TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
1
Specifications are subject to change without notice.
FLUID-SYSTEM is a leader in the design of anti-slipping system (registered patent) for hydrostatic transmissions
and will put its experience to work for you.
The flow divider is a slip preventing system for all types of hydrostatic transmissions. It provides 100%, on
demand traction for any field configuration.
FLUID-SYSTEM's flow divider is designed to suit the highest of performance and safety standards for all of our
clients.
The bidirectional flow divider controls the speed between wheels of the same axle, or between different axles
by dividing or combining the flow. It is equipped with an electric or hydraulic controlled bypass that enables a
higher operating speed on the road. It can be equally used on open or closed loop circuits.
FLUID-SYSTEM flow divider versatility allows for different installation options on many types of hydrostatic
transmissions.
Up to 450 bar [6527 psi]
Up to 150 l/min [39.6 gpm]
Direct in-line mounting, depending on
system configuration
Threaded connections :
o ISO 1179 (BSPP/Gas)
o ISO 11926 (UNF)
Open or closed loop circuits
Can work by dividing or combining the
flow
2 WAY FLOW DIVIDER - Spool size 20
DESCRIPTION
S
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
2
Designed to reduce the installation and operation costs
Robust and reliable
No need for maintenance: cost savings and reduced risk of equipment failure
Cost-effective solution
Flows can be added or divided with precision
Flow ratio can be adjusted to customer need
Large range of options
Long life span
Rigorously designed; bench and field tested
BENEFITS
HYDRAULIC SCHEMATIC
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
3
Can be found in many configurations:
1 solenoid valve (as shown above)
2 solenoid valves
3 solenoid valves (by special request)
4 solenoid valves
Each additional solenoid valve added after the first one enables the control of other functions like a feeding
pump, a brake, a speed control, a selector, etc...
To obtain a specialized configuration technical specifications sheet, please contact our team.
OVERALL DIMENSIONS
Millimeter (Inches)
(5.32"max)
(6.50"max)
(4.45"max)
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
4
If you need to install a flushing valve in a closed loop circuit equipped with a flow divider, the flushing
valve must be installed between the pump and the flow divider.
Maximum Flow
150 l/min (39.6 gpm)
Operating Pressure
450 bar (6527 psi)
Piloting Pressure
Min 8 bar (116 psi) - Max 50 bar (725 psi) *
Maximum Pressure
500 bar (7255 psi)
Operating Temperature
-20°C to 80°C (32°F to 176°F)
Seals
NBR **
Threaded Connections
ISO 1179 (BSP/Gas) - ISO 11926 (UNF)
Weight
8.9 kg (19.6 lbs)
Material
Steel
Viscosity
Between 10 and 100 cst
Pollution Level
20/18/15 as per ISO 4406
Surface Treatment
Phosphatation
* Values can be changed upon request to our engineering department.
** Other seals available on demand.
INSTALLATION WARNING
TECNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
5
Size
Max Flow
Ports
European Threades
Connections
ISO 1179-1
US Threaded
Connections
ISO 11926-1
Protective
Cap
20
150 l/min
T G1
3/8" BSP
3/4" - 16 UNF- 2B
Plastic
A, B
1/2" BSP
7/8" - 14 UNF- 2B
Plastic
P
3/4" BSP
1 1/16" - 12 UNF-2B
Plastic
a. DIVISION SPECIFICATIONS
Division ratio can be : 50/50 70/30 80/20
The precision is determined by the pressure difference of 150 bar (2176 psi) between A and B,
without orifice and with a ratio of 50/50; it is equal to:
QA QB
QP QP
PORT TABLE
SPECIFICATION CURVES
% incoming flow
%
division
accuracy
ou
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
6
b. PRESSURE DROP
Bypass mode
Division mode
The total pressure drop corresponds to the loss at the transfer restrictor boundaries increased by the loss of
the block itself.
Test conditions: HV 46 hydraulic fluid at 40°C [104°F]
5 bar
(72.5 psi)
Max flow
Outlet flow l/min (gpm)
Pressure drop bar (psi)
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
7
c. TRANSFER RESTRICTOR (with orifice size)
It is located between the two outlets.
Transfer restrictor calculation:
d. CHECK VALVES ON FEEDING SYSTEM
In some applications, a receiver located in front of the flow divider can use a higher flow than the one supplied.
In this case, the oil is brought back in the line in order to protect the components from cavitation.
When a vehicle equipped with a hydrostatic transmission takes a turn, the external wheel must turn faster than
the interior one. If the divider is installed between the right and the left wheels and is activated (without the
bypass mode) while taking the turn, the check valves on the feeding system can be useful.
Note: Trials will confirm the required sizing for the application.
Nominal flow is aroud 40 l/min (10.6 US gpm) with a loss not exceeding 6 bar (87 psi).
S Section
Q
Dp
bar
l /min
Restrictor shape
(0.65 1.5)
cm
2
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
8
1
2
3
4
5
6
7
8
9
10
11
12
13
D
B
-
-
-
-
-
-
-
-
-
-
-
-
Function (1)
Transfer restrictor (7) from
A to B
Connection (12)
DB
Flow divider
01
Standard UNF
00
Without
02
BSP option
Operation way (2)
06
0,6 mm (0.024 in)
XX
Upon request
DE
Bidirectional
08
0,8 mm (0.031 in)
10
1 mm (0.039 in)
Special design (13)
XX
Upon request
NNN
Sans
No. of branches (3)
1
Branch protection HP (8)
2
2X
3
00
without
4
30
300 bar (4353 psi)
38
380 bar (5514 psi)
Max flow (4)
42
420 bar (6094 psi)
Size
Max Flow*
XX
Upon request
20
200
28
300
By pass (9)
XX
Upon request
01
Hydraulic
02
Electrical 12V
Divided flow** (5)
03
Electrical 24V
010
10 l/min
XX
Upon request
020
20 l/min
040
40 l/min
Accessories (10)
080
80 l/min
00
without
150
150 l/min
01
1 accessory
xxx
Upon request
02
2 accessories
03
3 accessories
Division ratio (6)
XX
Upon request
50 - 50
70 - 30
Supply Voltage (11)
80 - 20
NN
Without
60 - 40
12
12 V
75 - 25
24
24 V
55 - 45
XX
Upon request
XX - YY (upon request)
* in by-pass mode
** Flow for which division ratio is optimum
PRODUCT CODE
TECHNICAL SPECIFICATIONS 2 WAY FLOW DIVIDER - 20
DISTRIBUTOR : Fluidesign Group
4, rue du moulin Cuzieu
42420 LORETTE
Tél: +33(0) 4 77 73 70 70
Fax:+33(0) 4 77 73 70 79
www.fluidesign-group.com
Last update : 28/10/2015
9
WITH HYDRAULIC CONTROL
WITH ELECTROHYDRAULIC CONTROL
Excavation machinery
Paved road sweepers
Forestry equipment
Harvesting machinery
Agricultural machinery
Self-propelled mowers
Lifting cranes
Transmission circuit examples (Flow divider with integrated pressure supply valves)
Flow divider operating as a wheel separator (Pst) with
integrated pressure supply valves and supply port (S).
Flow divider operating as an axis separator with
integrated pressure supply valves and supply port (S).
Note: If you need to install a flushing valve in a closed loop circuit equipped with a flow divider, the flushing
valve must be installed between the pump and the flow divider. If necessary please consult us.
With electric controls, direct-acting, with spool valve, hydraulic screw distributor…
APPLICATIONS
ACCESSORIES