) Steel
Material of ball change-over valve EN-GJS-400-15
Type of clogging indicator VM (differential pressure indicator)
VR (return line indicator)
Setting pressure of clogging indicator 2 bar (others on request)
Bypass cracking pressure 3 bar (others on request)
Symbol for hydraulic systems
Inline lter (2.X)
Tank-top return line lter (1.X)
E 7.113.3/02.08
NFD 1310 NFD 2610 NFD 5210 NFD 7810 NFD 10410
NFD 1310 NFD 2610 NFD 5210
Inline lter (2.X)
NFD 1340 NFD 2640 NFD 5240 NFD 7840 NFD 10440
112
E 7.113.3/02.08
2600 R 010 BN4HC /-V
Size
1300, 2600
Type
Filtration rating in µm
BN4HC, ECON2, V: 003, 005, 010, 020 P/HC: 010, 020 AM: 040
W/HC: 025, 050, 100, 200 BN4AM: 003, 010
Filter material
BN4HC, ECON2, V, W/HC, P/HC, BN4AM, AM
Supplementary details
V (for descriptions, see point 2.1)
2.2 REPLACEMENT ELEMENT
2.3 REPLACEMENT CLOGGING INDICATOR VM 2 D . X /-L24
Type
VM differential pressure indicator up to
210 bar operating pressure (only for inline lter code 2)
VR return line indicator up to
25 bar operating pressure (only for tank-top lter code 1)
Pressure setting
2 standard 2 bar, others on request
Type of clogging indicator (see point 2.1 )
Modication number
X the latest version is always supplied
Supplementary details
L..., LED, V (for descriptions, see point 2.1)
2. MODEL CODE (also order example)
2.1. COMPLETE FILTER
Filter type
NFD
Filter material of element
BN/HC Betamicron
®
(BN4HC) P/HC Paper
ECO/N ECOmicron
®
(ECON2) BN/AM Betamicron
®
/Aquamicron
®
W/HC stainless steel wire mesh AM Aquamicron
®
V stainless steel bre
Size of lter or element
NFD: 1310, 1340, 2610, 2640, 5210, 5240, 7810, 7840, 10410, 10440
Operating pressure
D = 25 bar
Type of change over
A = ball
Type and size of port
NFD BN/HC 2610 D A P 10 D 1 . X /-L24
Filtration rating in µm
BN4HC, ECO/N, V: 3, 5, 10, 20 P/HC: 10, 20 AM: 40
W/HC: 25, 50, 100, 200 BN/AM: 3, 10
Type of clogging indicator
Y with plastic blanking plug in indicator port
A with steel blanking plug in indicator port
B visual indicator (version 1.X only)
BM visual indicator
C electrical indicator
D visual and electrical indicator
Type code
1 Tank-top return line lter - return line indicator (VR...)
- inlet ange horizontal at top, outlet vertical (from size NFD 5210 horizontal)
- tank seal supplied
2 Inline lter - differential pressure indicator (VM...)
- inlet ange horizontal at bottom, outlet vertical (from size NFD 5210 horizontal)
Modication number
X the latest version is always supplied
Supplementary details
B. special cracking pressure of bypass valve (e. g.: B6 = 6 bar)
EM manual vent with shut-off valve
EP permanent vent via Minimess hose
KB no bypass valve
L... light with appropriate voltage (24, 48, 110, 220 Volt)
LED 2 light emitting diodes up to 24 Volt
SB4 lling line with Ø4 mm orice
V FPM seals
VKD drain tted with ball shut-off valve
39 connection alternative (see point 2.4)
for other clogging indicators,
see brochure no. 7.050.../...
only for clogging indicators
type D
Further types and sizes of
port on request!
For examples, see point 3.3
= discontinued model
x = on request
= standard model
= discontinued model
Type Port Filter size
1310 1340 2610 2640 5210 5240 7810 7840 10410 10440
P SAE DN 100
z z z z z
Code Filter size
1310 1340 2610 2640 5210 5240 7810 7840 10410 10440
1 x x x
2
z z z z z
113
E 7.113.3/02.08
2.4 CONNECTION ALTERNATIVES
(Example)
Supplementary details .. / – 0 3
1st digit = position of inlet valve
2nd digit = position of the outlet valve
Standard model
Not given as a supplementary detail in the model code
Not available!
stand.
line of vision
Line of vision
Type code .. / –39
NFD 2610/2640 .. A 2.0 / –XX
(possible supplementary detail)
NFD 5210/5240 .. A 2.0 / –XX
(possible supplementary detail)
stand.
stand.
IN
OUT
1) corresponds to type 03
2) corresponds to type 39
3) corresponds to type 33
IN
OUT
IN
OUT
114
E 7.113.3/02.08
3. FILTER CALCULATION /
SIZING
The total pressure drop of a lter at a
certain ow rate Q is the sum of the
housing p and element p and is
calculated as follows:
p
total
= p
housing
+ p
element
p
housing
= use graphs (see point 3.1)
p
element
= Q SK* • viscosity
1000 30
(*see point 3.2)
n = no. of elements (see
point 1.2 lter elements)
For ease of calculation, our Filter
Sizing Program is available on request
free of charge.
NEW: Sizing online at www.hydac.com
3.1 P-Q HOUSING GRAPHS BASED
ON ISO 3968
The housing graphs apply to mineral
oil with a density of 0.86 kg/dm
3
and
a kinematic viscosity of 30 mm
2
/s. In
this case, the differential pressure
changes proportionally to the density.
3.2 GRADIENT COEFFICIENTS (SK) FOR FILTER ELEMENTS
The gradient coefcients in mbar/(l/min) apply to mineral oils with a kinematic
viscosity of 30 mm
2
/s. The pressure drop changes proportionally to the change in
viscosity.
p [bar]
Q [l/min]
BN4HC: 1300 R...
p [bar]
Q [l/min]
BN4HC: 2600 R...
NFD V W/HC ECON2
3 µm 5 µm 10 µm 20 µm 3 µm 5 µm 10 µm 20 µm
1300 0.5 0.4 0.3 0.2 0.045 0.8 0.6 0.4 0.3
2600 0.3 0.2 0.1 0.1 0.018 0.4 0.3 0.2 0.1
NFD 1310/2610 ... 1.X
NFD 1310/1340 / 2610/2640 ... 2.X
NFD 5210 ... 1.X/2.X / 5240 ... 2.X
NFD 7810/7840 ... 2.X
Q [l/min]
p [bar]
NFD 10410/10440 ... 2.X
p [bar]p [bar]p [bar] p [bar]
Q [l/min]
Q [l/min]
Q [l/min]
Q [l/min]
3.3. OTHER CONNECTION SIZES AND TYPES ON REQUEST!
Examples:
115
E 7.113.3/02.08
4. DIMENSIONS
NFD 1310/2610...2.X
connection
for clogging
indicator
lling connection
G 3/4
NFD 1310/2610...1.X
On request
lling
connection
NFD No. of Weight incl. Volume of
elements element [kg] pressure
per side chamber [l]
1310...1.X 1x 1300 R... 83.7 28.2
2610...1.X 1x 2600 R... 101.0 50.8
1310...2.X 1x 1300 R... 122.7 35.8
1340...2.X
2610...2.X 1x 2600 R... 140.0 58.1
2640...2.X
connection for
clogging indicator
connection for
clogging indicator
clogging indicator
VM
drain
contaminated side G 1/2
vent
G 1/2
NFD 1340/2640...2.X
Standard series
vent
G 1/2"
lling
connection
G 3/4"
connection for
differential
pressure
indicator
lling
connection
G 3/4"
connection for
differential
pressure
indicator
size
size
drain on
contaminated
side G 1/2"
drain on
contaminated
side G 1/2"
INLET
OUTLET
116
E 7.113.3/02.08
NFD 5210...2.X
NFD 5210...1.X
On request
NFD 52XX...2.X /-1+2
vent
G 1/2
connection for
clogging indicator
vent G 1/2
drain G 1/2
connection for
clogging indicator
vent G 1/2
drain G 1/2
NFD No. of Weight incl. Volume of
elements element [kg] pressure
per side chamber
[l]
5210...1.X 2x 2600 R... 258.0 124.0
5210...2.X 2x 2600 R... 276.8 126.4
5240...2.X
5210../-1+2...2.X 1x 2600 R... and 217.4 94.3
2x 2600 R...
NFD 5240...2.X
Standard series
vent
G 1/2"
lling
connection
G 3/4"
connection
for differential
clogging
indicator
connection
for differential
clogging indicator
drain on cont-
aminated
sideG 1/2"
INLET
OUTLET
117
E 7.113.3/02.08
NFD 78XX...2.X /-3+1
NFD 7810...2.X
connection for
clogging indicator
vent G 1/2
drain G 1/2
drain G 1/2
vent G 1/2
NFD No. of Weight incl. Vol. of
elements element [kg] pressure
per side chamber [l]
7810 3x 2600 R... 391.6 182.8
7840
7810../-3+1 3x 2600 R... and 286.6 122.2
1x 2600 R...
NFD 7840...2.X
Standard series
vent
G 1/2"
lling
connection
G 3/4"
connection
for differential
clogging
indicator
connection
for differential
clogging
indicator
INLET
OUTLET
drain on
contaminated
side G 1/2"
118
E 7.113.3/02.08
NOTE
The information in this brochure relates to the operating
conditions and applications described.
For applications or operating conditions not described,
please contact the relevant technical department.
Subject to technical modications.
Filtertechnik GmbH
Industriegebiet
D-66280 Sulzbach/Saar
Tel.: 0 68 97 / 509-01
Fax: 0 68 97 / 509-300
Internet: www.hydac.com
E-Mail: lter@hydac.com
NFD 104XX...2.X /-1+4
NFD 10410...2.X
NFD No. of Weight incl. Volume of
elements element [kg] pressure
per side chamber [l]
10410 4x 2600 R... 510.4 251.0
10440
10410../-1+4 1x 2600 R... and 328.3 154.0
4x 2600 R...
connection for
clogging indicator
vent G 1/2
vent G 1/2
drain G 1/2
drain G 1/2
NFD 10440...2.X
Standard series
vent
G 1/2"
lling
connection
G 3/4"
connection
for differential
clogging
indicator
connection
for differential
clogging indicator
INLET