EATON Screw-In Cartridge Valves E-VLSC-MC001-E November 2009 I-110.A
An Eaton Brand
I
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F)
Typical application pressure Spool type: 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
Pilot ratio Spool type P, V, R, F: 1:1
Poppet type B, S, T: 2:1
Internal leakage Spool type: 82 cm
3
/min. (5 in
3
/min) max @ 350 bar (5000 psi)
Poppet type: Less than 5 drops/min @ 3000 psi
Temperature range -40° to 120° C (-40° to 248° F)
Cavity C-12-3S
Standard housing materials Aluminium or steel
Fluids All general purpose hydraulics fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc
Filtration Cleanliness code 18/16/13
Weight cartridge only 0,31 kg (0.68 lbs)
DPS2-12 - Logic Element
Differential pressure sense valves
114 L/min (30 USgpm) • 350 bar (5000 psi)
Operation
This valve is used as a main
section of a pilot controlled
valve assembly. This valve has
multiple uses when used with
either directional control, flow
control or pressure control
cartridges. Refer to application
examples.
Features
Hardened and ground and
honed working components.
Cartridge construction for
maximum mounting flexibility.
Low leakage with poppet
valves and 350 bar pressure
rating
Pressure Drop Curve
Cartridge only
Performance Data
Sectional View
Functional Symbols
See pages I-142 & I-143
1
2
3
0
0 5 10 15 20 25 30
0 19 38 60 76 95 114
50
100
150
200
250
0
3.4
6.8
10.3
13.8
17.2
Flow (GPM)
Pressure Drop 1 to 2 in psi
B / S / T model
P / V model
F / R model
Flow - L/min
Pressure drop 1 to 2 in bar
B/S/T models
P/V models
F/R models
Description
These are normally open or
closed logic elements with or
without a control orifice. They
can be used as main valves
for the control of high flows
using small pilot cartridges, as
compensators or load sense
elements.