FR1 SERIES 5/8
HYDRAULIC DIVISION FR1 SERIES
ELEMENT PRESSURE DROP
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below
corresponding to the selected media and divided by 1000.
If the oil has a viscosity V
1
different than 32 cSt a corrective factor V
1
/32 must be applied.
Example: 80 l/min with R130G10B and oil viscosity 46 cSt > 80 x 3,19/1000 x 46/32 = 0,36 bar
EXAMPLE OF TOTAL ∆p CALCULATION
FR130G10BBB60C000 with 80 l/min and oil 46 cSt:
Housing ∆p 0,01 bar + element ∆p 0,36 bar (80 x 3,19/1000 x 46/32) = total assembly ∆p 0,37 bar
G06 G10 G15 G25 G40 C10 C25 T60 M05 M10 M15
R110 33,84 15,68 12,50 8,81 4,54 4,83 4,13 2,56 10,46 8,94 5,58
R111 12,28 7,32 4,48 4,28 2,27 2,74 2,06 0,81 4,79 4,09 2,00
R120 13,85 8,65 6,44 6,32 2,77 4,09 2,52 0,86 5,65 4,83 3,19
R122 7,80 5,27 3,92 3,60 1,55 2,70 1,41 0,76 3,83 3,27 1,79
R130 5,09 3,19 2,25 2,06 0,90 1,64 0,82 0,49 2,31 1,98 1,02
R131 3,34 1,94 1,37 1,26 0,46 1,06 0,42 0,24 1,41 1,20 0,63
R140 2,43 1,31 1,25 1,10 0,43 0,85 0,39 0,22 0,95 0,82 0,62
R143 2,25 1,21 1,15 1,00 0,39 0,83 0,35 0,20 0,88 0,75 0,57
R150 2,16 1,12 1,08 0,96 0,37 0,82 0,34 0,19 0,81 0,69 0,54
R151 1,80 0,88 0,77 0,71 0,29 0,64 0,26 0,15 0,64 0,55 0,38
R160 1,49 0,74 0,71 0,51 0,25 0,45 0,23 0,10 0,54 0,46 0,35
R164 1,32 0,52 0,45 0,42 0,13 0,36 0,12 0,10 0,38 0,32 0,21
BYPASS VALVE PRESSURE DROP
The bypass valve ∆p is given by the curve of the considered model and setting, in correspondence of the flow rate
value.
FR110-31
FR140-64