2/2 slip-in cartridge cover
Function 1D
Series LD-CCE
Size16 up to 63
FEATURES:
- 2/2 slip-in cartridge covers with remote control port
according to ISO 7368
- with possibility to built-in a nozzle at port X
SPECIFICATIONS:
Operating pressure: max. 350 bar
Temp. range of operating fluid: min. -20°C up to max. +80°C
Ambient temperature range: min. -20°C up to max. +60°C
Operating fluid: hydraulic fluid according to DIN 51524
part 1 and 2
Filtration: Class 20/18/15
according to ISO 4406 (C)
Viscosity range: 2,8 up to 380 mm²/s
Seals: FKM + PU (NBR / FKM on request)
Directional FUNCTION:
By using a 1D-cover in combination with a 2/2 slip-in cartridge the port X will
be connected to tank at pressure discharge - so that a directional function is
realized with flow from A -> B or B -> A.
If the control port X of the cover will be charged with the highest system
pressure or with the highest pressure of A or B, the flow from A to B and
inverse is blocked.
Check FUNCTION:
By using a 1D-cover in combination with a 2/2 slip-in cartridge valve a check
function can also be realized, by connecting the control port X with port B.
Then the direction of the flow is blocked A ->B (B ->A).
The 2/2 slip-in cartridge cover 1D can be combined with the cones B and C.
SYMBOL
P max = 350 bar
E 5.235.0 /01.13
Nozzles
Ports NG16 NG25 NG32
X M5 M6 M6
NG40 NG50 NG63
X M8 M8 M10
Nozzle 0,8 Part No.
Nozzle covers M5x0,8 6071916
Nozzle covers M6x0,8 6071917
Nozzle covers M8x0,8 6071918
Nozzle covers M10x0,8 6071919
Nozzle 1,5 Part No.
Nozzle covers M5x1,5 6071920
Nozzle covers M6x1,5 6071921
Nozzle covers M8x1,5 6071922
Nozzle covers M10x1,5 6071923
DIMENSIONS
Standard models
Type Part No.
LD-CCE 16 D 6 1D 6071627
LD-CCE 25 D 6 1D 6071628
LD-CCE 32 D 6 1D 6071658
LD-CCE 40 D 6 1D 6071659
LD-CCE 50 D 6 1D 6071660
LD-CCE 63 D 6 1D 6071671
LD -C C E 16 D 6 1D
Name
LD-CCE= 2/2 slip-in cartridge covers,
Standard
Nominal size
Size16, 25, 32, 40, 50, 63
Series
named by manufacturer
Type
Threads and control ports according to ISO 7368
Cover code
1D = functional symbol
MODEL CODE
Nozzle choice
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
Δp over nozzle
Nozzle diameter
Flow rate