EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 F-410.A
An Eaton Brand
F
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Operation
The check section allows
free flow into the actuator
then holds and locks the load
against movement. The pilot
assisted relief valve section
will give controlled movement
when pilot pressure is applied.
The relief section is normally
set to open at a pressure at
least 1.3 times the maximum
load induced pressure but the
pressure required to open the
valve and allow movement
Pressure Drop
Description
The 1SER series overcenter
valve performs all duties of
a regular overcenter but is
able to relieve and stay open
irrespective of downstream
pressure. This enables the
valve to operate when
used with a closed center
directional valve which has
service line reliefs. The
poppet is pressure balanced,
preventing relief setting
increase due to back pressure.
Ratings and Specifications
Figures based on: Oil Temp = 40˚C Viscosity = 32 cSt (150 SUS)
Rated flow 90 L/min (23 USgpm)
Max relief setting 350 bar (5000 psi)
Max load induced pressure: 270 bar (4000 psi)
Cartridge material Working parts hardened and ground steel.
External steel surfaces zinc plated.
Mounting position Unrestricted
Cavity number A20092-T2A
Torque cartridge into cavity 60 Nm (44 lbs ft)
Weight 0.42 kg (0.92 lbs)
Seal kit number SK1093 (Nitrile) SK1093V (Viton
®
)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating temperature -30° to +90°C (-22° to +194°F)
Leakage 0.3 milliliters/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt
Viton is a registered trademark of E.I. DuPont
Performance Data
Sectional View
depends on the pilot ratio of
the valve. For optimization
of load control and energy
usage, a choice of pilot ratios
is available.
The pressure required to open
the valve and start actuator
movement can be calculated
as follows:
Pilot Pressure =
(Relief Setting) - (Load Pressure)
Pilot Ratio
Features
Cartridge is economical and
fits simple cavity. Allows quick,
easy field service - reduces
down time. Interchangeable
with pilot check valve of a
similar size.
Pilot Ratio
4:1 Best suited for applications
where the load remains
relatively constant.
Other ratios available on request.
1SER90 - Overcenter Valve
Part balanced, pilot assisted relief with check
90 L/min (23 USgpm) • 270 bar (4000 psi)
Pilot (3)
Valve (2)
Cyl (1)
Flow - US gpm
Flow - L/min
Pressure - psi
Pressure - bar
240
210
180
150
120
90
60
30
0
16
14
12
10
8
6
4
2
0
0 20 40 60 80 100
0 5 10 15 20 25
Piloted open
Free ow
3
1
2