HYDAC Fluidtechnik
Minivalves
E 51.400.1 /05.11
Content
1 2
1
2
1
2
1
2
5.147.0FC06-2U35020WS06Y-01
2/2-poppet valve
normally open
5.146.0FC06-2U35020WS06Z-01
2/2-poppet valve
normally closed
Directional poppet valves
5.145.0FC06-3U35020RV06C-01
5.144.0FC06-3U35015RV06B-01
Check valve with
integral relief
5.143.0FC06-2U35020RV06A-01
Check valve
Check valves
5.142.0FC06-2U35015SR06-01
2-way flow control
valve
Flow valves
5.141.0FC06-2U35020DB06C-01
5.140.0FC06-2U35015DB06A-01
Pressure relief valve
direct acting
Brochure no.cavity
p
max
(bar)
Q
max
(l/min)
Type
Symbol
Pressure valves
Z
Y
13
2
1
2
3
4
1
2
13
2 4
13
2 4
S1 S2
13
2 4
1
2
W
V
C
Y
E
G
H
J
24 VDC2610162
5.155.0
Coil with 2 leadwires
0,75mm², 450 mm long
12 VDC2610151Plug Type L
24 VDC2610150
5.155.0
Deutsch-Plug, axial
12 VDC2610149Plug Type N
230 VAC
2610159 +
2600582*
115 VAC
2610156 +
2600582*
*Plug with rectifier
205 VDC2610159
105 VDC2610156
24 VDC2610161
5.155.0
Plug to EN 175301-803
FORM B DIN 43650B
12 VDC2610160Plug Type G
Brochure
No.Electrical connectionCoil voltageType (Code No.)
Coils 32-1329 for
Minivalves
5.154.0FC06-4U35011WK06J-014/3-spool valve
S1 S2
5.153.0FC06-4U3509WK06H-014/3-spool valve
S1 S2
5.152.0FC06-4U3507WK06G-014/3-spool valve
S1 S2
5.151.0FC06-4U35011WK06E-014/3-spool valve
5.150.0FC06-4U35010WK06Y-014/2-spool valve
5.149.0FC06-3U35010WK06C-013/2-spool valve
5.156.0FC06-2U35015WK06V-01
2/2-Spool valve,
normally open
5.148.0FC06-2U35010WK06W-01
2/2-Spool valve,
normally closed
Brochure no.cavity
p
max
(bar)
Q
max
(l/min)
Type
Symbol
Directional spool
valves
Pressure Relief Valve
Ball type, direct acting
Cartridge-Minivalve – 350 bar
DB06A-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extend service life
- Quick response
- Adjustable under full system pressure
- Adjustable across the entire pressure range
- Various pressure ranges up to 350 bar
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 15 l/min
Pressure ranges: 0 up to 125 bar
0 up to 210 bar
0 up to 350 bar
Leakage: leakage-free, < max. 0,35 cm³/min at 75%
nominal pressure
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Ball: hardened steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-2
Weight: 0,068 kg
FUNCTION
The Pressure relief valve DB06A is a
direct acting, spring loaded ball valve. Its
job is to limit the pressure in the system.
The spring acts with a certain force on the
ball and presses it on the valve seat. On
the opposite side the system pressure
works at port 1. If the hydraulic force is
lower than the spring pressure the valve
remains closed. Only if the force is higher,
the valve opens and the flow will be let to
port 2 (tank). If the system pressure is
equal to the spring pressure the valve
closes again.
Attention: Pressure at port 2 increases the
opening pressure! If ports are
interchanged and the pressure adjustment
is higher than the operating pressure, the
function of the valve is invalid.
SYMBOL
up to 15 l/min
up to 350 bar
D 5.140.1 /05.11
UNF
MODEL CODE
DB06A – 01 – C – N – 300 V 100
Basic model
Pressure relief valve, direct acting
Type
01 = Standard
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Pressure range
180 = 0 up to 125 bar (1800PSI)
300 = 0 up to 210 bar (3000PSI)
500 = 0 up to 350 bar (5000PSI)
Adjustment option
V = adjustable by tool
Setting
omission = 50% of max. Pressure
100 = factory preset, pressure in PSI (/10)
Other pressures on request
DIMENSIONS
Standard models
Name Code No.
DB06A-01-C-N-330V 2610235
DB06A-01-C-N-500V 2610155
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
CAVITY
FC06-2
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
Pressure Relief Valve
Poppet type, direct acting
Cartridge-Minivalve – 350 bar
DB06C-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extend service life
- Fast reaction
- Adjustable under full system pressure
- Adjustable over the entire pressure range
- Various pressure ranges up to 350 bar
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 20 l/min
Pressure ranges: 0 up to 125 bar
0 up to 210 bar
35 up to 350 bar
Leakage: leakage-free, < max. 0,35 cm³/min at 75%
nominal pressure
Temperature range of operating fluid: Min. – 30°C up to max. +100°C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-2
Weight: 0,068 kg
FUNCTION
The Pressure relief valve DB06C is a
direct acting, spring loaded ball valve. Its
job is to limit the pressure in the system.
The spring acts with a certain force on the
piston and presses it on the valve seat.
On the opposite side the system pressure
works at port 1. I f the hydraulic force is
lower than the spring pressure the valve
remains closed. Only if the force is higher,
the valve opens and the flow will be let to
port 2 (tank). If the system pressure is
equal to the spring pressure the valve
closes again.
Attention: Pressure at port 2 increases the
opening pressure! If ports are
interchanged and the pressure adjustment
is higher than the operating pressure, the
function of the valve is invalid.
SYMBOL
up to 20 l/min
up to 350 bar
D 5.141.1 /05.11
UNF
MODEL CODE
DB06C – 01 – C – N – 400 V 300
Basic model
Pressure relief valve, direct acting
Type
01 = Standard
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Pressure range
180 = 0 up to 125 bar (1800PSI)
300 = 0 up to 210 bar (3000PSI)
500 = 35 up to 350 bar (5000PSI)
Adjustment option
V = adjustable by tool
Setting
omission = 50% of max. Pressure
300 = factory preset pressure in PSI (/10)
Other pressures on request
DIMENSIONS
Cavity
FC06-2
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
All dimensions in inch (mm)
Subject to technical modification
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
Standard models
Name Code No.
DB06C-01-C-N-180V 2610322
DB06C-01-C-N-300V 2610324
DB06C-01-C-N-500V 2610342
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
Flow Control Valve
Spool type, direct acting
Cartridge-Minivalve – 350 bar
SR06-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extend service life
- Superior stability throughout the entire flow range
SPECIFICATIONS
Operating pressure: max. 350 bar at port 1 (pump)
max. 210 bar at port 2 (consumer)
Nominal flow: max. 15 l/min
Flow ranges: 0,25 up to 1,00 l/min
1,00 up to 3,80 l/min
3,80 up to 15,0 l/min
Temperature range of operating fluid: Min. – 30°C up to max. +100°C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-2
Weight: 0,023 kg
FUNCTION
The SR06 is a 2 way directional flow
control-valve, which keeps the nominal
flow constant by means of a control
function. The nominal flow is almost
independent of the pressure and the
viscosity. The valve is equipped with fixed
orifice and integrated pressure
compensator. The measuring orifice
determines the nominal flow-adjustment
range which is adjustable within a small
range. If there is flow from port 1 to 2, a
pressure differential is created at the
measuring orifice. If the pressure
compensator is in regulating position
there is a balance of pressure differential
at control piston surface on the one side
and spring force on the other side. With
rising flow (higher pressure differential)
the cross-section of the regluating oricifice
will be controlled that there is a balance of
forces. Hereby a constant outlet flow will
be reached. In opposite direction there is
free unregulated flow.
SYMBOL
up to 15 l/min
up to 350 bar
1
2
D 5.142.1 /05.11
UNF
MODEL CODE
SR06 – 01 – C – N – 0.3 V 0.1
Basic model
flow control valve, direct acting
Type
01 = Standard
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Nominal flow range
0.3 = 0,25 up to 1,00 l/min (0,3 gpm)
1.0 = 1,00 up to 3,80 l/min
(1,0 gpm)
4.0 = 3,80 up to 15,0 l/min
(4,0 gpm)
Adjustment option
V = adjustable by tool
Setting
none = 50% of maximal Nominal flows
0.1 = 0,23 l/min – optional pre-adjustment on request
DIMENSIONS
Cavity
FC06-2
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
All dimensions in inch (mm)
Subject to technical
modifications
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
Standard models
Name Code No.
SR06-01-C-N-0.3V 2610213
SR06-01-C-N-1.0V 2610194
SR06-01-C-N-4.0V 2610214
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
Check Valve
Ball type
Cartridge-Minivalve – 350 bar
RV06A-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extend service life
- Superior stability throughout the entire flow range
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 20 l/min
Cracking pressures: 0,35 bar
2,10 bar
Leakage: leakage-free, < max. 0,35 cm³/min at
nominal pressure
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Ball: hardened steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +12C)
Support rings: PTFE
Cavity: FC06-2
Weight: 0,045 kg
FUNCTION
The check valve RV06A is a direct
acting, spring loaded ball valve.
If there is no flow the spring holds the
ball in closed position and blocks
therefore from port 2 to 1. The valve
opens, if the pressure at port 1 is
higher than the pressure at port 2
including the spring force.
SYMBOL
up to 20 l/min
up to 350 bar
1
2
D 5.143.1 /05.11
UNF
MODEL CODE
RV06A – 01 – C – N – 30
Basic model
Check valve
Type
01 = Standard
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Setting
5 = 0,35 bar (5 PSI)
30 = 2,10 bar (30 PSI)
DIMENSIONS
Cavity
FC06-2
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
Standard models
Name Code No.
RV06A-01-C-N-05 2610212
RV06A-01-C-N-30 2610154
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
Check Valve
Ball type
with pressure relief function
Cartridge-Minivalve – 350 bar
RV06B-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extend service life
- Combination of two functions in one valve
- Pressure ranges up to 350 bar
- adjustable under full pressure
- fast closing
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 15 l/min
Pressure ranges (DB): 0 up to 125 bar
0 up to 210 bar
0 up to 350 bar
Cracking pressure (Che ckfunction): 0,35 bar
Leakage: leakage-free, < max. 0,35 cm³/min at
75% nominal pressure
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Ball: hardened steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +12C)
Support rings: PTFE
Cavity: FC06-3
Weight: 0,027 kg
FUNCTION
The check valve RV06B is a direct acting,
spring loaded ball valve with integrated
pressure relief valve.
If there is no flow the spring holds the ball
in closed position and blocks therefore
flow from port 1 to 2. The check valve
opens, if the pressure at port 2 is higher
than the pressure at port 1 including the
spring force. If the pressures rises in the
inlet pipe over the pre-adjusted pressure
the relief valve opens to tank. Any
pressure at port 3 is additive to the relief
pressure setting.
SYMBOL
up to 15 l/min
up to 350 bar
1
3
D 5.144.1 /05.11
UNF
MODEL CODE
RV06B – 01 – C – N – 300 V 100
Basic model
Check valve, direct acting
Type
01 = Standard
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Pressure ranges
180 = 0 up to 125 bar (3000 PSI)
300 = 0 up to 210 bar (3000 PSI)
500 = 0 up to 350 bar (5000 PSI)
Adjustment option
V = adjustable by tool
Setting
none = 50% of max. Pressure
100 = 69 bar (1000 PSI) – factory preset pressure
DIMENSIONS
Cavity
FC06-3
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
Pressure relief
Check function
Standard models
Name Code No.
RV06B-01-C-N-300V 2610236
RV06B-01-C-N-500V 2610164
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH063-SS4 2600493 steel, zinc plated SAE-4 420 bar
FH063-AS4 2600493 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610186
Seal kit-FKM 2610187
Tools
Code Part No.
Rougher 2582050
Finisher 2582051
Check Valve
Ball type
with pressure relief function
Cartridge-Minivalve – 350 bar
RV06C-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extend service life
- Combination of two functions in one valve
- Pressure ranges up to 350 bar
- adjustable under full pressure
- fast closing
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 20 l/min
Pressure ranges (DB): 0 up to 125 bar
0 up to 210 bar
35 up to 350 bar
Cracking pressure (check function): 0,35 bar
Leakage: leakage-free, < max. 0,35 cm³/min at
75% nominal pressure
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-3
Weight: 0,027 kg
FUNCTION
The check valve RV06C is a direct
acting, spring loaded ball valve with
integrated pressure relief valve.
If there is no flow the spring holds the
ball in closed position and blocks
therefore flow from port 1 to 2. The
check valve opens, if the pressure at
port 2 is higher than the pressure at
port 1 including the spring force. If the
pressures rises in the inlet pipe over
the pre-adjusted pressure the relief
valve opens to tank. Any pressure at
port 3 is additive to the relief pressure
setting.
SYMBOL
up to 20 l/min
up to 350 bar
1
3
D 5.145.1 /05.11
UNF
MODEL CODE
RV06C – 01 – C – N – 180 V 100
Basic model
Check valve, direct acting
Type
01 = Standard
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Pressure range
180 = 0 up to 125 bar (1800 PSI)
300 = 0 up to 210 bar (3000 PSI)
500 = 35 up to 350 bar (5000 PSI)
Adjustment option
V = adjustable by tool
Setting
none = 50% of max. Pressure
100 = 69 bar (1000 PSI) – factory preset pressure
DIMENSIONS
Cavity
FC06-3
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
Pressure relief
Check function
Standard models
Name Code No.
RV06C-01-C-N-180V 2610323
RV06C-01-C-N-300V 2610325
RV06C-01-C-N-400V 2610343
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH063-SS4 2600493 steel, zinc plated SAE-4 420 bar
FH063-AS4 2600493 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610186
Seal kit-FKM 2610187
Tools
Code Part No.
Rougher 2582050
Finisher 2582051
2/2 Solenoid Directional Valve
Poppet type, pilot operated,
normally closed
Cartridge-Minivalve – 350 bar
WS06Z-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coil easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 20 l/min
Leakage: leakage-free, < max. 0,35 cm³/min at
nominal pressure
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-2
Weight: Complete valve: 0,165 kg
Coil only: 0,088 kg
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
Switching time: Energized: approx. 35 ms
De-energized: approx. 50 ms
FUNCTION
In de-energized mode the valve
blocks flow from port 2 to 1.
In the opposite direction the valve
piston opens at a pressure differential
from approx. 1,8 bar (Check function).
If energized, there is flow from port 2
to 1. A backflow from port 1 to 2 is
severely restricted.
SYMBOL
up to 20 l/min
up to 350 bar
D 5.146.1 /05.11
UNF
MODEL CODE
WS06Z – 01M – C – N – 24 DN
Basic model
Directional poppet valve, pilot operated
Type
01 = Standard
01M = manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
DIMENSIONS
Cavity
FC06-2
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
Standard models
Code Part No.
WS06Z-01-C-N-0 without coil 2610237
(coil please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
2/2 Solenoid Directional Valve
Poppet type, pilot operated,
normally open
Cartridge-Minivalve – 350 bar
WS06Y-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coil easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 20 l/min
Leakage: leakage-free, < max. 0,35 cm³/min at
nominal pressure
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-2
Weight: Complete valve: 0,165 kg
Coil only: 0,088 kg
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a
rectifier built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
Switching time: Energized: approx. 50 ms
De-energized: approx. 35 ms
FUNCTION
In de-energized mode there is flow
from port 2 to 1.
If energized, the valve blocks flow
from port 2 to 1.
In the opposite direction it opens if the
pressure force on den piston is higher
than the magnet force (approx. 9 up
to 20 bar).
SYMBOL
up to 20 l/min
up to 350 bar
D 5.147.1 /05.11
UNF
MODEL CODE
WS06Y – 01M – C – N – 24 DN
Basic model
directionalpoppet valve, pilot operated
Type
01 = Standard
01M = manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
DIMENSIONS
Cavity
FC06-2
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
Standard models
Code Part No.
WS06Y-01-C-N-0 without coil 2610209
(coil please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
Annotation
The technical information in this
brochure are relating to the operating
conditions and applications.
At deviant applications and/or
operating conditions please contact
the technical dept.
Technical information are
subject to technical modifications.
2/2 Solenoid Directional Valve
Spool type, direct acting,
Cartridge-Minivalve – 350 bar
WK06W-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coil easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 10 l/min
Leakage: < max. 90 cm³/min at 207 bar
and 28 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTFd: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-2
Weight: Complete valve: 0,165 kg
Coil only: 0,088 kg
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
FUNCTION
In de-energized mode the valve is
blocked in both directions.
If energized, the valve opens and
allows the flow in both directions.
SYMBOL
up to 10 l/min
up to 350 bar
D 5.148.1 /05.11
UNF
MODEL CODE
WK06W – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
DIMENSIONS
Cavity
FC06-2
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Standard models
Code Part No.
WK06W-01-C-N-0 without coil 2610182
(coil please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
2/2 Solenoid Directional valve
Spool type, direct acting,
Cartridge-Minivalve – 350 bar
WK06V-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coil easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 15 l/min
Leakage: < max. 90 cm³/min at 207 bar
and 28 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTFd: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-2
Weight: Complete valve: 0,170 kg
Coil only: 0,088 kg
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
Switching time: Energized: approx. 50 ms
De-energized: approx. 35 ms
FUNCTION
In de-energized mode the valve is
open in both directions.
If energized, the valve closes and
blocks the flow in both directions.
SYMBOL
up to 15 l/min
up to 350 bar
D 5.156.1 /05.11
1
2
UNF
MODEL CODE
WK06V – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
DIMENSIONS
Cavity
FC06-2
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Standard models
Code Part No.
WK06V-01-C-N-0 without coil 2610222
(coil please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH062-SS4 2600490 steel, zinc plated SAE-4 420 bar
FH062-AS4 2600491 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610184
Seal kit-FKM 2610185
Tools
Code Part No.
Rougher 2582046
Finisher 2582047
3/2 Solenoid Directional Valve
Spool type, direct acting
Cartridge-Minivalve – 350 bar
WK06C-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coil easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 10 l/min
Leakage: < max. 90 cm³/min at 207 bar and
28 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-3
Weight: Complete valve: 0,175 kg
Coil only: 0,088 kg
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a
rectifier built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
Switching time: Energized: approx. 30 - 60 ms
De-energized: approx. 20 - 40 ms
FUNCTION
In de-energized mode there is free
flow from port 1 to 2 and in the
opposite direction. Port 3 is closed.
If energized, the valve allows flow
from port 2 to 3 and in the opposite
direction. Port 1 is closed.
SYMBOL
up to 10 l/min
up to 350 bar
D 5.149.1 /05.11
UNF
MODEL CODE
WK06C – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
DIMENSIONS
Cavity
FC06-3
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Standard models
Code Part No.
WK06C-01-C-N-0 without coil 2610183
(coil please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH063-SS4 2600493 steel, zinc plated SAE-4 420 bar
FH063-AS4 2600492 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610186
Seal kit-FKM 2610187
All dimensions in inch (mm)
Subject to technical modification
Tools
Code Part No.
Rougher 2582050
Finisher 2582051
4/2 Solenoid Directional Valve
Spool type, direct acting
Cartridge-Minivalve – 350 bar
WK06Y-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coil easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
Nominal flow: max. 10 l/min
Leakage: < max. 100 cm³/min at 207 bar and
28 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +12C)
Support rings: PTFE
Cavity: FC06-4
Weight: Complete valve: 0,190 kg
Coil only: 0,088 kg
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
Switching time: Energized: approx. 30 - 60 ms
De-energized: approx. 20 - 40 ms
FUNCTION
In de-energized mode, the valve
allows flow from port 1 to 2 and from 3
to 4 and also in the opposite direction.
If energized, the valve allows flow
from port 1 to 4 and from 3 to 2 and
also in the opposite direction.
SYMBOL
up to 10 l/min
up to 350 bar
D 5.150.1 /05.11
UNF
MODEL CODE
WK06Y – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
DIMENSIONS
Cavity
FC06-4
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Standard models
Code Part No.
WK06Y-01-C-N-0 without coil 2610203
(coil please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH064-SS4 2600461 steel, zinc plated SAE-4 420 bar
FH064-AS4 2600462 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610188
Seal kit-FKM 2610189
Tools
Code Part No.
Rougher 2582057
Finisher 2582058
4/3 Solenoid Directional Valve
Spool type, direct acting
Cartridge-Minivalve – 350 bar
WK06E-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coils easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
max. 210 bar at Tank (port 1)
Nominal flow: max. 11 l/min
Leakage: < max. 100 cm³/min at 207 bar and
28 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-4
Weight: Complete valve: 0,374 kg
Coil only: 0,088 kg (2x)
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
Switching time: Energized: approx. 30 - 60 ms
De-energized: approx. 20 - 40 ms
FUNCTION
In de-energized mode all ports are
blocked.
If the coil S1 is energized, there is
free flow from port 3 to 4 and from 2
to 1.
If the coil S2 is energized, there is
flow from port 3 to 2 and from 4 to 1.
SYMBOL
S1 S2
up to 11 l/min
up to 350 bar
D 5.151.1 /05.11
UNF
DIMENSIONS
Cavity
FC06-4
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
Standard models
Code Part No.
WK06E-01-C-N-0 without coil 2610190
(coils please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH064-SS4 2600461 steel, zinc plated SAE-4 420 bar
FH064-AS4 2600462 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610188
Seal kit-FKM 2610189
MODEL CODE
WK06E – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
01A = lockable manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
Tools
Code Part No.
Rougher 2582057
Finisher 2582058
4/3 Solenoid Directional Valve
Spool type, direct acting
Cartridge-Minivalve – 350 bar
WK06G-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coils easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
max. 210 bar at Tank (port 1)
Nominal flow: max. 7 l/min
Leakage: < max. 100 cm³/min at 207 bar and
28 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +12C)
Support rings: PTFE
Cavity: FC06-4
Weight: Complete valve: 0,374 kg
Coil only: 0,088 kg (2x)
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
FUNCTION
In de-energized mode the ports 2 and
4 are blocked – whereas there is flow
from port 3 to 1 and in opposite
direction.
If the coil S1 is energized, there is
flow from port 3 to 2 and from 4 to 1 .
If the coil S2 is energized, there is
flow from port 3 to 4 and from 2 to 1 .
SYMBOL
S1 S2
up to 7 l/min
up to 350 bar
D 5.152.1 /05.11
UNF
DIMENSIONS
Cavity
FC06-4
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
MODEL CODE
WK06G – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
01A = lockable manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
Standard models
Code Part No.
WK06G-01-C-N-0 without coil 2610192
(coils please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH064-SS4 2600461 steel, zinc plated SAE-4 420 bar
FH064-AS4 2600462 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610188
Seal kit-FKM 2610189
Tools
Code Part No.
Rougher 2582057
Finisher 2582058
4/3 Solenoid Directional Valve
Spool type, direct acting
Cartridge-Minivalve – 350 bar
WK06H-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coils easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
max. 210 bar at Tank (port 1)
Nominal flow: max. 9 l/min
Leakage: < max. 100 cm³/min at 207 bar and
28 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-4
Weight: Complete valve: 0,374 kg
Coil only: 0,088 kg (2x)
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
FUNCTION
In de-energized mode all ports are
connected.
If the coil S1 is energized, there is
flow from port 3 to 4 and from 2 to 1 .
If the coil S2 is energized, there is
flow from port 3 to 2 and from 4 to 1 .
SYMBOL
S1 S2
up to 9 l/min
up to 350 bar
D 5.153.1 /05.11
UNF
DIMENSIONS
Cavity
FC06-4
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
MODEL CODE
WK06H – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
01A = lockable manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage Plug with
suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
Standard models
Code Part No.
WK06H-01-C-N-0 without coil 2610193
(coils please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH064-SS4 2600461 steel, zinc plated SAE-4 420 bar
FH064-AS4 2600462 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610188
Seal kit-FKM 2610189
Tools
Code Part No.
Rougher 2582057
Finisher 2582058
4/3 Solenoid Directional Valve
Spool type, direct acting
Cartridge-Minivalve – 350 bar
WK06J-01
FEATURES
- All exposed surfaces corrosion-proof
- All valve parts made of high-strength steel with hardened and ground components
to ensure minimal wear and extended service life
- Coil seals protect the solenoid system
- Coils easy to exchange and pivotable
SPECIFICATIONS
Operating pressure: max. 350 bar
max. 210 bar at Tank (port 1)
Nominal flow: max. 11 l/min
Leakage: < max. 100 cm³/min at 250 bar and
34 mm²/s
Temperature range of operating fluid: Min. – 30°C up to max. +10C
Ambient temperature range: Min. – 30°C up to max. + 60°C
Fluid: Hydraulic fluid to DIN 51524 T1 + T2
Viscosity range: min. 7,4 mm²/s up to max. 420 mm²/s
Filtration: Class 21 / 19 /16 according
to ISO 4406 or cleaner
MTTF
d
: 150 years
Installation: no orientation restrictions
Materials: Valve body: high tensile steel
Piston: hardened and ground steel
Seals: NBR (Standard)
FKM (optional, temperature
range -20°C up to +120°C)
Support rings: PTFE
Cavity: FC06-4
Weight: Complete valve: 0,374 kg
Coil only: 0,088 kg (2x)
Electrical data
Type of voltage: DC coil, AC voltage is rectified by a rectifier
built-in the plug
Nominal current at 2C: 984 mA at 12 V DC
492 mA at 24 V DC
Voltage tolerance: +/- 15% of Coil voltage
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at 60°C
ambient temperature
FUNCTION
In de-energized mode the ports 2, 4
and 1 are connected, while port 3 is
blocked.
If the coil S1 is energized, there is
flow through the valve from port 3 to 4
and from 2 to 1.
If the coil S2 is energized, there is
flow from port 3 to 2 and from 4 to 1.
SYMBOL
up to 11 l/min
up to 350 bar
D 5.154.1 /05.11
UNF
DIMENSIONS
Cavity
FC06-4
PERFORMANCE
Measured at 28 mm²/s and T oil = 38°C
All dimensions in inch (mm)
Subject to technical modification
HYDAC Fluidtechnik GmbH
Justus-von-Liebig-Str. 5
66280 Sulzbach / Saar
Tel.: 06897 / 509 -0
Fax: 06897 / 509 -598
Email: flutec@hydac.com
MODEL CODE
WK06J – 01M – C – N – 24 DN
Basic model
Directional Spool type, direct acting
Type
01 = Standard
01M = manual override
01A = lockable manual override
Body & ports
C = cartridge only
*versions in line bodies on request
Seals
N = NBR (Standard)
V = FKM (optional)
Coil voltage
0 = without coil (with nut and Seals)
DC: 12 = 12 Volt DC voltage
24 = 24 Volt DC voltage
AC: 115 = 105 Volt DC voltage
230 = 205 Volt DC voltage (at AC voltage
Plug with suppressor diode necessary Mat. 2600582)
Coil connector (Coil... 32-1329)
DC: DG = DIN Plug to EN175301-803 Form B
DL = 2 leadwires, 450mm long
DN = Deutsch Plug, axial (Type DT04-2P)
Standard models
Code Part No.
WK06J-01-C-N-0 without coil 2610191
(coils please choose from brochure D 5.155.0 )
Other types on request
*Line bodies
Code Part No. Material Ports Pressure
FH064-SS4 2600461 steel, zinc plated SAE-4 420 bar
FH064-AS4 2600462 Alu, anodized SAE-4 245 bar
other line bodies on request
Seal kits
Code Part No.
Seal kit-NBR 2610188
Seal kit-FKM 2610189
Tools
Code Part No.
Rougher 2582057
Finisher 2582058
FEATURES
-
- Maximal force at minimal space requirement,
by perfect wound coil - maximal copper : avoids damages of the insulation of the
wires (breakdown by short-circuits)
- Fully closed coil
internal coil sealing avoids humidity and short-circuits in the winding
- Designed for 100% coil duty rating
at Imax and ambient temperatures from –20°up to +60°C
- Small energy consumption
by optimal design of force – energy ratio
- High mechanical resistance,
by zinc plated steel cover
- High thermal stability,
to U.L. class N (18C)
- Standardized 4 different electrical connectors
with IP ratings IP65, IP67 and IP69K
DIN/EN Plug (G) IP65 Form B, Weather Pack (W) IP65/IP67,
leadwires (L) IP65/IP67//IP69K, Deutsch Plug (N) IP65/IP67/IP69K
others on request
- Mounting direction optional,
by symmetrical coil design
- Coil dimension = typification
Type 32-1329 = 32mm high (13 mm inside Ø, 29 mm outside Ø)
SPECIFICATIONS
Coil duty rating: 100% continuous up to max.
115% of Coil voltage at max. 60°C
ambient temperature
Max. permitted temperature at coil: 160°C
Power intake: 12 W at Imax and 20°C
coil temperature
Windings:
to U.L. class N (180°C)
Outer shell: steel, zinc plated
Plug socket: Polyamide, black
(All data are valid for a coil mounted on valve)
Connector type W (without picture)
Weather Pack, 2-polig
Connector type N
Deutsch Plug, 2-poles (Type DT04-2P)
Connector type L
2 leadwires, 450mm long
Connector type G
DIN Plug to EN175-301-803
Form B
Coils for Minivalves
(for solenoid operated directional valves)
Type 32-1329
for following valves: WS06Z WS06Y
WK06W WK06C
WK06Y WK06E
WK06G WK06H
WK06J
D 5.155.1 /05.11
MODEL CODE
Coil 12 DG01 32 -1329
Basic model
Coil voltage
12 V DC
24 V DC
105 V DC (Only Connector type DG)
205 V DC (Only Connector type DG) (at AC voltage
Plug with suppressor diode necessary Mat. 2600582)
Type of voltage
D = DC voltage DC, directional valve
A = AC voltage AC, directional valve
Coil connectors
G = Plug to EN175301-803 Form B, IP rating IP65
W = Weather Pack 2-poles, IP rating IP65/IP67
L = 2 leadwires, 0,75mm², 450mm (18“) long
IP rating IP65 /IP67/IP69K
N = Deutsch Plug, 2-poles, IP rating IP65/IP67/IP69K
Other coil connectors on request
Variation (depending on connector)
omission = Standard
01, 02... = e. g. suppressor diode, different cable lengths, etc...
others on request
Typification
32-1329 = main measures (Height, inner diameter, outer diameter)
The model code only serves for your information, available products see chart.
HYDAC Fluidtechnik GmbH
Juistus-von-Liebig-Str.
D-66280 Sulzbach/Saar
Tel. 06897 / 509-01
Fax 06897 / 509 598
E-Mail: flutec@hydac.com
Description
In general the coil is produced as DC coil.
For DC coils with DIN-Connector to EN
175301-803 Form B a separate plug
(Part no. 2600570) is available.
For AC voltage and DIN-Connector to EN
175301-803 Form B a plug (Part no.
2600582) with integrated rectifier is
available.
Codes and corresponding Part No's.
Nominal Coil Coil Resis- Nominal Part No's for connector
voltage
length in mm
power tance current
DIN Weather Pack leadwires Deutsch
(Volt) (mm) (Watt) (Ohm) (Amp.) (G) (W) (L) (N)
2610160 2610287 2610151 2610149
2610161 2610288 2610162 3012599
2610156* -- -- --
2610159* -- -- --
12 V DC
24 V DC
115 V AC*
230 V AC* 32 3700,00 0,0612,00
32 980,00 0,1112,00
32 48,70 0,4912,00
32 12,20 0,9812,00
* If using AC voltage a plug (Part no. 2600582) with rectifier is necessary
Annotation
The technical information in this
brochure are relating to the
operating conditions and
applications.
At deviant applications and/or
operating conditions please
contact
the technical dept.
Technical information are
subject to technical modifications.