EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-170.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 5–350 bar (75–5000 psi) steel housing
Min. pressure differential across valve 14 bar (200 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 1–38 L/min (0.25–10 USgpm)
Temperature range 40° to 120°C (–40° to 248°F)
Flow regulation accuracy 4–38 L/min (1–10 USgpm) ±10%
1–4 L/min (0.25–1 USgpm) ±20%
Factory set maximum flow rate accuracy under
standard test conditions and within the above ranges
Reverse check crack pressure 1.7 bar (25 psi)
Leakage at shutoff position 0.4 L/min (24.4 in3/min)
Cavity C-10-2
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration
Cleanliness code 18/16/13
Standard housing material Aluminum or Steel
Weight cartridge only “S” 0,02 kg (0.44 lbs)
“K” 0,23 kg (0.51 lbs)
“H” 0,26 kg (0.59 lbs)
Seal kit 565803 (Buna-N), 566086 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
FAR1-10 - Flow Regulator
Fully adjustable, pressure compensated with free reverse flow
1-38 L/min (0.25-10 USgpm) 310 bar (4500 psi)
Operation
Flow into the inlet of the valve
passes through the adjustable
orifice and out of the regulated
port. The pressure drop across
the orifice is sensed on the
regulating sleeve and produces
a force which, at the
Performance Data
Typical Flow Regulation
Cartridge only
required flow rate, overcomes
the spring force. The resultant
movement of the sleeve
regulates the flow by closing
the radial valve ports.
The inbuilt check allows free
return of flow (2 to 1).
Features
Cartridge construction gives
versatility of application. A
valve may be fitted into a
line body, a custom designed
Hydraulic Integrated Circuit or
directly into a cylinder or other
actuator. Leakproof adjust
screw gives easy, accurate
adjustment to required flow
setting. Hardened and ground
working parts give accurate
flow control and long working
life.
10
12
6
8
Pressure differential across valve in psi
1000 2000 3000 4000 5000
70 140 210 280 350
40
32
24
16
8
Pressure differential across valve in bar
0
TYPICAL FLOW REGULATION
PRESSURE DROP FOR REVERSE FLOW
Flow - L/min (21,8 cSt oil @ 49ºC)
Flow - USgpm (105 SUS oil @ 120°F)
200
150
100
50
0 2 4 6 8 10 12
4
8
12
8 16 24 32 40
4
2
Flow -L/min
(21,8 cSt oil @ 49°C)
Flow - USgpm
Pressure drop - bar
Pressure drop - psi
(105 SUS oil @ 120°F)
Sectional View
Description
This is a two-port, restrictive
flow regulator with a built in
free flow check valve. Typical
uses include the control of
actuator speed by regulating
the flow into or out of the
actuator (meter-in or
meter-out).
The flow (and actuator speed)
will be largely independent
of the load and the pressure
conditions. If used to restrict
flow from a fixed supply, for
example a standard gear or
piston pump, the valve will
pass the required flow and any
surplus flow will normally pass
over the system relief valve.
1
2
1
2
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-171.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
7 Factory Set Flow Rate
Blank - Normal factory setting
at 5 USgpm User
requested setting
within .25–10 US gpm
(1-–38 L/min.)
8 Special features
00 – None
(Only required if valve has
special features, omitted if “00”)
FAR1-10 - Flow Regulator
Fully adjustable, pressure compensated with free reverse flow
1-38 L/min (0.25-10 USgpm) 310 bar (4500 psi)
0.875"–14
Thd.
31,8
(1.25)
2
"S"
adjustment
4,75 (0.19) hex
25,4
(1.00)
hex
Ø15,8 (0.62)
1
56,9
(2.24)
61,1
(2.40)
max.
"K" adjustment
"H" adjustment
30,5
(1.20)
38,1
(1.50)
72,4
(2.85)
76,5
(3.01)
max.
Ø38,1
(1.50)
Model Code
FAR1 10 (V) * * ** *.* 00
1 2 3 4 5 6 7 8
Code Port Size Housing Number
Aluminium Aluminium Steel
Light duty Fatigue rated Fatigue rated
0 Cartridge only
3B 3/8" BSPP 02–175462
2G 1/4" BSPP 876702 02-175102
3G 3/8" BSPP 876703 02-175103
6H SAE 6 876700
8H SAE 8 876701
6T SAE 6 566151 02-175100
8T SAE 8 02-175101
See section J for housing details.
6 Port Size
Torque cartridge in housing
A - 47-54 Nm (35-40 ft lbs)
S - 68-75 Nm (50-55 ft lbs)
“K” adjustment kit – 565585
Note: To reset scale and
knob to an optimum viewing
position:
1. Loosen the set screw
2. Rotate zero point on scale
to a desired orientation.
3. Align mark on knob with
zero on scale.
4. Tighten the set screw
rmly.
Note: To change the setting:
1. Loosen the set screw
2. Loosen jamnut while
holding the knob steady, or
move the knob along the
axis slightly.
3. Turn adjusting screw (jam
nut and knob will turn at the
same time).
4. At the new adjusting screw
position, tighten jamnut
rmly while holding the
knob steady, or move the
knob along the axis slightly.
5. Tighten the set screw
rmly.
1 Function
FAR1 - Flow adjustable,
pressure compensated
flow regulator with
reverse flow check
2 Size
10 - 10 Size
3 Seal Material
Blank - Buna-N
V - Viton
®
4 Adjustment Means
H - Calibrated handknob
with locknut
K - Handknob with locknut
S - Screw with locknut
5 Valve Housing
Material
Omit for cartridge only
A - Aluminum
S - Steel
Dimensions
mm (inch)
Cartridge
Basic Code
FAR1-10
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
Installation Drawing (Steel)
63.5
(2.50)
9.5
(0.37)
44.5
(1.75)
2 X Ø7.14
(0.281)
19
(0.75)
44.45
(1.750)
50.8
(2.00)
63.5
(2.50)
1
2
22.2
(0.87)
58.7/62.7 Max