EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-500.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F)
Typical application pressure (all ports) 240 bar (3500 psi)
Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
Rated flow 58 L/min (15 USgpm)
Cavity C-12-4
Standard housing materials Customized housings are
necessary for close-coupling,
the compensator and orifice
Temperature range -40° to 120° C (-40° to 248° F)
Fluids All general purpose hydraulics fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,36 kg (0.80 lbs)
Seal kit 9900335-000 (Buna-N)
9900336-000 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Operation
This valve, when used with
either a fixed or variable
orifice on port 4, maintains
a constant flow out of port
3, regardless of pressure
changes downstream of port
3. This is based on whatever
pressure differential is chosen.
All flow in excess of
the priority requirement is
bypassed from port 1 to
port 2. If the priority port is
deadheaded, the valve will
try to direct flow out of the
priority port and shut off the
bypass flow, blocking of all
flow.
Features
Hardened and ground and
honed working components.
Cartridge construction for
maximum mounting flexibility.
Performance Data
Sectional View
Description
This is a priority style
compensator suitable for use
with a separate needle valve
or orifice to provide a priority
pressure compensated flow.
This when used in a manifold
is ideal for motor or cylinder
control where priority is
required.
External orifice diameter (inch)
Flow (GPM)
A
B
C
0 5 10 15
0.300
0.350
0.250
0.200
0.150
0.100
0.050
0.000
Performance Characteristics
Cartridge only
A - 2,8 bar (40 psi) (control P)
B - 5,5 bar (80 psi) (control P)
C - 11,0 bar (160 psi) (control P)
PCS4-12 - Pressure Compensator
Bypass or priority
58 L/min (15 USgpm) 240 bar (3500 psi)
2
1
3
4
1
2
3
4
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-501.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
PCS4-12 - Pressure Compensator
Bypass or priority
58 L/min (15 USgpm) 240 bar (3500 psi)
1 Function
PCS4 - Pressure compensator
restrictive type
2 Size
12 - 12 size
Dimensions
mm (inch)
3 Seal Material
Blank - Buna-N
V - Viton
®
4 Port Size
0 - Cartridge only
(Customized housings are necessary
for close-coupling, compensator
and orifice)
Torque into aluminum housing
to 81-95 Nm (60-70 ft lbs)
Torque into steel housing to
102-115 Nm (75-85 ft lbs)
Model Code
PCS4 12 (V) * *** 00
1 2 3 4 5 6
6 Pressure Dierential
(Nominal)
40 - 2,8 bar (40 psi)
80 - 5,5 bar (80 psi)
120 - 8,3 bar (120 psi)
7 Special Features
00 - None
(Only required if valve has special
features, omit if "00".)
Cartridge Only
Basic Code
PCS4-12
33,3 (1.31)
20,6 (.810)
22,1 (.872)
23,7 (.935)
1 1/16 - 12 UNF - 2A THREAD
31,7 (1.25) HEX
90,2 (3.55)