Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 K-190.A
An Eaton Brand
K
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range (all ports) 10-210 bar (150-3000 psi)
Maximum regulated flow Up to 228 L/min (60 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL -H-5606, SAE 10, SAE 20, etc.
Description
Pump control manifold for
single pump circuits.
Operation
This standard valve package is
used for air-bleed and start-up
in single pump power units.
It also provides main system
relief protection.
Features
Multiple tank ports for mount-
ing convenience, direct res-
ervoir mounting capability by
using T port. Both T port and
mounting holes have O-ring
seals mounting surface.
Aluminum in-line type housing,
Tamper proof and adjustable
relief options, gauge port. All
components in the package
are true cartridges and can
be removed from the housing
without disturbing the plumbing.
Pressure Drop
Performance Data
PCC1-16 - Pump Control
Single pump circuits
Up to 228 L/min (60 USgpm) • 10-210 bar (150-3000 psi)
Pressure Override
10 20 30 400
25
50
75
100
125
40 80
150
1000
2000
3000
4000
5000
6000
50 60
20 400
60 80
00
138
69
210
276
345
414
2
4
6
8
10
120 160
200 240
50 100 150 200
250 300
Flow - L/min (21,8 cSt oil @ 49˚ C )
Pressure Drop - bar
Flow - USgpm (1 05 SUS oil @ 1 20˚ F )
Pressure Drop - psi
Inlet pressure - psi
Flow - L/min (21,8 cSt oil @ 49˚ C )
Inlet pressure - bar
Flow - USgpm (1 05 SUS oil @ 1 20˚ F )
P