E 7.050.15/11.16
VR 2 D . X /-V-L24
Type
VMF return line indicator; connection G
1
/
8
VR return line indicator; connection G
1
/
2
VRD return line indicator; for differential pressure cavity
VM differential pressure indicator; up to 210 bar operating pressure
VD differential pressure indicator; up to 420 bar operating pressure
VL differential pressure indicator; up to 25 bar operating pressure
V02 differential pressure indicator; piped separately; up to 100 bar operating pressure
Pressure setting
see particular clogging indicator
Version
B visual with automatic reset (for vertical installation only!)
BF visual, mobile
BM visual with manual reset
C electrical
CA electrical with AMP connector (Mark II)
CD electrical with Deutsch connector (DT 04-2P)
CJ electrical with AMP Junior Power Timer connector
CM electrical with M12x1 connector
CS electrical with AMP Superseal connector
D visual/electrical
E pressure gauge, horizontal
ES pressure gauge, vertical
F pressure switch
FD pressure switch with Deutsch connector (DT 04-2P)
FJ pressure switch with AMP Junior Power Timer connector
FS pressure switch with AMP Superseal connector
GC electronic
GW electronic
K pressure gauge, horizontal
LE visual/mechanical with 100% switching contact
LEM visual/mechanical with 100% switching contact and M12x1 connector
LZ visual/mechanical with 75% and 100% switching contact
M electrical, earth-switching
R pressure gauge, horizontal
RS pressure gauge, vertical
UBM visual, negative pressure
UE negative pressure gauge, horizontal
UF negative pressure switch
V visual/analogue
VE visual/analogue with 100% switching contact
VZ visual/analogue with 75% and 100% switching contact
Modication number
X the latest version is always supplied
Supplementary details
30C cold start suppression of switch outputs up to 30 °C ±5 °C
(only for C-, D-, LZ indicators; power supply only with direct current – max. 24 volts;
C and D indicators only for VD and VM; D and LZ indicators only as N/O contact)
L... lamp with appropriate voltage (24, 48, 110, 230 volts) only for
LED 2 light-emitting diodes up to 24 volts version "D"
OE N/C function
SO135 indicator suitable for PLC control via gold crosspoint contacts
W suitable for oil/water emulsions (HFA, HFC)
V seal made from Viton (FKM), suitable for phosphate ester uid (HFD-R) and biodegradable oils
(must be specied for version "GW")
Addition: For VMF indicators B, LE, LZ and C/-EX2G a "/-V" must be added for a Viton version.
For all other VMF versions, the standard is V and is not specied.
Supplementary details for "GC" type
113 N/O function pressure peak suppression up to 10 sec.
cold start suppression of switching outputs
(PNP technique, positive switching) up to 25 °C
123 N/C function pressure peak suppression up to 10 sec.
cold start suppression of switching outputs
(PNP technique positive switching) up to 25 °C
30C cold start suppression of switching outputs up to 30 °C (other temperatures on request)
LED 3 LEDs (green, yellow, red) in terminal box
PF oating switching outputs (due to relay in the plug)
SP analogue signal: voltage output 1-10 V
SQ analogue signal: voltage output 4 to 20 mA (current source)
Supplementary details to "GW" type
113 N/O function pressure peak suppression up to 10 sec.
cold start suppression of switching outputs
(PNP technique positive switching) up to 25 °C
123 N/C function pressure peak suppression up to 10 sec.
cold start suppression of switching outputs
(PNP technique positive switching) up to 25 °C
4. MODEL CODE
4.1 STANDARD CLOGGING INDICATORS
Must be specied!
Others on request
Must be specied!
Others on request
if SP or SQ are not specied
"current sink" model supplied