EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-370.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
NV1-20 - Flow Restrictor Valve
Needle
265 L/min (70 USgpm) • 210 bar (3000 psi)
Operation
This needle valve is non-
pressure compensated. Flow is
controlled in the direction from
port 2 to port 1, from full flow
to tight shut-off, by turning the
adjustment feature clockwise.
The flow from port 1 to port 2
will be restricted.
Pressure Drop Curves
Cartridge only
Features
Hardened and ground working
components. Cartridge
construction for maximum
mounting flexibility.
Pressure drop - psi
Pressure drop - bar
Flow - USgpm (105 SUS oil @ 120°F)
Flow - L/min (21,8 cSt oil @ 49°C)
70
60
50
40
30
20
10
0
5
4
3
2
1
0
0 40 80 120 160 200 240
0 10 20 30 40 50 60 70
Description
This is a manually adjusted
cartridge type needle valve.
With fine control it is ideal
for none compensated speed
control of actuators or as a
control orifice in conjunction
with a pressure compensator
Total shut off can be achieved
allowing the valve to be used
as a shut of valve.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 265 L/min (70 USgpm)
Internal leakage 5 drops/min maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Cavity C–20–2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration
Cleanliness code 18/16/13
Standard housing material Aluminum
Weight cartridge only 0,59 kg. (1.3 lbs)
Seal kit 889615 (Buna-N), 889619 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
Sectional View
2
1
Full open port 2 to port 1
1