EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 D-790.A
An Eaton Brand
D
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 132 L/min (35 USgpm)
Internal leakage 164 cc/min (10 in
3
/min) maximum @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Pilot pressures 40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
160 - 11,0 bar (160 psi)
Pilot displacement volume 1,97 cm
3
(0.12 in
3
)
Cavity C-16-4
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum
Weight cartridge only 0,5 kg (1.12 lbs)
Seal kit 889634 (Buna-N), 889638 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
PTS6-16 - Pilot to Shift Valve
Pilot operated, directional control valve
132 L/min (35 USgpm) • 210 bar (3000 psi)
Description
This is a 3-way 2 position,
pilot operated directional
control valve ideal for selecting
a function when the pilot
pressure is applied or removed.
Operation
This valve allows flow
between ports 3 and 4 while
blocking port 2 until sufficient
pressure has been applied to
port 1 and the spring bias is
overcome.
Performance Data
At this time, flow is directed
between port 2 and port 3
while blocking port 4. During
the cross-over transition, all
ports are open. The spring
chamber for this valve is
vented to port 4.
Features
Hardened, ground and honed
sleeve and spool for low
internal leakage.
Pressure Drop Curves
Cartridge only
Sectional View
2
3
1
4
54
2
4
3
1
6
5
4
3
2
1
0
80
70
60
50
40
30
20
10
0
0 5 10 15 20 25 30 35
20 40 80 100 110600
4
2
3
1
Flow - L/min (21,8 cSt oil @ 49°C)
Flow - USgpm (105 SUS oil @ 120°F)
Pressure Drop - psi
Pressure Drop - bar
Port 4 to 3 or 3 to 2
2
4
3
1
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 D-791.A
An Eaton Brand
D
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
38,1 (1 .50) H e
x
2
4
3
1
25,38 (0.999)Ø
26,95 (1.061)Ø
28,55 (1.124)Ø
1.312"-12 Thd.
28,6
(1.12)
101,6
(4.00)
PTS6-16 - Pilot to Shift Valve
Pilot operated, directional control valve
132 L/min (35 USgpm) • 210 bar (3000 psi)
16 **** 00
Model Code
1
Function
PTS6 - Pilot to shift valve
2
Size
16 - 16 size
3
Seal Material
Blank - Buna-N
V - Viton
®
Code Port Size Housing Number
Aluminum Aluminum Steel
Light Duty Fatigue Rated
0 Cartridge
A12T SAE 12 566411
A6B 3/4" BSPP 02-175468
A10H SAE 10 876729
A12H SAE 12 876731
A4G 1/2" BSPP 876728
A6G 3/4" BSPP 876730
See section J for housing details.
4
Port Size
5
Pilot to shift (nominal)
40 - 2,75 bar (40 psi)
80 - 5,5 bar (80 psi)
160 - 11,0 bar (160 psi)
6
Special Features
00 - None
(Only required if valve has special
features, omitted if “00”.)
1 2
3
4 5 6
PTS6
(V)
***
Dimensions
mm (inch)
Torque cartridge in
aluminum housing
108-122 Nm (80-90 ft lbs)
Installation DrawingCartridge Only
114.3
(4.50)
139.7
(5.50)
28.6
(1.13)
93.68
(3.688)
114.3
(4.50)
31.8
(1.25)
63.5
(2.500)
85.6
(3.37)
28.4
(1.12)
4
2
1
3
2 Slots
8.74
(0.344)
10.3
(0.41)
57
(2.24)
31.8