EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-190.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
FAR1-16 - Flow Regulator
Fully adjustable, pressure compensated with free reverse flow
3.8-114 L/min (1-30 USgpm) 310 bar (4500 psi)
Operation
Flow into the inlet of the valve
passes through the adjustable
orifice and out of the regulated
port. The pressure drop across
the orifice is sensed on the
regulating sleeve and produces
a force which, at the required
flow rate, overcomes
Typical Flow Regulation
Cartridge only
the spring force. The resultant
movement of the sleeve
regulates the flow by closing
the radial valve ports.
The inbuilt check allows free
return of flow (2 to 1).
Features
Cartridge construction gives
versatility of application. A
valve may be fitted into a
line body, a custom designed
Hydraulic Integrated Circuit or
directly into a cylinder or
other actuator. Leakproof
adjust screw gives easy,
accurate adjustment to
required flow setting.
Hardened and ground working
parts give accurate flow
control and long working life.
Pressure differential across valve in psi
Pressure differential across valve in bar
TYPICAL FLOW REGULATION
PRESSURE DROP FOR REVERSE FLOW
Flow - L/min (21,8 cSt oil @ 49°C)
Flow - USgpm (105 SUS oil @ 120°F)
120
100
80
60
40
20
36
30
24
18
12
6
100 240 300 350
1000 2000 3000 4000 5000
200
150
100
50
0 6 12 18 24 36
4
8
12
20 40 60 80 100 120
30
Pressure drop - psi
Pressure drop - bar
Flow - USgpm
(105 SUS oil @ 120°F)
Flow - L/min
(21,8 cSt oil @ 49°C)
Sectional View
Description
This is a two-port, restrictive
flow regulator with a built in
free flow check valve. Typical
uses include the control of
actuator speed by regulating
the flow into or out of the
actuator (meter-in or
meter-out).
The flow (and actuator speed)
will be largely independent
of the load and the pressure
conditions. If used to restrict
flow from a fixed supply, for
example a standard gear or
piston pump, the valve will
pass the required flow and any
surplus flow will normally pass
over the system relief valve.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 350 bar (5000 psi)
Min. pressure differential across valve 17 bar (250 psi)
Max. pressure differential across valve 328 bar (4750 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 3,8–113,6 L/min (1–30 USgpm)
Temperature range 40° to 120°C (–40° to 248°F)
Flow regulation accuracy 3,8–15,1 L/min (1.0–4.0 USgpm) ±30% @5000 psi
above 15,1–30,3 L/min (above 4.0–8.0 USgpm) ±20% @5000 psi
above 30,3–113,6 L/min (above 8.0–30.0 USgpm) ±10% @5000 psi
Factory set maximum flow rate accuracy under
standard test conditions and within the above ranges
Reverse check crack pressure 1.7 bar (25 psi)
Leakage at shutoff position 0,55 L/min (33.5 in3/min)
Cavity C–16–2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration
Cleanliness code 18/16/13
Standard housing material Aluminum or steel
Weight cartridge only “S” 0,67 kg (1.48 lbs)
“K” 0,70 kg (1.55 lbs)
“H” 0,74 kg (1.62 lbs)
Seal kit 565810 (Buna-N)
889609 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
1
2
1
2
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-191.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
7 Factory Set Flow
Rate
Blank - Normal factory setting
at 15 USgpm User
requested setting
Within 1-30 USgpm
(3,8-113,6 L/min.)
8 Special features
00 – None
(Only required if valve has
special features, omitted if “00”)
FAR1-16 - Flow Regulator
Fully adjustable, pressure compensated with free reverse flow
3.8-114 L/min (1-30 USgpm) 310 bar (4500 psi)
30,5
(1.20)
38,1
(1.50)
"H" Adjustment
"K" Adjustment
"S" Adjustment
4,75 (0.19) hex
94,5
(3.72)
101,9
(4.01)
max.
Ø38,1
(1.50)
82,1
(3.40)
79,1
(3.11)
max.
38,1
(1.50)
hex
79,1
(3.11)
1.312"12 T hd.
28,5
(1.12)
46,4
(1.83)
Model Code
FAR1 16 (V) * * ** *.* 00
1 2 3 4 5 6 7 8
Code Port Size Housing Number
Aluminium Aluminium Steel
Light duty Fatigue rated Fatigue rated
4G 1/2" BSPP 876716 02-175106
6B 3/4" BSPP 02-175463
6G 3/4" BSPP 876718 02-175107
10T SAE 10
10H SAE 10 876717 02-175104
12T SAE 12 566149
12H SAE 12 566113 02-175105
See section J for housing details.
6 Port Size
1 Function
FAR1 - Flow adjustable,
pressure compensated
flow regulator with
reverse flow check
2 Size
16 - 16 Size
3 Seal material
Blank - Buna-N
V - Viton
®
Torque cartridge in housing
A - 108–122 Nm (80–90 ft lbs)
S - 136–149 Nm (100–110 ft
lbs)
Note: To reset scale and
knob to an optimum viewing
position:
1. Loosen the set screw
2. Rotate zero point on scale
to a desired orientation.
3. Align mark on knob with
zero on scale.
4. Tighten the set screw
rmly.
Note: To change the setting:
1. Loosen the set screw
2. Loosen jamnut while
holding the knob steady, or
move the knob along the
axis slightly.
3. Turn adjusting screw (jam
nut and knob will turn at the
same time).
4. At the new adjusting screw
position, tighten jamnut
rmly while holding the
knob steady, or move the
knob along the axis slightly.
5. Tighten the set screw
rmly.
Dimensions
mm (inch)
Cartridge
Basic Code
FAR1-16
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
4 Adjustment
H - Calibrated handknob
with locknut
K - Handknob with locknut
S - Screw with locknut
5 Valve Housing
Material
Omit for cartridge only
A - Aluminum
S - Steel
Installation Drawing (Steel)
88.9
(3.50)
63.5
(0.25)
79.1
(3.11)
25.4
(1.00)
1
2
2X Ø10.31
(0.406)
63.5
(2.50)
76.2
(3.00)
12.7
(0.50)
25.4