EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 E-141.A
An Eaton Brand
E
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
RV5-10 - Relief Valve
Spool, pilot operated
114 L/min (30 USgpm) • 350 bar (5000 psi)
53,0
(2.08)
Ø 15,82 (0.623)
“I” Adjustm ent
2
1
0.875"-14 Thd.
“S”Adjustm ent
31,8
(1.25)
80,0
(3.13)
25,4 (1.00) hex
“C”Adjustm ent
19,1 (0.75) hex
“K”Adjustm ent
Ø 38,1 (1.50)
“F”Adjustm ent
Model Code
RV5 (A) 10 (V)
*
(S)
** **
/
**
00
1 2 3 4 5 6 7 8 9 10
1
Function
RV5
2
Cage seals
BlankA
3
Size
10
4
Seal Material
BlankV
5
Adjustment
C F I K S
6
Valve Housing Material
BlankS
7
Port Size
Code Port Size Housing Number
Aluminum Aluminum Steel
Light duty Fatigue rated Fatigue rated
0 Cartridge only
3B 3/8" BSPP 02–175462 – –
2G 1/4" BSPP – 876702 02–175102
3G 3/8" BSPP – 876703 02–175103
6H SAE 6 – 876700 –
8H SAE 8 – 876701 –
6T SAE 6 566151 – 02–175100
8T SAE 8 – – 02–175101
H10H SAE 10* – 4997062-001 –
2K10H SAE 10** – 4997060-001 –
* Bolt on, dual cross over relief valve package for Eaton H or T series motors
** Bolt on, dual cross over relief valve package for Eaton 2000 series motors
(Note: Two cartridges are installed in this special housing, both are set to the same
crack pressure specified in model Code position 9, maximum allowed setting is 210
bar (3000 psi), only available with RV5A option and aluminum housing.)
See section J for housing details.
8
Cracking Pressure Range
Note: Code based on pressure
in psi.
3 - 3,4-20 bar (50-300 psi)
20 - 7-140 bar (100-2000 psi)
35 - 17-240 bar (250-3500 psi)
50 - 35-350 bar (500-5000 psi)
9
Setting pressure
Within ranges in
8
Blank - Normal factory setting
at approximate mid-range.
User requested settings in
3,45 bar (50 psi) steps, Coded
as in the following examples:
10 - 70 bar (1000 psi)
10.5 - 72,4 bar (1050 psi)
10
Special features
00 - None
(Only required if valve has special
features, omitted if "00.")
SS - 316 Stainless Steel
external components
•
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
Dimensions
mm (inch)
Torque cartridge in housing
A - 47-54 Nm (35-40 ft. lbs)
S - 68-75 Nm (50-55 ft. lbs)
Installation Drawing (Steel)Cartridge Only
– – – – – –
63.5
(2.50)
2X 7.1
(0.28)
9.5
(0.37)
12.7
(0.5)
63.5
(2.50)
19.1
(0.175)
22.2
(0.87)
1
2
80.0
(3.13)