EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-300.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
PFRD/S-16 - Priority Flow Control
Spool Type, Load-Sensing
150 L/min (40 USgpm) 280 bar (4000 psi)
Operation
This valve is used in the flow
control mode. Pump flow
from the valve inlet port 3
is delivered first to port 4
at a fixed rate; excess flow
is bypassed to port 2. The
valve maintains the controlled
flow to 4 regardless of inlet
pressure change or load
pressure changes at 2 or 4.
This valve is typically used
with open loop load sense
systems in steering and
braking circuits. The static
type is used for less difficult
applications where response
or circuit stability is not a
problem. The dynamic type is
used for difficult applications
where response or circuit
Pressure Drop
Cartridge only
stability are critical. The load
sense line connected to
port 5 should not exceed 2
Meters (6 Feet) in length.
Overpressure protection for
the circuits connected to ports
2 and 4 must be provided
by external relief valves. The
control pressure is determined
by assuring adequate inlet
pressure to the steering unit
and must be matched to the
steering units required flow.
The control pressure must
be supplied to the valve as a
minimum inlet pressure. The
pressure at port 4 can vary
by 10% when the load at the
excess flow port 2 varies from
0 to maximum pressure.
0
50
100
150
200
250
0 5 10 15 20 25 30 35 40 45
38 75 114 151
3
7
10
14
Flow - USgpm
P to EF
Pressure drop psi
Flow - L/min
Pressure drop bar
Description
This is a load sense priority
flow regulator designed to
provide a controlled pressure
compensated flow on
demand. The valve is ideal
for steering or accumulator
charging circuits.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 280 bar (4000 psi)
Cartridge fatigue pressure (infinite life) 280 bar (4000 psi)
Rated inlet flow 150 L/min (40 USgpm)
Temperature range -40° to 120°C (-40° to 248°F))
Cavity C–16–5S
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration
Cleanliness code 18/16/13
Standard housing material Aluminum or Steel
Weight cartridge only 0,47 kg (1.05 lbs)
Seal kit 202915-922
Internal leakage 164cc/min (10 in 3/min) @ 3000 PSID
Recommended L/S orifice 0.036" (not included in valve)
Performance Data
Note: Minimum inlet flow
should not be less than 1/4
of maximum inlet flow.
Minimum pressure drop
is determined by control
pressure.
Note
Port 1 unused, port should be
plugged.
Sectional View
Features
Hardened and ground working
parts to limit leakage and
extend service life. Robust
design with a 280 bar max
pressure rating.
Dynamic Signal (PFRD)
Static Signal (PFRS)
2
5 (LS)
4 (CF)
2 (EF)
1
3 (P)
2
5 (LS)
4 (CF)
2 (EF)
1
3 (P)
1
2
3
4
5
(LS)
(CF)
(P)
(EF)
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-301.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
PFRD/S-16 - Priority Flow Control
Spool Type, Load-Sensing
150 L/min (40 USgpm) 280 bar (4000 psi)
17.8 (.70)
96.3 (3.79)
1.50" HEX
1 5/16"-2 UN-2A
1
2
3
4
5
LS
CF
P
EF
1
Function
PFRS - Priority flow regulator
Static signal type
PFRD - Priority ow regulator
Dynamic signal type
2
Size
16 - 16 size
3
Seal Material
U - Urethane (standard)
Model Code
2 31
PFR*
16
U
5
***
6
***
4
*
7
00
6
Control Pressure
PFRS options
065 - 65 psi (4.5 bar)
130 - 130 psi (8.9 bar)
100 - 100 psi (11.0 bar)
PFRD options
080 - 80 psi (5.5 bar)
110 - 110 psi (7.6 bar)
130 - 130 psi (9.0 bar)
7
Special Features
00 - None
(Only required if valve has special
features, omit if ("00")
5
Port Size
Code Port Size Housing Number
Port 2, 3, 4 Port 5 Aluminium Steel
000 No Body
12T SAE 12 SAE 4 4994880-001 4994881-001
16T SAE 16 SAE 4 4994880-002 4994881-002
06G 3/4" BSPP 1/4" BSPP 4994880-003 4994881-003
08G 1" BSPP 1/4" BSPP 4994880-004 4994881-004
*These model digits will not be stamped on the valve.
See section J for housing details.
4
Valve Housing Material
O - Cartridge only
A - Aluminum
S - Steel (standard)
Dimensions
mm (inch)
Cartridge Only
Basic Code
PFRD/S-16
Torque cartridge in housing
A - 108-122 Nm (80-90 ft lbs)
B - 136-149 Nm (100-110 ft lbs)
Note: Standard housings
include port 1, however for
most applications this port
must be blocked.
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
Installation Drawing (Steel)
62.74
(2.470)
31.4
(1.23)
85.7
(3.38)
36.1
(1.42)
114.3
(4.50)
126.2
(4.97)
113.5
(4.47)
95.25
(3.750)
9.5
(0.37)
17.8
(0.70)
2 x 08.74
(0.344)
31.4
(1.23)
58.7
(2.31)
16.9
(0.66)
4
2
1
5
3