EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009H-550.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Figures based on oil temperature of 40˚ C and of 32 cSt (150 SUS)
Rated flow Inlet 2FPH55 95 L/min (25 USgpm)
2FPH95 150 L/min (40 USgpm)
2FPH195 380 L/min (100 USgpm)
Regulated 2FPH55 55 L/min (14 USgpm)
2FPH95 95 L/min (25 USgpm)
2FPH195 160 L/min (42 USgpm)
Maximum pressure 2FPH55 280 bar (4000 psi)
2FPH95/2FPH195 350 bar (5000 psi)
Material All working parts hardened & ground steel
Standard housing material 2FPH55 Aluminum (up to 210 bar)
2FPH95/2FPH195 Steel
Mounting position Line mounted
Weight 2FPH55 3.00 Kg (6.60 lbs)
2FPH95 3.50 Kg (7.70 lbs)
2FPH195 12.26 Kg (27.00 lbs)
Seal kit number 2FPH55 SK267 (Nitrile) SK267V (Vition)
2FPH95 SK547 (Nitrile) SK547V (Viton)
2FPH195 SK258 (Nitrile) SK258V (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating temperature –30° to +90°C (–22° to +194°F)
Nominal range 5 to 500 cSt
Viton is a registered trademark of E.I. DuPont
Operation
Inlet flow passes through
the adjustable orifice and
the radial holes in the spool/
sleeve assembly then out
of the regulated port. The
pressure drop across the
orifice is sensed at each end
of the spool, producing a force
which, at the required flow
rate, overcomes the spring
force. The resultant movement
of the spool regulates the flow
by opening the radial valve
ports to the bypass port and
closing the regulated
flow ports. The solenoid valve
vents the spring chamber to a
drain line and in its NORMAL
(de-energized) mode all inlet
flow is diverted to the bypass
port. The pre-set regulated
flow is selected by energizing
the solenoid. The adjustable
relief valve vents the spring
chamber at the pre-set
pressure and diverts the flow
to the bypass port. It may
be necessary to fit a 10 bar
check valve in the bypass or
regulated line to ensure the
valve switches fully.
Features
Line body construction with
three ports allows direct
connection into hydraulic
systems. Leakproof adjust
screw gives easy, accurate
adjustment to required flow
setting. Remote functional
selection with solenoid
operation. Adjustable relief
valve gives system protection.
Hardened and ground working
parts give accurate flow
control and long working life.
Pressure Drop
Performance Data
2FPH - Flow Regulator
Pressure compensated regulator/diverter, priority style. solenoid switch
Up to 160 L/min (42 USgpm) 350 bar (5000 psi)
Sectional View
Description
The 2FPH series of priority
flow regulator valves gives full
control of regulated flow plus
remote selection of priority
flow and adjustable pressure
limitation of the regulated line.
Inlet (1)
By-pass (3)
Drain (4)
Reg.(2)
Inlet
(1)
Inlet
Bypass
(3)
Reg
(2)
1
2
3
4
Load pressure - psi
Regulated ow - L/min
Regulated ow - US gpm
Load pressure - bar
2800 1400 0 1400 2800
290
235
165
115
60
0
65
52
39
26
13
0
2FPH195
200 100 0 100 200
Bypass higher than
regulated pressure
Regulated higher than
bypass pressure
2FPH95
Load pressure - psi
Regulated ow - L/min
Regulated ow - US gpm
Load pressure - bar
2800 1400 0 1400 2800
65
55
45
35
25
15
0
15
12.5
10
7.5
5
2.5
0
2FPH55
200 100 0 100 200
Bypass higher than
regulated pressure
Regulated higher than
bypass pressure
60
50
40
30
20
10
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 H-551.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
1 Basic Code
2FPH55 - Complete valve
2FPH95 - Complete valve
2FPH195 - Complete valve
Model Code
4 Adjustable Flow
Range
2FPH55 - 0-55 liters/min
2FPH95 - 0-95 liters/min
2FPH195 - 0-195 liters/min
5 Seals
S - Nitrile (for use with most
industrial hydraulic oils)
SV - Viton
(for high
temperature & most
special uid applications)
Dimensions
mm (inch)
1 2 3 4 5 6 7
3 Port Size - Bodied
Valves Only
4W - 1/2" BSP
6W - 3/4" BSP
8W - 1" BSP
8T - 1/2" SAE
12T - 3/4" SAE
16T - 1" SAE
2 Adjustment means
P - Leakproof screw
adjustment
R - Handknob adjustment (See
page H-6 for dimensions)
6 Coil Termination
H - ISO 4400 (plug included)
F - Flying leads, DC only
DM - Deutsch moulded
Other terminations available on
request
7 Voltage
12 - 12 VDC
24 - 24 VDC
Other options available on request
2FPH - Flow Regulator
Pressure compensated regulator/diverter, priority style. solenoid switch
Up to 160 L/min (42 USgpm) 350 bar (5000 psi)
2FPH** P 6W 95
S H 24
Complete Valve
Basic Code
2FPH
Note: For applications above
210 bar please consult our
technical department or use
the steel body option
Code Port Size A B C D E F G H K L M N O P Std R/V
2FPH55 1/2" 168 51 76 127 44.5 82.5 - 32 28.5 8.5 10 95 Ø8.5 SX203 280 bar
2FPH95 3/4" 232 63.5 76 127 58 102 58 39.5 32 10 10 136 Ø10.5 S207 200 bar
2FPH195 1" 227.5 63.5 133 168 47 104 108 32 67 13 13 127 Ø13.5 S207 280 bar
M
C
K
B
H
D
G
E
F
A
N
1
2
3
P
1DR2-P-40S
4
Tank drain
line
Do not block
1/4” BSP
(1/4” SAE)
O
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009560.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Figures based on oil temperature of 40˚ C and of 32 cSt (150 SUS)
Rated flow Inlet 2FPH250 350 L/min (92 USgpm)
2FPH350 450 L/min (120 USgpm)
Regulated 2FPH250 200 L/min (52 USgpm)
2FPH350 350 L/min (92 USgpm)
Maximum pressure 350 bar (5000 psi)
Material All working parts hardened & ground steel
Standard housing material Steel, zinc plated and passivated
Mounting position Line mounted
Weight 2FPH250 17 kg (37.4 lbs)
2FPH350 28 kg (61.0 lbs)
Seal kit number 2FPH250 SK819 (Nitrile), SK819V (Viton
®
)
2FPH350 SK820 (Nitrile), SK820V (Viton
®
)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating temperature -30° to +90° C (–22° to +194° F)
Nominal range 5 to 500 cSt
Viton is a registered trademark of E.I. DuPont
Operation
Inlet flow passes through
the adjustable orifice and
the radial holes in the spool/
sleeve assembly then out
of the regulated port. The
pressure drop across the
orifice is sensed at each end
of the spool, producing a force
which, at the required flow
rate, overcomes the spring
force. The resultant movement
of the spool regulates the
flow by opening more radial
holes to the bypass port. The
solenoid valve vents the spring
chamber to a drain line
and in its de-energized mode
all inlet flow is diverted to
the bypass port. The pre-set
regulated flow is selected by
energizing the solenoid. The
adjustable pilot valve vents
the spring chamber when the
regulated line reaches the
preset pressure, diverting the
flow to the bypass port where
the pressure can continue
to rise if necessary. It may
be necessary to fit a 10 bar
check valve in the bypass or
regulated line to ensure the
valve switches fully.
Features
Line body construction with
three ports allows direct
connection into hydraulic
systems. Leakproof adjust
screw gives easy, accurate
adjustment to required flow
setting. Remote functional
selection with solenoid
operation. Adjustable relief
valve gives system protection
whilst allowing bypass
pressure to rise above setting
if required. Hardened and
ground working parts give
accurate flow control and long
working life.
Performance Data
2FPH - Flow Regulator
Pressure compensated regulator/diverter, priority style. solenoid switch
350 L/min (92 USgpm) 350 bar (5000 psi)
Description
The 2FPH series of priority
flow regulator valves gives full
control of regulated flow plus
remote selection of priority
flow and adjustable pressure
limitation of the regulated line.
Pressure Drop
Inlet
By-pass
Drain
Reg.
LS
Load pressure - psi
Regulated ow - L/min
Regulated ow - US gpm
Load pressure - bar
4000 2000 0 2000 4000
300
250
200
150
100
50
0
78
65
52
39
26
13
0
2FPH250
300 150 0 150 300
Bypass higher than
regulated pressure
Regulated higher than
bypass pressure
Load pressure - psi
Regulated ow - L/min
Regulated ow - US gpm
Load pressure - bar
4000 2000 0 2000 4000
300
250
200
150
100
50
0
78
65
52
39
26
13
0
300 150 0 150 300
Bypass higher than
regulated pressure
Regulated higher than
bypass pressure
2FPH350
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 561.A
An Eaton Brand
H
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
A
Inlet
F
Ø Q
Tank
drain line
Do not
block
C
B
G
M
R
S
N
P
F
Bypass
Reg
LS
D
J
L
H
K
D
E
Load
sensing
port
1/4” BSP
(1/4” SAE)
1 Basic code
2FPH250 - Complete valve
2FPH350 - Complete valve
Model Code
4 Adjustable Flow
Range
250 - 0-250 L/min (2FPH250)
350 - 0-350 L/min (2FPH350)
5 Seals
S - Nitrile (for use with most
industrial hydraulic oils)
SV - Viton (for high
temperature & most
special uid applications)
Dimensions
mm (inch)
1 2 3 4 5 6 7
3 Port size - bodied
valves only
8W - 1" BSP
12W - 1 1/2" BSP
16T - 1" SAE
24T - 1 1/2" SAE
2 Adjustment means
P - Leakproof Screw
Adjustment
6 Coil termination
H - ISO 4400 (plug included)
F - Flying leads, DC only
DM - Deutsch mouldedOther
terminations available on request
7 Voltage
12 - 12 VDC
24 - 24 VDC
Other options available on
request
2FPH - Flow Regulator
Pressure compensated regulator/diverter, priority style. solenoid switch
350 L/min (92 USgpm) 350 bar (5000 psi)
2FPH*** P 8W 250
S H 24
Complete Valve
Basic Code
2FPH
Basic Code Port Size A B C D E F G H K L M N O P O R S Std R/V
2FPH250 1" 177 63.5 177.8 75 70 31.75 143 47.5 105 15 62 110 95 63 13.5 - - 280 bar
2FPH350 1-1/2" 269 76.2 177.8 75 70 38.1 100 89 164 5 62 15 100 39 18.0 90 50 200 bar