Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
VF1-10/VF11-10 - Velocity Fuse
23 L/min (6 USgpm) • Up to 350 bar (5000 psi)
Operation
This valve is normally open
from port 1 to port 2. When
flow exceeds the setting of
the valve, it closes. The valve
returns to the open condition
when the pressure at port 1 is
reduced to less than 80 psi.
Features
Hardened and ground and
honed working components.
Cartridge construction for
maximum mounting flexibility.
Description
This is a screw in cartridge
velocity fuse used to lock a
cylinder or motor in place in
the case of a complete hose
failure.
Sectional View
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) VF1/VF11 210 bar (3000 psi) / 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) VF1/VF11 210 bar (3000 psi) / 350 bar (5000 psi)
Rated Flow 23 L/min (6 USgpm)
Flow regulation accuracy 1,9–22,7 L/min (0.5–6.0 USgpm) ±20%
Factory set maximum flow rate accuracy under
standard test conditions and within the above ranges
Internal leakage Port 2 to 1; <5 drops/min, maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–10–2
Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20, etc
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminium or steel
Weight 0,11 kg (0.25 lbs)
Seal kit 565803 (Buna-N)
566086 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
A - 22,8 L/min (6 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
B - 14,44 L/min (3 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
C - 3,8 L/min (1 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
30
25
20
15
10
5
0 7 10 14 17 20
0 45 100 150 200 250
8
6
4
2
0
Pressure drop - psi
Pressure drop - bar
A
B
C
300
3
Flow - L/min
(21,8 cSt oil @ 49°C)
Flow - USgpm
(105 SUS oil @ 120°F)
Pressure Drop
Cartridge only
Note: The valve is not intended
for use in pump unloading
applications
2
1
Fusing direction
Reverse
flow direction
2
1
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-571.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
VF1-10/VF11-10 - Velocity Fuse
23 L/min (6 USgpm) • Up to 350 bar (5000 psi)
Model Code
1
Function
VF1 - Velocity fuse 210 bar
(3000 psi)
VF11 - Velocity fuse 350 bar
(5000 psi)
2
Size
10 - Size
3
Seals
N or Blank - Buna-N
V - Viton
®
4
Adjustment
F - Fixed orice
2 3 4 51
VF(*)1 10 (V) F **
Code Port Size Housing Number
Aluminium Aluminium Steel
Light Duty Fatigue Rated
0 Cartridge only
(A)3B 3/8" BSPP 02–175462
(A)6T SAE 6 566151
(A)2G 1/4" BSPP 876702
(A)3G 3/8" BSPP 876703
(A)6H SAE 6 876700
(A)8H SAE 8 876701
S6T SAE 6 02-175100
S8T SAE 8 02-175101
S2G 1/4” BSPP 02-175102
S3G 3/8” BSPP 02-175103
See section J for housing details.
5
Port Size
6
Factory Set Flow Rate
(Specify in USgpm) Range
1,9-22,7 L/min ((0.5 - 6.0 USgpm)
7
Special Features
00 - None
(Only required if valve has special
features, omitted if "00".)
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
6
*.*
7
00
Dimensions
mm (inch)
Cartridge Only
Basic Code
VF1/11
Torque cartridge in housing:
A - 47-54 Nm (35-40 ft lbs)
S - 68-75 Nm (50-55 ft lbs)
19,0
(0.75)
ø15,82 (0.623)
0.875"-14 Thd.
25,4 (1.00) hex
31,7
(1.25)
2
1
2
1
0.81
(20.7)
1.25
(31.7)
0.875"-14 Thd.
.62 (15.8)
Installation Drawing (Steel)
63.5
(2.50)
50.8
(2.00)
28.6
(1.13)
76.2
(3.00)
22.2
(0.87)
95
(0.37)
44.45
(1.75)
2 X Ø7.14
(0.281)
44.45
(1.75)
19