EATON Vickers Screw-In Cartridge Valves V-VLOV-MC001-E4 September, 2007H-8
10
15
20
100
200
300
5
0
A
B
Flow – L/min (21,8 cSt oil @ 49 °C)
Flow – USgpm (105 SUS oil @120 °F)
40 60 80 1000 20
10 15 20 25 300 5
Pressure Drop – psi
Pressure Drop
– bar
A - Piloted open port 1 to port 2
B - Free flow port 2 to port 1
RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49˚C (120˚F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
Cracking pressure @ 1 L/min (0.25 USgpm) 30 - 62-210 bar (900-3000 psi)
50 - 186-350 bar (2700-5000 psi)
Internal leakage 5 drops/min. max. Port 1 to Port 2 @ 77% of crack pressure
Temperature range -40˚ to 120˚C (-40˚ to 248˚F)
Cavity C-12-3S
Pilot ratio 4:1, 10:1
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/
1166//1133
Standard housing materials Aluminum or steel
Weight cartridge only 0,36 kg. (0.79 lbs.)
Seal kit 02-180095 Buna-N
02-165887 Viton
®
Viton is a registered trademark of E.I. Dupont
Functional Symbol
Sectional View
Pressure Drop Curves
Cartridge only
CBV1/2-12
Counterbalance valve
For 4:1 Ratio
Pilot pressure, =
Cracking pressure + (5 x Port 2 pressure) - Port 1 pressure
4
For 10:1 Ratio
Pilot pressure, =
Cracking pressure + (11 x Port 2 pressure) - Port 1 pressure
10
Description
The CBV*-12 is a 3-ported,
externally piloted, screw-in
cartridge type counterbal-
ance valve.
Operation
The counterbalance valve
allows free flow from port 2
to port 1. Flow from port 1
to port 2 is blocked until
either the predetermined
pressure setting has been
reached or sufficient pilot
pressure has been applied
to port 3 (pilot).
WARNING
For pressure over
210 bar (3000 psi)
use steel housing.
CAUTION
Adjustments
exceeding 350 bar
(5000 psi) may
damage the body.
1800-232-0646 (Intl.) +1-206-319-9433
1800-232-0646 (Intl.) +1-206-319-9433