EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-360.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
NV1-16 - Flow Restrictor Valve
Needle
151 L/min (40 USgpm) • 210 bar (3000 psi)
Operation
This needle valve is non-
pressure compensated. Flow is
controlled in the direction from
port 2 to port 1, from full flow
to tight shut-off, by turning the
adjustment feature clockwise.
The flow from port 1 to port 2
will be restricted.
Pressure Drop Curves
Cartridge only
Features
Hardened and ground working
components. Cartridge
construction for maximum
mounting flexibility.
Pressure drop - psi
Pressure drop - bar
Flow - L/min (21,8 cSt oil @ 49°C)
70
60
50
40
30
20
10
0
5
4
3
2
1
0 20 40 60 80 100 120 140
0 10 20 30 40
Flow - USgpm (105 SUS oil @ 20°F)
Description
This is a manually adjusted
cartridge type needle valve. With
fine control it is ideal for none
compensated speed control of
actuators or as a control orifice
in conjunction with a pressure
compensator Total shut off can
be achieved allowing the valve
to be used as a shut of valve.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 151 L/min (40 USgpm)
Internal leakage 5 drops/min maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration
Cleanliness code 18/16/13
Standard housing material Aluminum
Weight cartridge only 0,34 kg. (0.76 lbs)
Seal kit 565810 (Buna-N), 889609 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance DataSectional View
Full open port 2 to port 1
1
2
2
1