EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-490.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 38 L/min (10 USgpm)
Cavity C-10-4
Standard housing materials Customized housings are necessary for close-coupling,
the compensator and orifice
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,14 kg (0.32 lbs)
Seal kit 889651 (Buna-N)
889653 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
PCS14-10 - Pressure Compensator
Bypass or priority
38 L/min (10 USgpm) 350 bar (5000 psi)
Description
This is a high pressure priority
style compensator suitable for
use with a separate needle
valve or orifice to provide a
priority pressure compensated
flow. This when used in a
manifold is ideal for motor or
cylinder control where priority
is required.
Performance Data
Performance Characteristics
Cartridge only
Operation
This valve, when used with
either a fixed or variable orifice
on port 4, maintains a constant
flow out of port 3, regardless of
pressure changes downstream
of port 3. This is based on
whatever pressure differential is
chosen. All flow in excess of the
priority requirement is bypassed
from port 1 to port 2. If the
priority port is deadheaded, the
valve will try to direct flow out
of the priority port and shut off
the bypass flow, blocking of all
flow.
Features
Hardened and ground and
honed working components.
Cartridge construction for
maximum mounting flexibility.
Working pressure 350 bar.
Sectional View
A - 2,8 bar (40 psi) (control P)
B - 5,5 bar (80 psi) (control P)
C - 11,0 bar (160 psi) (control P)
0 1 2 3 4 5 6 7 8 9 10
0 4 8 12 16 20 24 28 32 36
Controlled flow - L/min (21,8 cSt oil @ 49C)
Controlled flow - USgpm (105 SUS oil @ 120°F)
1
2
3
4
5
0
0.025
0.050
0.075
0.100
0.125
0
0.150
0.175
0.200
A
B
C
Approx. orifice diameter - inches
Approx. orifice diameter - mm
2
1
3
4
4
2
1
3
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-491.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
PCS14-10 - Pressure Compensator
Bypass or priority
38 L/min (10 USgpm) 350 bar (5000 psi)
Torque into aluminum housing
to 47-54 Nm (35-40 ft. lbs)
Torque into steel housing to
68-75 Nm (50-55 ft. lbs)
Model Code
1 Function
PCS14 - Pressure compensator
bypass type
2 Size
10 - 10 Size
3 Seals
Blank - Buna-N
V - Viton
®
PCS14 10 (V) * *** 00
1 2 3 4 5 6
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
5 Pressure Dierential
(Nominal)
40 - 2,8 bar (40 psi)
80 - 5,5 bar (80 psi)
160 - 11,0 bar (160 psi)
6 Special Features
00 - None
(Only required if valve has special
features, omitted if “00.”)
4 Port Size
0 - Cartridge only
(Customized housings are necessary
for close-coupling, compensator
and orice)
Dimensions
mm (inch)
Cartridge Only
Basic Code
PCS14-10
4
25,65
(1.010)
25.4"
(1.0) hex
15.78 - 15.82 (0.621 - 0.623)
17.38 - 17.42 (0.684 - 0.686)
18.95 - 18.99 (0.746 - 0.748)
7/8" - 14 Unf - 2A Thd.
62,0
(2.44)
3
2
1