Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 K-240.A
An Eaton Brand
K
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range 7-210 bar (100-3000 psi)
Maximum inlet flow 152 L/min (40 USgpm)
Regulated flow range 1.9-113 L/min (0.5-30 USgpm)
Internal leakage 82 cm
3
/min (5 in
3
/min) max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL -H-5606, SAE 10, SAE 20, etc.
Description
Fixed priority flow control with
relief on priority flow port.
Operation
This standard valve package is
used to maintain constant flow
to priority circuits when input
flow is greater than required,
regardless of changes in
upstream or downstream pres-
sure. It will bypass the rest of
the flow to an auxiliary circuit
or to tank.
Relief valve on a priority port
limits pressure on a prior-
ity port, as well as ensures
bypass flow when there is no
demand on priority circuit.
Features
Priority flow pressure com-
pensation, all ports except T
can be pressurized to 210 bar
(3000 psi). Aluminum in-line
type housing, tamper proof
and adjustable relief options,
gauge port. All components in
the package are true cartridges
and can be removed from the
housing without disturbing the
plumbing.
Typical Flow Regulation
Performance Data
PFRR-16 - Flow Control
Pressure compensated, priority type, with relief on priority flow
152 L/min (40 USgpm) • 7-210 bar (100-3000 psi)
A - Port 3, priority
(regulated)
outlet pressurized
B - Port 2, bypass
outlet pressurized
50 100 140 210
0 1000 2000500 1500 2500
0
B ack Pressure - bar
Ba ck P ressure - psi
3000
A
B
A
(105 SUS oil @ 1 20˚ F )
(21,8 cSt oil @ 49˚ C )
B
0
1
2
3
4
5
6
0
4
8
12
16
20
24
P
T
Bypass
G
Priority
flow