Proportional Two-Stage Directional Valves
Servo Performance with Double Spool Feedback
Pressures to 350 bar (5000 psi)
KBHDG5V-5/7/8/10
11 Design
2
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Contents
Introduction
General Description 3
Features and Benefits 3
Typical Section 3
Model Code 4
Spool Data 5
Functional Symbol 5
Operating Data 6
Pressures and Minimum Flow Rates 7
Performance Curves
Power Capacity Envelope 8
Pressure Gain 8
Frequency Response 8
Flow Gain 9
Dimension KBHDG5V-5/7/8/10 12
Mounting Surface Interface KBHDG5V-5/7/8/10 14
Electrical Information
Block Diagram 16
Typical Connection Arrangements 18
Application Data
Fluid Cleanliness 20
Hydraulic Fluids 20
Installation 20
Mounting Bolt Kits 20
Seal Kits 20
Electrical Connectors 20
Extension Cable 20
Service Information 20
Released Model Codes 21
3
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Introduction
General Description
Vickers proportional valves
shown in this catalog are
suitable for working pres-
sures up to 350 bar (5000
psi) and flow rates to 720
l/min (190 USgpm).
They are designed to provide
a controlled oil flow in pro-
portion to a command signal,
with spool position feedback
to provide accurate control.
Zero lapped spools are avail-
able for closed loop control
applications and hydrostats
are available for load com-
pensation.
KBHDG5V-5/7/8/10
A range of proportional direc-
tional valves with control
amplifiers built directly on,
and prewired to the valves.
Factory-set adjustments of
gain, spool deadband com-
pensation, and offset ensure
high valve-to-valve repro-
ducibility.
The only electrical inputs
required are power supply
(24V) and a voltage com-
mand signal of ±10V. The
amplifier is housed in a
robust metal enclosure,
sealed against ingress of
water and other fluids.
Electrical connections are via
a standard 7-pin plug.
A spool position monitor
point allows the function of
the valve to be electrically
monitored. Ramp functions,
if required, can be generated
externally.
Features and Benefits
Factory-sealed adjust-
ments increase valve-to-
valve reproducibility.
Valve with integrated
amplifier selected,
ordered, delivered and
installed as one perform-
ance-tested package.
Electronic feedback LVDT
ensures accurate spool
position control.
Vibration and shock tested.
Standard 24V DC supply
with wide tolerance band.
Wide range of spool and
flow rate options.
Standard ± 10 V DC and
4-20mA command signals.
Installation wiring reduced
and simplified.
Standard 7-pin connector.
Simple valve removal and
replacement for service.
Supported by auxiliary
function modules.
Full CE electromagnetic
compatibility.
IP65 and IP67 environmen-
tal protection rating.
Optional valve enable func-
tion.
Optional pilot pressure
reducer.
Typical Section View
KBHDG5V-7, 10 design
4
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Model Code
Valve type
K – Proportional valve
Integral amplifier
B – Integral amplifier “B”
series
Feed back arrangement
H – From pilot and main
stages
Control type
D - Directional valve
Mounting
G – Subplate mounted
Operation
5 – Solenoid controlled, pilot
operated
Pressure rating
V – 310 bar (4500 psi) Size 05
– 350 bar (5000 psi) Size 07
– 350 bar (5000 psi) Size 08
– 350 bar (5000 psi) Size 10
Interface
ISO 4401
5 – Size 05
7 – Size 07
8 – Size 08
10 – Size 10
Spool type, flow rating
and metering
See “Functional Symbol” on
page 5. p = 5 bar (72 psi) per
metering flow path, e.g. B to T.
SYMMETRIC SPOOLS
For KBHDG5V-5 valves:
2C100N – 100 L/min
(26 US gpm)
33C80N – 80 L/min
(21 US gpm)
5C85N – 85 L/min
(22 US gpm)
For KBHDG5V-7 valves:
2C200N – 200 L/min
(52 US gpm)
33C160N – 160 L/min
(42 US gpm)
5C200N – 200 L/min
(52 US gpm)
For KBHDG5V-8 valves:
2C375N – 375 L/min
(99 US gpm)
33C375N – 375 L/min
(99 US gpm)
5C375N – 375 L/min
(99 US gpm)
For KBHDG5V-10 valves:
2C700N – 700 L/min
(185 US gpm)
33C700N – 700 L/min
(185 US gpm)
5C720N – 720 L/min
(190 US gpm)
ASYMMETRIC SPOOLS
First figure (***N) is flow rating
P-A, or A-T (“A” port flow); last
figure (N***) is flow rating P-B,
or B-T (“B” port flow)
For KBHDG5V-5 valves:
2C70N45 – 70 L/min
(18.5 US gpm), A” port flow
45 L/min (11.9 US gpm), “B”
port flow
33C60N40 – 60 L/min (17.2
US gpm), A” port flow
40 L/min (10.6 US gpm), “B”
port flow
PQ87F - See flow charts (p.9)
For KBHDG5V-7 valves:
2C150N85 – 150 L/min
(40 US gpm), A” port flow;
85 L/min (22.4 US gpm), “B”
port flow
33C130N65 – 130 L/min
(33.3 US gpm), A” port flow;
65 L/min (17.2 US gpm), “B”
port flow
5C200N115 – 200 L/min (52.8
US gpm), A” port flow; 115
L/min (30.8 US gpm), “B” port
flow
PQ190F - See flow charts (p.9)
For KBHDG5V-8 valves:
2C375N250 – 375 L/min
(99 US gpm), A” port flow;
250 L/min (66 US gpm),
“B” port flow
12C375N250 – 375 L/min
(99 US gpm), A” port flow;
250 L/min (66 US gpm),
“B” port flow
33C375N250 – 375 L/min
(99 US gpm), A” port flow;
250 L/min (66 US gpm),
“B” port flow
133C375N250 – 375 L/min
(99 US gpm), A” port flow;
250 L/min (66 US gpm),
“B” port flow
733C375N250 – 375 L/min
(99 US gpm), A” port flow;
250 L/min (66 US gpm),
“B” port flow
72C375N250 – 375 L/min
(99 US gpm), A” port flow;
250 L/min (66 US gpm),
“B” port flow
PQ375F - See flow charts (p.10)
For KBHDG5V-10 valves:
2C700N420 – 700 L/min
(185 US gpm), A” port flow;
420 L/min (110 US gpm),
“B” port flow
33C700N420 – 700 L/min
(185 US gpm), A” port flow;
420 L/min (110 US gpm),
“B” port flow
12C700N420 – 700 L/min
(185 US gpm), A” port flow;
420 L/min (110 US gpm),
“B” port flow
133C700N420 – 700 L/min
(185 US gpm), A” port flow;
420 L/min (110 US gpm),
“B” port flow
72C700N420 – 700 L/min
(185 US gpm), A” port flow;
420 L/min (110 US gpm),
“B” port flow
733C700N420 – 700 L/min
(185 US gpm), A” port flow;
420 L/min (110 US gpm),
“B” port flow
PQ680 F - See flow charts (p.11)
For actual maximum flows
refer to power capacity
envelopes, page 8.
Pilot supply
BlankInternal (without reducer)
E – External (without reducer)
X – Internal (with reducer)
EX– External (with reducer)
See section on maximum
pressures (page 7) for when
pilot reducer must be used.
Pilot drain
T – Internal
Omit for external drain
Electrical Control Signal
M1 – ±10 demand signal,
±10V monitor signal
M2 – 4-20mA demand signal,
±10V monitor signal
M3 – ±10V demand signal,
4-20mA monitor signal
M4 – 4-20mA demand signal,
4-20mA monitor signal
Electrical connection
PC7 – 7 pin connector
without plug
PE7 – 7 pin connector
with plug
PH7 – As PE7 but with pin
“C” used for enable signal
PR7 – As PC7 but with pin
“C” used for enable signal
Coil rating
H – 24 VDC amplifier supply
Port T pressure limit
rating
4 – 50 bar (700 psi) (for
internal pilot drain option only,
item 11 above)
Design number
11 – 11 series
12
16
15
14
13
11
10
9
8
7
6
5
4
3
2
1
K B H D G 5 V – * – ********* – (E)X T ** *** – H 4 – **
1 2 3 4 5 6 7 8 10 11 12 13 14 15 169
WARNING
Valves with integral
amplifiers are sup-
plied with or without the
metal 7-pin plug. The Vickers
plug, part no. 934939, must
be correctly fitted to ensure
that the EMC rating and IP67
rating are achieved. The plug
retaining nut must be tight-
ened with a torque of 2-2,5
Nm (1.5-2.0 lbf ft) to effect a
proper seal.
5
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Spool Data
Spool Symbols
Spool code Spool symbol Flow rating
For KBHDG5V-5 valves:
2C100N 2C 100 L/min (26 USgpm)
33C80N 33C 80 L/min (21 USgpm)
5C85N 5C 85 L/min (22 USgpm)
For KBHDG5V-7 valves:
2C200N 2C 200 L/min (52 USgpm)
33C160N 33C 160 L/min (42 USgpm)
5C200N 5C 200 L/min (52 USgpm)
For KBHDG5V-8 valves:
2C375N 2C 375 L/min (99 USgpm)
33C375N 33C 375 L/min (99 USgpm)
5C375N 5C 375 L/min (99 USgpm)
For KBHDG5V-10 valves:
2C700N 2C 700 L/min (185 USgpm)
33C700N 33C 700 L/min (185 USgpm)
5C720N 5C 720 L/min (190 USgpm)
Spool Type and Flow
Ratings
Symmetric Spools
Base line pressure drop p = 5
bar (72 psi) per metering flow
path, e.g. B to T. For actual
maximum flow refer to power
capacity envelope curves.
Asymmetric Spools
Figure preceding metering
type designator, “N” e.g.
2C**N) is flow rating P–A, or
A–T (”A” port flow): Figure
after “N” (N***) is flow rating
P–B, or B–T (”B” port flow).
Note:
Valves with 5C spools are
designed so that with the
valve disabled the pressure
in port B is at least twice
that in port A (blocked ports).
Available Spools for KBHDG5V
AB
PT
AB
PT
Spool type 2C
AB
PT
Spool type 33C
Spool type 5C (zero lapped)
AB
PT
Spool type 72C
AB
PT
Spool type 733C
AB
PT
Spool type 133C
AB
PT
Spool type 12C
Application Notes
1. Main-Spool Options
Spools shown are meter-in/meter-out
types. Center-condition options are
types 2, 33, 5, 12, 133, 72, 733 and PQ.
2. Internally Piloted Models
Differ from detailed symbols above
by omission of plug A and the block-
ing of port X by the mating surface.
3. Internally Pilot Drain Models
Differ from detailed symbols above
by omission of plug B and blocking
of port Y by the mating surface.
A
T
B
P
Functional Symbol
7-pin
plug
ATBP
ATXBYP
ATBP
plug A plug B
Detailed Symbol
Symplified Symbol
AB
PT
Spool type PQ
Symmetric
Asymmetric
Spool code Spool symbol Flow rating
For KBHDG5V-5 valves:
2C70N45 2C 70 L/min (18.5 USgpm) “A” port flow
45 L/min (11.9 USgpm) ”B” port flow
33C60N40 33C 60 L/min (17.2 USgpm) ”A” port flow
40 L/min (10.6 USgpm) ”B” port flow
PQ87F PQ See flow chart (p. 9)
For KBHDG5V-7 valves:
2C150N85 2C 150 L/min (40 USgpm) “A” port flow
85 L/min (22.4 USgpm) ”B” port flow
33C130N65 33C 130 L/min (33.3 USgpm) “A” port flow
65 L/min (17.2 USgpm) ”B” port flow
5C200N115 5C 200 L/min (52.8 USgpm) “A” port flow,
115 L/min (30.8 USgpm) ”B” port flow
PQ190F PQ See flow chart (p. 9)
For KBHDG5V-8 valves:
2C375N250 2C 375 L/min (99 USgpm) “A” port flow
250 L/min (66 USgpm) ”B” port flow
33C375N250 33C 375 L/min (99 USgpm) “A” port flow
250 L/min (66 USgpm) ”B” port flow
12C375N250 12C 375 L/min (99 USgpm) “A” port flow
250 L/min (66 USgpm) ”B” port flow
133C375N250 133C 375 L/min (99 USgpm) “A” port flow
250 L/min (66 USgpm) ”B” port flow
72C375N250 72C 375 L/min (99 USgpm) “A” port flow
250 L/min (66 USgpm) ”B” port flow
733C375N250 733C 375 L/min (99 USgpm) “A” port flow
250 L/min (66 USgpm) ”B” port flow
PQ375F PQ See flow chart (p. 10)
For KBHDG5V-10 valves:
2C700N420 2C 700 L/min (185 USgpm) “A” port flow
420 L/min (110 USgpm) ”B” port flow
33C700N420 33C 700 L/min (185 USgpm) “A” port flow
420 L/min (110 USgpm) ”B” port flow
12C700N420 12C 700 L/min (185 USgpm) “A” port flow
420 L/min (110 USgpm) ”B” port flow
133C700N420 133C 700 L/min (185 USgpm) “A” port flow
420 L/min (110 USgpm) ”B” port flow
72C700N420 72C 700 L/min (185 USgpm) “A” port flow
420 L/min (110 USgpm) ”B” port flow
733C700N420 733C 700 L/min (185 USgpm) “A” port flow
420 L/min (110 USgpm) ”B” port flow
PQ680F PQ See flow chart (p. 11)
6
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Operating Data
Data is typical with fluid at 36 cSt (168 SUS) and 50 C (122 F).
Power supply 24V DC (21V to 36V including 10% peak-to-peak max. ripple)
max current 3A
Command signal
Voltage mode 0 to 10V DC, or 0 to –10V DC, or –10V to + 10V DC
Input impedance M1: 47 kΩ - M2: 100R
Common mode voltage to pin D 18V (max)
Current mode 4-20 mA
Max differential voltage to pin E to pin B 100 mV
Valve enable signal for model codes PH7 & PR7
Enable >8.5V (36V max)
Disable <6.5V
Input impedance 10 kΩ
7-pin plug connector Pin Description
A Power supply positive (+)
B Power supply 0V and current command return
C Not connected (PE7 & PC7)
C Valve enable (PH7 & PR7)
D Command signal (+V or current in)
E Command signal (-V or current GND)
F Output monitor
G Protective ground
View of pins of fixed half.
Electromagnetic compatibility (EMC): IEC61326-2-1
Threshold command voltage 0V – 5C Spools
(minimum voltage for minimum flow) 0.25V– 2C & 33C Spools
Monitor signal (pin F) ±10V DC for full spool stroke
Output impedance 10k
Power stage PWM frequency 10 kHz nominal
Step input response, with flow through P–A–B–T, p=5 bar
(72 psi) per metering path, e.g. P–A, pilot pressure = 40 bar
Required flow step: Time to reach 90% of required step:
KBHDG5V–5 KBHDG5V–7 KBHDG5V–8 KBHDG5V–10
0 to 100% 24 ms 24 ms 33 ms 64 ms
100% to 0 23 ms 23 ms 33 ms 60 ms
+90 to –90% 35 ms 36 ms 49 ms 84 ms
Reproducibility, valve-to-valve (at factory settings): 5%
Flow at 100% command signal
Hysteresis with flow through P-A-B-T <1%
Øp=5 bar (72 psi) per metering path (P–A or B–T)
Protection:
Electrical Reverse polarity protected
Environmental IEC 60529, Class IP65 & IP67
Ambient air temperature range for full performance 0° C to 70° C (32° F to 158° F)
Oil temperature range for full performance 0° C to 70° C (32° F to 158° F)
Minimum temperature at which valves will
work at reduced performance –20° C (–4° F)
Storage temperature range –25° C to +85° C (–13° F to +185° F)
Relative duty factor Continuous rating (ED = 100%)
Mass: kg (lb) approx. KBHDG5V–5 KBHDG5V–7 KBHDG5V–8 KBHDG5V–10
Valves with pressure reducer 10,15 (22.4) 11,4 (25.1) 17,05 (37.54) 44,3 (97.7)
Valves without pressure reducer 8,85 (19.5) 10,1 (22.2) 15,85 (34.84) 43,1 (95.1)
Supporting products:
Auxiliary electronic modules (DIN -rail mounting):
EHA-CON-201-A2* signal converter See catalog GB 2410B
EHD-DSG-201-A-1* command signal generator See catalog GB 2470
EHA-RMP-201-A-2* Ramp generator See catalog GB 2410A
EHA-PSU-201-A-10 Power supply See catalog GB 2410A
EHA-PID-201-A-20 PID controller See catalog GB 2427
F
A
G
B
C
D
E
7
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Model Pilot pressure Pilot drain
source connection P Port A&B Ports T Port X Port Y Port
External 315 (4500) 315 (4500) 210 (3000) 315 (4500) 50 (700)
Internal* 315 (4500) 315 (4500) 50 (700) 315 (4500) 50 (700)
External 315 (4500) 315 (4500) 210 (3000) 315 (4500) 50 (700)
Internal* 315 (4500) 315 (4500) 50 (700) 315 (4500) 50 (700)
External 350 (5000) 350 (5000) 350 (5000) 350 (5000) 50 (700)
Internal* 350 (5000) 350 (5000) 50 (700) 350 (5000) 50 (700)
External 350 (5000) 350 (5000) 350 (5000) 350 (5000) 50 (700)
Internal* 350 (5000) 350 (5000) 50 (700) 350 (5000) 50 (700)
Minimum recommended pilot operating pressure = 50 bar (700 psi)
* Internal drain is a non-preferred option
For pilot pressures 210 bar (3000 psi) a pilot pressure reducer is optional
For pilot pressures > 210 bar (3000 psi) a pilot pressure reducer must be used
Unused pilot port: Maximum pressure as shown
KBHDG5V–5
KBHDG5V–7/8/10
Pressure and
Minimum Flow
Rates
MAXIMUM PRESSURES, BAR (PSI) VALVES WITH PRESSURE REDUCER
External
Internal
External
Internal
Model Pilot pressure Pilot drain
source connection P Port A&B Ports T Port X Port Y Port
External 315 (4500) 315 (4500) 210 (3000) 210 (3000) 50 (700)
Internal* 315 (4500) 315 (4500) 50 (700) 210 (3000) 50 (700)
External 210 (3000) 315 (4500) 210 (3000) 210 (3000) 50 (700)
Internal* 210 (3000) 315 (4500) 50 (700) 210 (3000) 50 (700)
External 350 (5000) 350 (5000) 350 (5000) 210 (3000) 50 (700)
Internal* 350 (5000) 350 (5000) 50 (700) 210 (3000) 50 (700)
External 210 (3000) 350 (5000) 350 (5000) 210 (3000) 50 (700)
Internal* 210 (3000) 350 (5000) 50 (700) 210 (3000) 50 (700)
Minimum recommended pilot operating pressure = 50 bar (700 psi)
* Internal drain is a non-preferred option
For pilot pressures 210 bar (3000 psi) a pilot pressure reducer is optional
For pilot pressures > 210 bar (3000 psi) a pilot pressure reducer must be used
Unused pilot port: Maximum pressure as shown
KBHDG5V–5
KBHDG5V–7/8/10
MAXIMUM PRESSURES, BAR (PSI) VALVES WITHOUT PRESSURE REDUCER
External
Internal
External
Internal
Valve Size/Spool Code Min. Flow Rate L/min In
3
/min
KBHDG5V–5 0,5 30
KBHDG5V–7 1,0 60
KBHDG5V–8 1,5 91
KBHDG5V–10 3,0 180
MINIMUM RECOMMENDED FLOW RATES
FLOW GAIN
At Øp = 5 bar (72 psi) per metering path (e.g. P-A), with flow
through P-A-B-T or P-B-A-T. Percentage command signals
applicable for positive and negative values of command signal.
"2C" Spools
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0 20 40 60 80 100
KBHDG5V–5–2C100N
KBHDG5V–7–2C200N
KBHDG5V–8–2C375N
20
40
60
80
100
120
140
160
180
200
220
0
100
200
300
400
500
600
700
900
800
KBHDG5V–10–2C700N
At other Øp values, flow rates approximate to:Q
X
= Q
D
where Q
D
= Datum flow rate
Øp
D
= Pressure drop at datum flow rate
Øp
X
= Required p
Limited by valve power capacity.
Refer to curves on page 8.
Øp
X
Øp
D
"5C" Spools
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0 20 40 60 80 100
KBHDG5V–5–5C100N
KBHDG5V–7–5C200N
KBHDG5V–8–5C375N
20
40
60
80
100
120
140
160
180
200
220
0
100
200
300
400
500
600
700
900
800
KBHDG5V–10–5C720N
"33C" Spools
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0 20 40 60 80 100
20
40
60
80
100
120
140
160
180
200
220
0
100
200
300
400
500
600
700
900
800
KBHDG5V–10–33C700N
KBHDG5V–5–33C80N
KBHDG5V–7–33C160N
KBHDG5V–8–33C375N
8
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Performance
Curves
KBHDG5V-5/7/8/10
350
300
200
100
0
Flow rate – L/min
300 600 900 1200 1500 1800 2100
POWER CAPACITY ENVELOPE
Flow through P-A-B-T or P-B-A-T
US gpm
160 240 320800 400 480
5000
4000
3000
2000
1000
psi
0
Valve Pressure drop – bar
560
KBHDG5V–7
KBHDG5V–5
KBHDG5V–8
KBHDG5V–10
Spool stroke
from null,
% of max.
1234 5 %12345
40
60
80
100
%
20
40
60
80
100
20
0
PRESSURE GAIN
(“5C” spools only)
between
ports A & B
or B & A, as %
of port P
pressure
12345102030406080
Amplitudes
Phase lags
Frequency (Hz)
+ 3
0
-1
-2
-3
-4
-5
-6
Amplitude ratio (dB)
Phase lag (degrees)
135
90
0
45
KBHDG5V–8
KBHDG5V–5/7
KBHDG5V–5/7
KBHDG5V–10
FREQUENCY RESPONSE, TYPICAL
For an amplitude of 50 ± 25% of rated flow (ISO 10770-1)
2C spool measured at = 36 cSt (168 SUS),
t = 50˚C (122˚F) and pilot pressure = 40 bar (with-reducer model)
KBHDG5V–10
KBHDG5V–08
(middle)
9
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
33
C
60N40
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0
10
20
30
40
50
60
70
80
0 2 0 4 0 6 0 8 0 100
0
3
5
8
11
13
16
19
21
P-B
A-T
B-T
P-A
2
C
150N85
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0
20
40
60
80
100
120
140
160
0 2 0 4 0 6 0 8 0 100
0
5
11
16
21
26
32
37
42
P-B
A-T
B-T
P-A
Performance
Curves
Flow Gain
33
C
130N65
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0
20
40
60
80
100
120
140
160
0 2 0 4 0 6 0 8 0 100
0
5
11
16
21
26
32
37
42
P-B
A-T
B-T
P-A
Flow rate – lpm
Flow rate – US gpm
Command si
g
nal (% of max.)
0
10
20
30
40
50
60
70
80
0 2 0 4 0 6 0 8 0 100
2
C
70N45
0
3
5
8
11
13
16
19
21
P-B
A-T
B-T
P-A
KBHDG5V-7
KBHDG5V-5
PQ87F
0
20
40
60
80
100
120
140
-100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Command signal (% of max.)
A-T
P-B
B-T
P-A
Flow rate – lpm
0
5
11
16
21
26
32
37
Flow rate – US gpm
PQ190F
0
50
100
150
200
-100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Command signal (% of max.)
A-T
P-B
B-T
P-A
Flow rate – lpm
250
Flow rate – US gpm
0
13
26
40
53
66
10
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
72C375N250 & 733C375N250
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0
50
100
150
200
250
300
350
450
400
0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
110
P-B
A-T
B-T
P-A
Performance
Curves
Flow Gain
12C375N250 & 133C375N250
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0
50
100
150
200
250
300
350
450
400
0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
110
P-B
A-T
P-A
2C375N250 & 33C375N250
Flow rate – lpm
Flow rate – US gpm
Command signal (% of max.)
0
50
100
150
200
250
300
350
450
400
0 20 40 60 80 100
10
20
30
40
50
60
70
80
90
100
110
P-B
A-T
B-T
P-A
PQ375F
0
50
100
150
200
250
300
350
450
400
-100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Command signal (% of max.)
A-T
P-B
B-T
P-A
Flow rate – lpm
Flow rate – US gpm
10
20
30
40
50
60
70
80
90
100
110
KBHDG5V-8
11
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
72C700N420 & 733C700N420
Flow rate – US gpm
0
100
200
300
400
500
600
700
900
800
0 20 40 60 80 100
2C700N420 & 33C700N420
Flow rate – US gpm
0
100
200
300
400
500
600
700
900
800
0 20 40 60 80 100
PQ680
0
100
200
300
400
500
600
700
900
800
-100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
12C700N420 & 133C700N420
Flow rate – US gpm
Command signal (% of max.)
0 20 40 60 80 100
20
40
60
80
100
120
140
160
180
200
220
Command signal (% of max.)
A-T
P-B
B-T
P-A
P-A
P-A
A-T
A-T
P-B
P-B
B-T
B-T
P-A
A-T
P-B
Flow rate – lpm
Flow rate – US gpm
Flow rate – lpm
Flow rate – lpm
Flow rate – lpm
0
100
200
300
400
500
600
700
900
800
20
40
60
80
100
120
140
160
180
200
220
20
40
60
80
100
120
140
160
180
200
220
20
40
60
80
100
120
140
160
180
200
220
Command signal (% of max.) Command signal (% of max.)
Performance
Curves
Flow Gain
KBHDG5V-10
12
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Installation
Dimensions
KBHDG5V-5/7
Dimensions shown in mm (in).
Mounting surface, seals supplied.
For mating surface dimensions, see page 14.
For mounting subplate options and bolt options,
see catalog GB-2425.
KBHDG5V-5
Valve without pressure reducer Valve with pressure reducer
Valve without pressure reducer Valve with pressure reducer
KBHDG5V-7
35,0
( 1 . 38)
70,0
(2. 76)
264,6
( 10. 42)
1 13,95
( 4 . 49)
202,83
( 7 . 99)
242,86
( 9 . 56)
141,6
( 5 . 57)
Air Bleed
Screw
Air Bleed
Screw
Pressure
Reducer
40.00 (1.58)
142,3
(5.60)
46,0
(1.81)
92,0
(3.62)
120,17
(4.73)
277,47
(10.92 )
250,69
(9.87)
210,83
( 8.30)
Air Bleed
Screw
Air Bleed
Screw
Pressure
Reducer
40.00 (1.58)
Mounting surface, seals supplied.
For mating surface dimensions, see page 14.
For mounting subplate options and bolt options,
see catalog GB-2425.
13
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Installation
Dimensions
KBHDG5V-8/10
Dimensions shown in mm (in).
KBHDG5V-8
267,1
[10.5]
Pressure
Reducer
40.00 (1.58)
Air Bleed
Screw
60.0
(2.36)
118.5
(4.66)
227.1
(8.94)
161.1
(6.34)
341.4
(13.44)
149.4
(5.88)
Air Bleed
Screw
Mounting surface, seals supplied.
For mating surface dimensions, see page 15.
For mounting subplate options and bolt options,
see catalog GB-2425.
Mounting surface, seals supplied.
For mating surface dimensions, see page 15.
For mounting subplate options and bolt options,
see catalog GB-2425.
98.40
(3.874)
196.80
(7.748)
280.93
(11.055)
507.21
(19.969)
133.67
(5.263)
Air Bleed
Screw
320.93
(12.635)
40.00
(1.58)
Air Bleed
Screw
Pressure
Reducer
225.72
(8.887)
KBHDG5V-10
Valve without pressure reducer Valve with pressure reducer
Valve without pressure reducer Valve with pressure reducer
14
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
2 holes Ø 4,0 (0.157 dia)
x 8,0 (0.31) min. depth
4 holes M10 x 17,0 (0.67)
min. full thread depth
2 holes M6-6H x 17,0 (0.67)
min. full thread depth
3 holes (ports L, X, Y)
Ø 6,3 (0.25 dia) max.
4 holes (ports P, T, A, B)
Ø 17,5 (0.69 dia) max.
95,0
(3.74)
min.
130,0 (5.12) min.
18,3
(0.72)
34,1 (1.34)
50,0 (1.97)
65,9 (2.59)
76,6 (3.016)
88,1 (3.47)
101,6 ± 0,1 (4.0 ± 0.004)
1,6 ± 0,1
(0.063 ± 0.004)
14,3 (0.56)
15,9
(0.63)
71,5
± 0,1
(2.815
± 0.004)
P
T
AB
X
Y
L
11,0
(0.43)
69,9
± 0,1
(2.75
± 0.004)
57,2
(2.25)
55,6
(2.19)
34,9
(1.38)
Mounting
Surfaces
Dimensions shown in mm (in).
General Description
When a subplate is not used,
a machined pad must be pro-
vided for valve mounting. Pad
must be flat within 0,0127
mm (.0005 inch) and smooth
within 1.6 mm (63 microinch).
Mounting bolts, when provid-
ed by customer, should be
ISO 898 class 12.9 or better.
Bolt Kits See page 18.
Dimensional Tolerances
Dimensional tolerance on
interface drawings is 0,2
mm ( 0.008”) except where
otherwise stated. ISO 4401
specifies inch conversion to
0.01”.
Conversion from Metric
ISO 4401 gives dimensions
in mm. Inch conversions are
accurate to 0.01” unless oth-
erwise stated.
Mounting Bolt Tappings
ISO 4401 gives metric thread
tappings. Alternate UNC tap-
pings are Vickers recommen-
dations that allow these
plates and associated valves
to be used up to their maxi-
mum pressures, when using
Vickers recommended bolt
kits, or bolts of an equivalent
strength. It is recommended
that Customer’s own mani-
fold blocks for UNC bolts
should be tapped to the min-
imum depths given in the
footnotes.
ISO Standard Size 05
without Ports X and Y
This interface conforms to
ISO 4401-05-04-0-05,
NSI/B93.7M (and NFPA) size
05, CETOP R35H4 2-05, DIN
24340 Form A10.
ISO Standard Size 05
with Ports X and Y
37,3 (1.47)
5 ports Ø 11,2 (0.44 dia)
including optional tank port
27,0 (1.06)
16,7 (0.66)
6,3 (0.25)
3,2 (0.12)
50,8 (2.0)
46,0 ± 0,1
(1.81 ± 0.004)
32,5
(1.28)
90,0 (3.54) min.
P
A
B
T
A
T
B
54,0 ± 0,1
(2.12 ± 0.004)
69,0
(2.72)
min.
21,4
(0.84)
Optional port
(T
B
)
4 holes, M6-6H x 16 (0.63)
min. full thread depth
P
A
T
A
T
B
62,0 (2.44)
8,0
(0.315)
11,0
(0.433)
X
Hole Ø 6,3 (0.25 dia) max.
Y
B
ISO Standard Size 07
Interface
This interface conforms to:
ISO 4401-07-07-0-05
ANSI/B93.7M (and NFPA)
size 07 CETOP R35H4.3-07
DIN 24340 Form A16
3/8 -16 UNC optional.
1/4 -20 UNC optional.
1/4” -20 UNC-2B optional.
15
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Mounting
Surfaces
Dimensions shown in mm (in).
ISO Standard Size 08
Interface
This interface conforms to:
ISO 4401-08-08-0-05
ANSI/B93.7M (and NFPA)
size 08 CETOP R35H4.3-08
DIN 24340 Form A25
1/2 -13 UNC optional.
2 holes Ø 7,5 (0.295 dia) x
8,0 (0.31) min. depth
6 holes, M12-6H x 20,0 (0.78)
min. full thread depth
153,0 (6.02) min.
5,6 (0.22)
17,5 (0.689)
29,4 ± 0,1 (1.157 ± 0.004)
53,2 ± 0,1 (2.094 ± 0.004)
94,5 ± 0,1 (3.720 ± 0.004)
100,8 (3.968)
112,7 (4.437)
130,2 ± 0,1 (5.126 ± 0.004)
77,0 (3.03)
92,1 ± 0,1
(3.626 ±
0.004)
74,6
(2.937)
73,0
(2.874)
46,0
(1.181)
19,0 (0.748)
17,5 (0.689)
118,0
(4.65) min.
4,8 ± 0,1
(0.189 ± 0.004)
Ports X,Y:
Ø 11,2 (0.44 dia) max.
Port L:
Ø 11,2 (0.44 dia) max.
Ports P, T, A, B:
Ø 25.0 (0.98 dia) max.
P
T
A
X
Y
L
B
34.9
[1.38]
41.3
[1.62]
76.2 [3.00]
82.6 [3.25]
114.3 [4.50]
138.6 [5.46]
147.6 [5.81]
168.3 [6.62]
190.5 [7.50]
230.1 [9.06]
44.4
[1.75]
79.4
[3.12]
123.8
[4.88]
130.2
[5.12]
158.8
[6.25]
198.9
[7.83]
7.1 Dia
[.28] Dia 3-Places
Ports X, Y, L
11.2 Dia
[.44] Dia 3-Places
Ports P, T, A, B
32.0 Dia (Max)
[1.26] Dia (Max)
T
P
Y
A
B
X
L
M20 Thread
[Optional .7500-10 UNC Thread]
ISO Standard Size 10
Interface
This interface conforms to:
ISO 4401-10-09-0-05
ANSI/B93.7M (and NFPA)
size 10, CETOP 35H4.3-10,
DIN 24340 Form A32
16
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Electrical
Information
WARNING
All power must be
switched off before
connecting or disconnecting
any plugs.
Of fset
Modulator
Valve envelope
7-pin plug connections
+24V
A
B
D
E
F
G
Power 0V
Enable or
not connected
Protective
ground
Non-inverting
Inverting
Command
signal
voltage,
see table
Compensation
network
+15V
0V
15V
+24V
LVDT
C
Monitor output
Gain
+24V
Solenoid
drive
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
Command Signals and Outputs, M1
7-pin plug Flow direction
Pin D Pin E
Positive OV
P to AOV Negative
U
D
- U
E
= Positive
Negative OV
P to BOV Positive
U
D
- U
E
= Negative
Block Diagram
Voltage Input (M1)
KBHDG5V Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
18 of this leaflet and Eatons
Installation Wiring Practices
for Vickers™ Electronic
Products, leaflet 2468.
Recommended cable sizes
are:
Power cables:
For 24V supply
0,75 mm
2
(18 AWG) up to
20m (65 ft)
1,00 mm
2
(16 AWG) up to
40m (130 ft)
Signal cables:
0,50 mm
2
(20 AWG)
Screen (shield):
A suitable cable would have
7 cores, a separate screen
for the signal wires and an
overall screen.
Cable outside diameter
8,0–10,5 mm (0.31–0.41
inches)
See connection diagram on
next page.
KBHDG5V Wiring
Wiring details for these
valves are contained in the
appropriate Eurocard
literature and the Installation
Wiring Practices for Vickers
Electronic Products leaflet
2468.
17
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Electrical
Information
KBHDG5V Wiring
Connections must be made
via the 7-pin plug mounted
on the amplifier. See page
19 of this leaflet and Eatons
Installation Wiring Practices
for Vickers™ Electronic
Products, leaflet 2468.
Recommended cable sizes
are:
Power cables:
For 24V supply
0,75 mm
2
(18 AWG) up to
20m (65 ft)
1,00 mm
2
(16 AWG) up to
40m (130 ft)
Signal cables:
0,50 mm
2
(20 AWG)
Screen (shield):
A suitable cable would have
7 cores, a separate screen
for the signal wires and an
overall screen.
Cable outside diameter
8,0–10,5 mm (0.31–0.41
inches)
See connection diagram on
next page.
KBHDG5V Wiring
Wiring details for these
valves are contained in the
appropriate Eurocard
literature and Eatons
Installation Wiring Practices
for Vickers™ Electronic
Products leaflet 2468.
WARNING
All power must be
switched off before
connecting/disconnecting
any plugs.
Offset
Modulator
Valve envelope
7-pin plug connections
+24V
A
B
D
E
F
G
Power 0V
Enable or
not connected
Protective ground
Command +4 to 20 mA
Compensation
network
+15V
0V
-15V
+24V
LVDT
C
Monitor output
+24V
Solenoid
drive
Gain
F1
R1
F2
Return
Pin C is used for a valve enable signal with electrical connections PH7 and PR7.
R1 shunt resistor 100R
F1, F2 resettable fuse
Command Signals and Outputs, M2
7-pin plug
Pin D Pin E Pin B Flow direction
More than Current Power
12 mA return ground P to A
Less than Current Power
12 mA return ground P to B
Block Diagram
Current Input (M2)
KBHDG5V
18
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Electrical
Information
Input
User Panel
Power
Supply
Demand
Signal
Spool
Position
Monitor
0V must be
connected to ground
Enclosure
+24V
0V
±10V
Connector
shell
Outer Screen
KB..PC7/PE7 valve
A
B
D or E
0V
0V
C
Drain Wire
Inner Screen
G
F
Valve
must be
connected
to ground
via
subplate
Wiring Connections
Voltage Input (M1)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground pin C.
0V
Input
User Panel
Power
Supply
Demand
Signal
Spool
Position
Monitor
+24V
±10V
Connector
shell
Outer Screen
A
B
D or E
0V
0V
C
Drain Wire
Inner Screen
E or D
G
F
KB..PR7/PH7 valve
Enable
Signal
+8.5V
to 36V
0V
Enclosure
Valve
must be
connected
to ground
via
subplate
0V must be
connected to ground
Wiring Connections for M1
Valves with Enable Feature
Note: In applications
where the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7 pin connector,
and the valve body must be
fastened to the earth ground.
Proper earth grounding
practices must be observed
in this case, as any
differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
19
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Electrical
Information
Input
User Panel
Power
Supply
Demand
Signal
Spool
Position
Monitor
0V must be
connected to ground
Enclosure
+24V
4 - 20 mA
0V
Valve
must be
connected
to ground
via
subplate
Connector
shell
Outer Screen
KB..PC7/PE7 valve
A
B
E
0V
0V
C
Drain Wire
Inner Screen
G
F
D
Wiring Connections
Current Input (M2)
Spool position monitor
voltage (pin F) will be
referenced to the KB valve
local ground.
WARNING
Do not ground pin C.
0V
Input
User Panel
Power
Supply
Demand
Signal
Spool
Position
Monitor
+24V
Connector
shell
4 - 20 mA
Outer Screen
A
B
E
0V
0V
C
Drain Wire
Inner Screen
D
G
F
KB..PR7/PH7 valve
0V must be
connected to ground
Enable
Signal
+8.5V
to 36V
0V
Enclosure
Valve
must be
connected
to ground
via
subplate
Wiring Connections for M2
Valves with Enable Feature
Note: In applications
where the valve must
conform to European
RFI/EMC regulations, the
outer screen (shield) must
be connected to the outer
shell of the 7 pin connector,
and the valve body must be
fastened to the earth ground.
Proper earth grounding
practices must be observed
in this case, as any
differences in command
source and valve ground
potentials will result in a
screen (shield) ground loop.
WARNING
Electromagnetic
Compatibility (EMC)
It is necessary to ensure that
the valve is wired up as
above. For effective
protection the user electrical
cabinet, the valve subplate or
manifold and the cable
screens should be
connected to efficient
ground points. The metal 7
pin connector part no.
934939 should be used for
the integral amplifier.
In all cases both valve and
cable should be kept as far
away as possible from any
sources of electromagnetic
radiation such as cables
carrying heavy current, relays
and certain kinds of portable
radio transmitters, etc.
Difficult environments could
mean that extra screening
may be necessary to avoid
the interference.
It is important to connect the
0V lines as shown above.
The multi-core cable should
have at least two screens to
separate the demand signal
and monitor output from the
power lines.
The enable line to pin C
should be outside the screen
which contains the demand
signal cables.
20
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Application
Data
Fluid Cleanliness
Proper fluid condition is
essential for long and satis-
factory life of hydraulic com-
ponents and systems.
Hydraulic fluid must have the
correct balance of cleanli-
ness, materials and additives
for protection against wear
of components, elevated vis-
cosity and inclusion of air.
Recommendations on con-
tamination control methods
and the selection of products
to control fluid condition are
included in Vickers publica-
tion 9132 or 561, “Vickers
Guide to Systemic
Contamination Control”. The
book also includes informa-
tion on the Vickers concept
of “ProActive Maintenance.
The following recommenda-
tions are based on ISO
cleanliness levels at 2 µm,
5 µm and 15 µm
For products in this catalog
the recommended levels are:
0 to 70 bar (1000 psi) –
18/16/13
70 + bar (1000 + psi) –
17/15/12
Vickers products, as any
components, will operate
with apparent satisfaction in
fluids with higher cleanliness
codes than those described.
Other manufacturers will
often recommend levels
above those specified.
Experience has shown,
however, that life of any
hydraulic components is
shortened in fluids with
higher cleanliness codes
than those listed above.
These codes have been
proven to provide a long
trouble-free service life for
the products shown, regard-
less of the manufacturer.
Hydraulic Fluids
Materials and seals used in
these valves are compatible
with antiwear hydraulic oils,
and non-alkyl-based phos-
phate esters. The extreme
operating viscosity range is
500 to 13 cSt (2270 to 70
SUS) but the recommended
running range is 54 to 13 cSt
(245 to 70 SUS). For further
technical information about
fluids see “Technical
Information” leaflet B-920
or I-286S.
Installation
The proportional valves in
this catalog can be mounted
in any attitude, but it may be
necessary in certain demand-
ing applications, to ensure
that the solenoids are kept
full of hydraulic fluid. Good
installation practice dictates
that the tank port and any
drain port are piped so as to
keep the valves full of fluid
once the system start-up has
been completed.
Extension Cable
Extension Cable: Adapter for
extending 7 core cable when
changing from KA to KB
valve and existing wiring is
not long enough. Consists of
a 7 pin plug, a 7 pin socket
and a length of cable, fully
assembled for ease of use
Extension Cable 944450
Service Information
The products from this range
are preset at the factory for
optimum performance; disas-
sembling critical items would
destroy these settings. It is
therefore recommended that
should any mechanical or
electronic repair be neces-
sary they should be returned
to the nearest Vickers repair
center. The products will be
refurbished as necessary and
retested to specification
before return.
Field repair is restricted to
the replacement of the
seals.
Note: The feedback/solenoid
assembly installed in this
valve should not be disas-
sembled.
PILOT WITH REDUCER
metric inch
BK464125M BK870017
PILOT WITHOUT REDUCER
metric inch
BK616452M BK590716
KBHDG5V-5 MAINSTAGE
metric inch
BKDG01633M BKDG01633
KBHDG5V-7 MAINSTAGE
metric inch
BKDG7858918 BKD590724
KBHDG5V-8 MAINSTAGE
metric inch
BKDG8-655M BKDG06-635
KBHDG5V-10 MAINSTAGE
metric inch
BKDG10636M BKDG10636
If not using Vickers recommended bolt kits,
bolts used should be to ISO898, 12.9 or better.
Mounting Bolt Kits Seal Kits
PILOT VALVE
02-332693
REDUCER
859316
KBHDG5V-5
Complete valve 02-3505018
KBHDG5V-7
Complete valve 02-3505019
KBHDG5V-8
Complete valve 02-350686
KBHDG5V-10
Complete valve 02-411687
Electrical Connection
7-PIN CONNECTOR
metric plastic
934939 694534
(Metal connector must be used for full
EMC protection)
Note: An alternative metal
connector which gives EMC
protection but not IP67
rating is available from
ITT-Cannon, part number
CA06-COM-E-14-A7-S.
21
EATON Vickers KBHDG5V Proportional Two-Stage Directional Valves V-VLDI-MC001-E2 February 2008
Released
Model Codes
5996502-001 KBHDG5V-5-2C90N60-E-X-M1-PE7-H4-11
5996507-001 KBHDG5V-5-2C90N60-E-X-M2-PE7-H4-11
5996485-001 KBHDG5V-5-2C95N-E-M1-PC7-H4-11
5996486-001 KBHDG5V-5-2C95N-E-M1-PE7-H4-11
5996504-001 KBHDG5V-5-2C95N-E-M2-PE7-H4-11
5996487-001 KBHDG5V-5-2C95N-E-X-M1-PE7-H4-11
5996505-001 KBHDG5V-5-2C95N-E-X-M2-PC7-H4-11
5996508-001 KBHDG5V-5-2C95N-E-X-M4-PE7-H4-11
5996488-001 KBHDG5V-5-2C95N-M1-PC7-H4-11
5996484-001 KBHDG5V-5-2C95N-T-M1-PE7-H4-11
5996491-001 KBHDG5V-5-2C95N-T-X-M1-PE7-H4-11
5996489-001 KBHDG5V-5-2C95N-X-M1-PC7-H4-11
5996490-001 KBHDG5V-5-2C95N-X-M1-PE7-H4-11
5996499-001 KBHDG5V-5-33C60N40-X-M1-PE7-H4-11
02-412501 KBHDG5V-5-33C80N-E-M2-PE7-H4-11
5996493-001 KBHDG5V-5-33C80N-E-X-M1-PC7-H4-11
5996494-001 KBHDG5V-5-33C80N-E-X-M1-PE7-H4-11
5996501-001 KBHDG5V-5-33C80N-T-X-M1-PE7-H4-11
5996500-001 KBHDG5V-5-33C80N-X-M1-PE7-H4-11
5996492-001 KBHDG5V-5-33C80N-X-M1-PH7-H4-11
5996506-001 KBHDG5V-5-33C80N-X-M2-PH7-H4-11
5996497-001 KBHDG5V-5-5C85N-E-X-M1-PC7-H4-11
5996495-001 KBHDG5V-5-5C85N-E-X-M1-PE7-H4-11
5996498-001 KBHDG5V-5-5C85N-T-X-M1-PE7-H4-11
5996496-001 KBHDG5V-5-5C85N-X-M1-PE7-H4-11
5996503-001 KBHDG5V-5-PQ87F-E-X-M1-PE7-H4-11
Size D07/NG16
ASSEMBLY
NUMBER MODEL CODE
5996588-001 KBHDG5V-7-133C150N80N20-E-X-M1-PE7-H4-11
5996603-001 KBHDG5V-7-2C150N85-E-X-M1-PC7-H4-11
5996604-001 KBHDG5V-7-2C150N85-X-M1-PC7-H4-11
5996602-001 KBHDG5V-7-2C150N85-X-M1-PE7-H4-11
5996589-001 KBHDG5V-7-2C150N85-X-M1-PH7-H4-11
5996614-001 KBHDG5V-7-2C150N85-X-M2-PE7-H4-11
5996605-001 KBHDG5V-7-2C200N-E-X-M1-PE7-H4-11
5996590-001 KBHDG5V-7-2C200N-T-M1-PE7-H4-11
5996593-001 KBHDG5V-7-2C200N-T-X-M1-PE7-H4-11
5996591-001 KBHDG5V-7-2C200N-X-M1-PC7-H4-11
5996592-001 KBHDG5V-7-2C200N-X-M1-PE7-H4-11
5996611-001 KBHDG5V-7-2C200N-X-M2-PC7-H4-11
5996615-001 KBHDG5V-7-2C200N-X-M4-PC7-H4-11
5996606-001 KBHDG5V-7-33C130N65-X-M1-PE7-H4-11
5996595-001 KBHDG5V-7-33C160N-E-M1-PC7-H4-11
5996607-001 KBHDG5V-7-33C160N-E-M1-PE7-H4-11
5996601-001 KBHDG5V-7-33C160N-E-X-M1-PC7-H4-11
5996594-001 KBHDG5V-7-33C160N-T-X-M1-PE7-H4-11
5996596-001 KBHDG5V-7-33C160N-X-M1-PC7-H4-11
5996597-001 KBHDG5V-7-33C160N-X-M1-PE7-H4-11
5996612-001 KBHDG5V-7-33C160N-X-M2-PE7-H4-11
02-412331 KBHDG5V-7-33C160N-X-T-M2-PE7-H4-11
5994273-001 KBHDG5V-7-5C200N115-M1-PE7-H4-11
5996608-001 KBHDG5V-7-5C200N-E-M1-PE7-H4-11
5996609-001 KBHDG5V-7-5C200N-E-X-M1-PE7-H4-11
5996613-001 KBHDG5V-7-5C200N-E-X-M2-PE7-H4-11
5996598-001 KBHDG5V-7-5C200N-M1-PE7-H4-11
5996599-001 KBHDG5V-7-5C200N-T-M1-PE7-H4-11
5996600-001 KBHDG5V-7-5C200N-X-M1-PE7-H4-11
5996610-001 KBHDG5V-7-PQ190F-E-X-M1-PE7-H4-11
Size D08/NG25
ASSEMBLY
NUMBER MODEL CODE
5996650-001 KBHDG5V-8-2C375N250-X-M1-PE7-H4-11
5996647-001 KBHDG5V-8-2C375N-E-X-M1-PE7-H4-11
5996656-001 KBHDG5V-8-2C375N-E-X-M2-PE7-H4-11
5996658-001 KBHDG5V-8-2C375N-E-X-M4-PE7-H4-11
5996648-001 KBHDG5V-8-2C375N-X-M1-PC7-H4-11
5996649-001 KBHDG5V-8-2C375N-X-M1-PE7-H4-11
5996651-001 KBHDG5V-8-33C375N-E-X-M1-PE7-H4-11
5996657-001 KBHDG5V-8-33C375N-E-X-M2-PE7-H4-11
5996652-001 KBHDG5V-8-33C375N-X-M1-PE7-H4-11
5996654-001 KBHDG5V-8-5C375N-E-X-M1-PC7-H4-11
5996653-001 KBHDG5V-8-72C375N250-E-X-M1-PH7-H4-11
5996655-001 KBHDG5V-8-PQ375F-E-M1-PC7-H4-11
02-412742 KBHDG5V-8-PQ375F-E-X-M1-PE7-H4-11
Size D10/NG32
ASSEMBLY
NUMBER MODEL CODE
5996664-001 KBHDG5V-10-12C700N420-E-X-M1-PE7-H4-11
5996665-001 KBHDG5V-10-133C700N420-E-X-M1-PE7-H4-11
5996672-001 KBHDG5V-10-2C700N420-E-M1-PE7-H4-11
5996661-001 KBHDG5V-10-2C700N420-E-X-M1-PE7-H4-11
5996670-001 KBHDG5V-10-2C700N-E-M1-PE7-H4-11
5996659-001 KBHDG5V-10-2C700N-E-X-M1-PE7-H4-11
5996674-001 KBHDG5V-10-2C700N-E-X-M1-PR7-H4-11
5996678-001 KBHDG5V-10-2C700N-E-X-M2-PE7-H4-11
5996681-001 KBHDG5V-10-2C700N-E-X-M4-PE7-H4-11
5996676-001 KBHDG5V-10-2C700N-X-M1-PE7-H4-11
5996673-001 KBHDG5V-10-33C700N420-E-M1-PE7-H4-11
5996662-001 KBHDG5V-10-33C700N420-E-X-M1-PE7-H4-11
5996671-001 KBHDG5V-10-33C700N-E-M1-PE7-H4-11
5996660-001 KBHDG5V-10-33C700N-E-X-M1-PE7-H4-11
5996675-001 KBHDG5V-10-33C700N-E-X-M1-PR7-H4-11
5996679-001 KBHDG5V-10-33C700N-E-X-M2-PE7-H4-11
5996677-001 KBHDG5V-10-33C700N-X-M1-PE7-H4-11
5996663-001 KBHDG5V-10-5C720N-E-X-M1-PE7-H4-11
5996680-001 KBHDG5V-10-5C720N-E-X-M2-PE7-H4-11
5996666-001 KBHDG5V-10-72C700N420-E-X-M1-PE7-H4-11
5996667-001 KBHDG5V-10-733C700N420-E-X-M1-PE7-H4-11
5996668-001 KBHDG5V-10-PQ680F-E-X-M1-PE7-H4-11
ASSEMBLY
NUMBER MODEL CODE
ASSEMBLY
NUMBER MODEL CODE
Size D05/NG10
© 2008 Eaton Corporation
All Rights Reserved
Printed in USA
Document No. V-VLDI-MC001-E2
Supersedes V-VLDI-MC001-E
February 2008
Eaton
Hydraulics Operations USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.hydraulics.eaton.com
Eaton
Hydraulics Operations Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601
Eaton
Hydraulics Operations Asia Pacific
11th Floor Hong Kong New World Tower
300 Huaihai Zhong Road
Shanghai 200021
China
Tel: 86-21-6387-9988
Fax: 86-21-6335-3912