EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-590.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
FDC1-16 - Flow Divider/Combiner
Pressure compensated, spool type
Up to 178 L/min (47 USgpm) 210 bar (3000 psi)
Description
This range of flow divider/
combiner valves gives division
of input flow into two equal
parts and re-combination of
flow in the reverse direction.
Pressure compensation
ensures that whether dividing
or combining, equal flow
is maintained over a wide
range of pressure variation.
A typical use of these valves
is to divide a pump flow to
operate two actuators (which
may be under different load
conditions and at different
pressures) and to re-combine
the return flows to synchronize
actuator movement. Flow
variation is within ±10% with
the maximum variation of
pressure and inlet flow and
under normal conditions will
be significantly less.
Operation
Inlet flow passes through the
two matched orifices in the
spools, through the spools and
out of the radial holes in the
sleeve. The matched orifices
and the compensating springs
ensure that the flow is divided
equally, excess flow
in either direction causes the
spool to move and close the
radial holes in the sleeve until
equilibrium is restored. In the
reverse direction the spools
close together and regulate
the flow in through the radial
ports.
Features
One valve synchronizes in
both directions. Matched
spools give high accuracy
under load and pressure
imbalance conditions.
Cartridge construction gives
versatility of application. A
valve may be fitted into a
line body, a custom designed
Hydraulic Integrated Circuit or
other hydraulic equipment.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated inlet flow See model code
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C–16–4
Fluids All general purpose hydraulic fluids such as
MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,35 kg (0.78 lbs)
Seal Kits 889634 (Buna–N)
889638 (Viton
®)
Viton is a registered trademark of E.I. DuPont
Performance Data
Sectional View
Pressure Drop
Cartridge only
Flow - USgpm (105 SUS oil @ 120°F)
Pressure drop - psi
Pressure drop - bar
Flow - L/min (21,8 cSt oil @ 49°C)
800
700
600
500
400
300
200
100
0
0 5 10 15 20 25 30 35 40 45 50
A C D
E
F
10
20
30
40
50
50 100 150 200
B
Flow Division
(See model code position 5)
A - 2* spool
B - 3* spool
C - 4* spool
D - 5* spool
E - 6* spool
F - 8* spool
4
3
2
4
3
2
1
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-591.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
FDC1-16 - Flow Divider/Combiner
Pressure compensated, spool type
Up to 178 L/min (47 USgpm) 210 bar (3000 psi)
1
Function
FDC1 - Flow divider/combiner
2
Size
16 - 16 size
Code Port Size Housing Number
Aluminium Light Duty
0 Cartridge only
12T SAE 12 566200
6B 3/4" BSPP 02-175468
See section J for housing details.
4
Port Size
104,8
(4.12)
1.312"-12 Thd.
38,1 (1.50) hex
Ø25,37 (0.999)
Ø26,95 (1.061)
Ø28,55 (1.124)
13,0
(0.51)
4
3
2
Torque cartridge in aluminum
housing to 108–122 Nm
(80–90 ft lbs)
Model Code
2 3 41
FDC1
16
(V) ***
5
**
6
00
5
Flow Divisions (Ratios)
Code Flow Division % Rated Inlet Flow
Port 4 Port 2 L/min (USgpm)
22 50 50 045,6 (12)
28 20 20 114,0 (30)
33 50 50 068,0 (18)
36 33 67 098,0 (26)
43 57 43 079,0 (21)
44 50 50 090,0 (24)
46 40 60 114,0 (30)
55 50 50 114,0 (30)
62 75 25 090,0 (24)
63 67 33 098,0 (26)
64 60 40 114,0 (30)
66 50 50 132,0 (35)
82 80 20 114,0 (30)
84 67 33 132,0 (35)
88 50 50 178,0 (47)
Dimensions
mm (inch)
Cartridge Only
Basic Code
FDC1-16
6
Special Features
00 - None
(Only required if valve has special features, omitted if “00”.)
3
Seals
Blank - Buna-N
V - Viton
®
Notes: Port 1, unused,
blocked by blind cavity.
Minimum inlet flow should not
be less than 1/4 of maximum
inlet flow for a given code.