E 5.925.2/12.10
395
Pressure drop
Flow rate
Inline connection housings
Code Part No. Material Ports Pressure
FH082-SB3 560919 Steel, zinc-plated 3/8 BSP 350 bar
FH082-AB3 3011423 Aluminium, clear anodized 3/8 BSP 245 bar
other housings on request
FC08-2
Form tools
Tool Part No.
Rougher FC08-2 175473
Finisher FC08-2 175474
Measured at ν = 34 mm²/s
T
Oil
= 46 °C
Standard models
Model code Part No.
WK08W-01-C-N-24DG 3018585
WK08W-01-C-N-230AG 3044038
other models on request
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str.
D-66280 Sulzbach/Saar
Tel: 0 68 97 /509-01
Fax: 0 68 97 /509-598
E-Mail: utec@hydac.com
The information in this brochure
relates to the operating conditions
and applications described.
For applications or operating
conditions not described, please
contact the relevant technical
department.
Subject to technical modications.
millimeter (inch)
technical modications reserved
torque 4
+2
Nm
After loosening moun-
ting nut, coil
can be rotated
through 360° and
removed.
7/8 hex
torque 25
+5
Nm
torque 4
+2
Nm
thick
max. without M.O.
NOTE
millimeter (inch)
technical modications reserved
Manual override
After removing
mounting nut,
manual operation is
possible by twisting
button
counterclockwise
termination
WK08W-01 M - C - N - 24 DG
Designation
Directional poppet valve UNF
Cavity 08
Function code W
Type 01 = standard
Option
Omission = No Option
M = Manual Override
Body and Ports
C = Cartridge Only
SB3 = 3/8 BSP ports, steel body
AB3 = 3/8 BSP ports, aluminium body
Seals
N = NBR
V = FKM
Coil Voltage
DC
12 = 12 V DC
24 = 24 V DC
AC (internally full wave rectied)
115 = 115 V AC
230 = 230 V AC
other voltages on request
Coil Connector
DC: DG = DIN Connector to EN 175301-803
DK = Kostal threaded connection M27x1
DL = Leadwires (2) - 457mm, (18") long
DN = Deutsch connector, 2 pole
DT = AMP Junior Timer, 2-pole, radial
AC: AG = DIN Connector to EN 175301-803
other connection types on request