Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 K-480.A
An Eaton Brand
K
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
1CEOMS95/1CEEOMS95 - Motor Mounted Valves
OMS Mounting Pattern Single and Dual Overcenter Valves
Operation
The check section allows
free flow into the actuator
then holds and locks the load
against movement. The pilot
assisted relief valve section
will give controlled movement
when pilot pressure is applied.
The relief section is normally
set to open at a pressure at
least 1.3 times the maximum
load induced pressure but the
pressure required to open the
valve and allow movement
depends on the pilot ratio of
the valve. For optimization
of load control and energy
usage, a choice of pilot ratios
is available.
The pressure required to open
the valve and start actuator
movement can be calculated
as follows:
Pilot Pressure =
(Relief Setting) - (Load Pressure)
Pilot Ratio
Description
Overcenter valves give
static and dynamic control
of loads by regulating the
flow into and out of hydraulic
actuators. When installed
close to or within an actuator,
the overcenter valve will
stop runaway in the event
of hose burst and if open
center directional control
valves are used, will allow
thermal expansion relief of
the hydraulic fluid.
The overcenter cartridge is
ideal for mounting directly
into a cavity machined in the
body of the cylinder, motor or
rotary actuator. The cartridge
can also be mounted directly
to the ports via a specifically
machined body as part of a
Hydraulic Integrated Circuit
or single unit, or contained
within one of our standard
line bodies.
Single overcenter valves are
normally used when the load
is unidirectional, for example
an aerial platform or crane
and dual overcenter valves
are used for controlling loads
in both directional for motor
applications or for cylinders
going over center.
Pilot Ratios
4:1 Best suited for
applications where load
varies and machine
structure can induce
instability
8:1 Best suited for
applications where the
load remains relatively
constant.
Other ratios available
upon request
1CEOMS95-1 1CEOMS95-2
1CEEOMS95
Ratings and Specifications
Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
Rated flow 90 L/min (23 USgpm)
Max setting Max load induced
Pressure: 270 bar (4000 psi)
Relief setting: 350 bar (5000 psi)
Cartridge material Working parts hardened & ground steel
External surface zinc plated
Body material Standard aluminium (up to 210 bar*)
Add suffix '377' for steel option
Mounting position Unrestricted
Cavity Number A12336 (See section M)
Torque cartridge into cavity 60 Nm (44 ibs ft)
Weight 1CEOMS95 2.16 kg (4.75 lbs)
(inc cartridges) 1CEEOMS95 2.26 kg (4.97 lbs)
Seal kit number 1CEOMS95 SK1282 (Nitrile) SK1282V (Viton)
1CEEOMS95 SK795 (Nitrile) SK795V (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt
Performance Data
M1
V1
M2
V2
CT1
M1
V1
M2
V2
CT2
M1
V1
M2
V2
CT1
CT2
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 K-481.A
An Eaton Brand
K
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Pressure Drop
1CEOMS95/1CEEOMS95 - Motor Mounted Valves
OMS Mounting Pattern Single and Dual Overcenter Valves
4:1 Version
Cavity plug part number
Nitrile
AXP14434-02-N
Viton
AXP14434-02-V
Model Code
1CE*OMS95-* F 4W 35 S 4 BK
1 2 3 4 5 6 7
1 Basic Code
1CEEOMS95 - Double
Cartridge and Body
1CEOMS95-1 - Single
overcenter in line V1-M1
1CEOMS95-2 - Single
overcenter in line V2-M2
2 Adjustment Means
F - Screw Adjustment
6 Pilot Ratio
4 - 4:1
8 - 8:1
7 Mounting
BK - Bolt Kit
4 Pressure Range
Note: Code based on pressure
in bar.
20 - 70-225 bar.
Std setting 100 bar
35 - 200-350 bar.
Std setting 210 bar
Std setting made at 4.8 L/min
* Cartridges must not be adjusted above
the safe working pressure of the motor
5 Seals
S - Nitrile
(For use with most industrial
hydraulic oils)
SV - Viton
(For high temperature and
most special uid applications)
Code V1 & V2 Brake Housing Number
4W 1/2" BSPP 1/4" BSPP BXP24055-4W-S
3 Port Size
35.00
(1.38)
42.00
(1.65)
90.00 (3.54)
21.00
(0.82)
32.00
(1.26)
127.00
(5.00)
62.0
(2.44)
approx
62.00 (2.44)
66.00 (2.60)
24.00
(0.94)
91.00
(3.58)
2 overcentre valves
1CE90-F**-*-*
CT2 CT1
M2
M1
V1 V2
Complete Valve 1/2" Ports
Basic Code: 1CEEOMS95
Dimensions
mm (inch)
Check motor mounting
compatibility before
specifying.
Tightening torque of “F”
adjuster locknut - 20 to 25 Nm
Note: For applications over
210 bar (3000 psi), please con-
sult our technical department
or use the steel body option.
Flow - L/min
Pressure - psi
Pressure - bar
Flow - US gpm
0 25 50 75 100
0 6.5 13 19.5 26
240
210
180
150
120
90
60
30
0
16
14
12
10
8
6
4
2
0
Free ow
Piloted open
Flow - L/min
Pressure - psi
Pressure - bar
Flow - US gpm
0 25 50 75 100
0 6.5 13 19.5 26
600
500
400
300
200
100
0
42
35
28
21
14
7
0
Free ow
Piloted open
8:1 Version