EATON Screw-In Cartridge Valves E-VLSC-MC001-E November 2009 I-130.A
An Eaton Brand
I
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F)
Typical application pressure Spool type: 290 bar (4200 psi)
Poppet type: 210 bar (3000 psi) or 350 bar (5000 psi)
Rated flow 303 L/min (80 USgpm)
Pilot ratio Spool type P, V, R, F: 1:1
Poppet type B, S, T: 2:1
Internal leakage Spool type: 82 cm
3
/min. (5 in
3
/min) max @ 290 bar (4200 psi)
Poppet type: Port 1 to 2:< 5 drops/min max @ 350 bar (5000 psi)
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-20-3S
Standard housing materials Aluminium
Fluids All general purpose hydraulics fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,81 kg (1.78 lbs)
Seal kit 02-113153 (Buna-N), 02-112969 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
DPS2-20 - Logic Element
Differential pressure sense valves
303 L/min (80 USgpm) • 210, 350 bar (3000, 5000 psi)
Operation
This valve is used as a main
section of a pilot controlled
valve assembly. This valve has
multiple uses when used with
either directional control, flow
control or pressure control
cartridges. Refer to application
examples.
Features
Hardened and ground and
honed working components.
Cartridge construction for
maximum mounting flexibility.
Low leakage with poppet
valves and 350 bar pressure
rating.
Pressure Drop Curve
Cartridge only
Performance DataSectional View
B/S/T models
P/V models
F/R models
0
2
4
6
8
10
12
14
16
0
50
100
150
200
250
0 4 0 8 0 120 160 200 240 280
Flow - L/min (21,8 cSt oil @ 49° C)
Flow - USgpm (105 SUS oil @ 120° F)
Pressure drop - bar
0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0
Description
These are normally open or
closed logic elements with or
without a control orifice. They
can be used as main valves
for the control of high flows
using small pilot cartridges, as
compensators or load sense
elements.
Functional Symbols
See pages I-142 & I-143
3
1
2