Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 K-210.A
An Eaton Brand
K
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range (all ports) 10-210 bar (150-3000 psi)
Maximum regulated flow Up to 228 L/min (60 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL -H-5606, SAE 10, SAE 20, etc.
Description
Pump control manifold for mul-
tiple pump circuits.
Operation
This standard valve package is
used to provide air-bleed, start-
up and relief protection for
each pump in multiple pump
circuits. The check valve posi-
tion in the circuit isolates the
other pumps from the valve
assembly.
Features
Individual relief pressure set-
ting for each pump in the
system, multiple tank ports for
mounting convenience, direct
reservoir mounting capability
by using T port. Both T port
and mounting holes have
O-ring seals mounting surface.
Aluminum in-line type housing,
tamper proof and adjustable
relief options, gauge port. All
components in the package
are true cartridges and can
be removed from the housing
without disturbing the plumbing.
Pressure Drop
Performance Data
PCC2-16 - Pump Control
Multiple pump circuits
Up to 228 L/min (60 USgpm) • 10-210 bar (150-3000 psi)
Pressure Override
�
10 20 30 400
25
50
75
100
125
40 80
150
50 60
2
4
6
8
10
120 160
200 240
1000
2000
3000
4000
5000
6000
20 400
60 80
00
138
69
210
276
345
414
50 100 150 200
250 300
Pressure Drop - psi
Flow - L/min (21,8 cSt oil @ 49˚ C )
Pressure Drop - bar
Flow - USgpm (1 05 SUS oil @ 1 20˚ F ) Flow - USgpm (1 05 SUS oil @ 1 20˚ F )
Inlet pressure - psi
Flow - L/min (21,8 cSt oil @ 49˚ C )
Inlet pressure - bar
P
T