EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-410.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
PCS3-10 - Pressure Compensator
Restrictive
38 L/min (10 USgpm) • 210 bar (3000 psi)
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 38 L/min (10 USgpm)
Cavity C-10-3
Standard housing materials Customized housings are
necessary for close-coupling,
the compensator and orifice
Temperature range -40° to 120° C (-40° to 248° F)
Fluids All general purpose hydraulics fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,12 kg (0.26 lbs)
Seal kit 565812 (Buna-N), 889611 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Operation
This valve, when used with
either a fixed or variable orifice
between port 1 and port 3,
maintains a constant flow.
This is based on what ever
pressure differential is chosen.
Flow out of port2, regardless
of pressure, changes
downstream on port2.
Features
Hardened and ground and
honed working components.
Cartridge construction for
maximum mounting flexibility.
Performance Characteristics
Cartridge only
Performance DataSectional View
Description
This is a restrictive style
compensator suitable for use
with a separate needle valve
or orifice to provide a pressure
compensated flow while
the excess oil passes over a
relief valve or closes down
the compensator on a pump.
This, when used in a manifold,
is ideal for motor or cylinder
speed control either meter in
or meter out.
Controlled flow - L/min (21,8 cSt oil @ 49°C)
Controlled flow - USgpm (105 SUS oil @ 120°F)
1
2
3
4
5
0
0.025
0.050
0.075
0.100
0.125
0
0 1 2 3 4 5 6 7 8 9 10
0 4 8 12 16 20 24 28 32 36
0.150
0.175
0.200
A
B
C
Approx. orifice diameter - inches
Approx. orifice diameter - mm
A - 2,8 bar (40 psi) (control P)
B - 5,5 bar (80 psi) (control P)
C - 11,0 bar (160 psi) (control P)
1
3
1
2