1
1
HPC07_2016-04-12
Pressure Reducing Valve HPC07-DV
Technical Data
Nominal Flow 38 l/min
Reduced Pressure Range 3,5 - 207 bar (50,8 PSI to 3000 PSI)
Viscosity Range 3 - 650 cSt
Filtraon 8/16/13
Viscosity Range 10 – 350 cSt
Media operang Temp. Range -40 °C – +120 °C
Installaon cavity T007
Cartridge Torque Requirements 40,6 Nm
Electrical Specicaon 24 VDC Motor with 250:1 rao gear box
Actuaon Time 23 ± 3 seconds at 24 VDC
Weight 0,3 kg
HPC07 200DV G024V MP
Design
Proportional
Cartridge
Valve, Size 07
Function
DV
Pressure
Reducing Valve
Nominal Voltage
G012
12 VDC
G024
24 VDC
Actuation
MP
DC-Motor,
planet gear
Seal
N
NBR
V
Viton
* Pressure Range
200
207 bar
The Valve can adjusted to any posion between
fully open and fully closed applying electrical power
to the motor.
Actuaon:
24 VDC to blue wire to increase pressure seng
24 VDC to brown wire to decrease pressure seng
When a pre-determined pressure
is reached at (3), the spool shis
to restrict input ow at (2),
thereby reducing ow.
If valve and pressure at port (3)
exceeds seng, spool shi to
open passage at port (1), thereby
regulang pressure at port (3) by
relieving excess ow.