1
1
HPC07_2016-04-12
Pressure Reducing Valve HPC07-DV
Technical Data
Nominal Flow 38 l/min
Reduced Pressure Range 3,5 - 207 bar (50,8 PSI to 3000 PSI)
Viscosity Range 3 - 650 cSt
Filtraon 8/16/13
Viscosity Range 10 – 350 cSt
Media operang Temp. Range -40 °C – +120 °C
Installaon cavity T007
Cartridge Torque Requirements 40,6 Nm
Electrical Specicaon 24 VDC Motor with 250:1 rao gear box
Actuaon Time 23 ± 3 seconds at 24 VDC
Weight 0,3 kg
HPC07 200DV G024V MP
Design
Proportional
Cartridge
Valve, Size 07
Function
DV
Pressure
Reducing Valve
Nominal Voltage
G012
12 VDC
G024
24 VDC
Actuation
MP
DC-Motor,
planet gear
Seal
N
NBR
V
Viton
* Pressure Range
200
207 bar
The Valve can adjusted to any posion between
fully open and fully closed applying electrical power
to the motor.
Actuaon:
24 VDC to blue wire to increase pressure seng
24 VDC to brown wire to decrease pressure seng
When a pre-determined pressure
is reached at (3), the spool shis
to restrict input ow at (2),
thereby reducing ow.
If valve and pressure at port (3)
exceeds seng, spool shi to
open passage at port (1), thereby
regulang pressure at port (3) by
relieving excess ow.