EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-580.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
VF1-16 - Velocity Fuse
114 L/min (30 USgpm) • 210 bar (3000 psi)
Description
This is a screw in cartridge
velocity fuse used to lock a
cylinder or motor in place in
the case of a complete hose
failure.
Operation
This valve is normally open
from port 1 to port 2. When
flow exceeds the setting of
the valve, it closes. The valve
returns to the open condition
when the pressure at port 1 is
reduced to less than 80 psi.
Features
Hardened and ground and
honed working components.
Cartridge construction for max-
imum mounting flexibility.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 114 L/min (30 USgpm)
Flow regulation accuracy 9,5–114 L/min (2.5–30.0 USgpm) ±20%
Factory set maximum flow rate accuracy under
standard test conditions and within the above ranges
Internal leakage Port 1 to 2 closed; <5 drops/min
maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,33 kg (0.72 lbs)
Seal kit 565810 (Buna-N) 889609 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
Sectional View
Pressure Drop
Cartridge only
150
125
100
75
50
25
0 7 10 14 17 20
0 45 100 150 200 250
40
30
20
10
0
Pressure drop - psi
Pressure drop - bar
A
B
C
300
3
Flow - L/min
(21,8 cSt oil @ 49°C)
Flow - USgpm
(105 SUS oil @ 120°F)
A - 114 L/min (30 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
B - 60 L/min (15 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
C - 19 L/min (5 USgpm)
maximum flow setting
Port 1 to 2,
fusing direction
Port 2 to 1, reverse
flow down to 0
Note: The valve is not
intended for use in pump
unloading applications.
2
1
Fusing direction
Reverse
flow direction
2
1