EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-330.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
MRV2-16 - Flow Restrictor Valve
Semi-rotary
Up to 170 L/min (45 USgpm) • 210 bar (3000 psi)
Operation
This valve will increase or
decrease flow by changing the
variable orifice with the rotary
adjustment. Recommended flow
path is 2 to 1.
Pressure Drop Curves
Cartridge only
@ 5,5 bar (80 psi) pressure drop
Features
Hardened and ground working
components. Cartridge
construction for maximum
mounting flexibility. Flexible
mounting for the handle
position, detent available.
9
8
7
6
5
4
3
2
1
20 40 60 80 100 120 140 160 180
0 4 8 12 16 20 24 28 32 36 40 44
A B C D E G H
Knob lever position
Flow - USgpm (105 SUS oil @ 20°F)
Flow - L/min (21,8 cSt oil @ 49°C)
F
Description
This is a 2 way 2 position
manually operated semi
rotary restrictor screw in
cartridge valve. This can be
used in conjunction with
a compensator to give an
increase in flow in proportion
to the movement of the lever.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Rated inlet flow 10 – 0-37,8 L/min (0–10 USgpm)
15 – 0-56,7 L/min (0–15 USgpm)
20 – 0-75,7 L/min (0–20 USgpm)
25 – 0-94,6 L/min (0–25 USgpm)
30 – 0-113,5 L/min (0–30 USgpm)
35 – 0-132,4 L/min (0–35 USgpm)
40 – 0-151,4 L/min (0–40 USgpm)
45 – 0-170,3 L/min (0–45 USgpm)
Internal leakage 82 cm
3
/min (5 in
3
/min
maximum 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Manual Operators D – Lever (10 position detent)*
L – Lever (friction lock)*
*Light duty housing only. K – Knob (non-locking)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration
Cleanliness code 18/16/13
Standard housing material Aluminum
Weight cartridge only 0,79 kg (1.74 lbs)
Seal kit 565810 (Buna-N), 889609 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
Sectional View
Rated flow (See model code position 6)
A - 10
B - 15
C - 20
D - 25
E - 30
F - 35
G - 40
H - 45
2
1
2
1