EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009A-340.A
An Eaton Brand
A
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F)
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 310 bar (4500 psi)
Rated flow 45 L/min (12 USgpm)
Internal leakage less than 5 drops/min, max @ 350 bar (5000 psi)
Temperature range -40° to 100°C (-40° to 212°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Cavity C-10-2
Fluids All general purpose hydraulics fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/16/13
Housing material (standard) Steel
Weight including coil 0,18 kg (0.39 lbs)
Seal kit 565803 (Buna-N), 566086 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Operation
In the de-energized position
the valve allows free flow in
both directions.
When the solenoid is ener-
gized the pilot poppet closes
the orifice and the valve closes
blocking flow from port 2 to 1
while allowing free flow from
port 1 to 2.
Features
Hardened and ground work-
ing parts. Lapped seat for
low leakage. IP69K Tough coil
compatibility. Continuously
rated. Compact design with low
pressure drop. 350 bar working
pressure.
Description
This is a 2-way, 2-position, pop-
pet type, high pressure, pilot
operated, normally open sole-
noid valve. This valve is used in
applications requiring low leak-
age, such as load holding appli-
cations or as a general purpose
diverter or dump valve.
Application Note:
This value is pilot operated and
requires a minimum flow of 1-2
L/min (0.3-0.5 USgpm) in order
to shift. For operation at very
low flow conditions contact
your Eaton representative.
SV13-10-O/OP/OS - Solenoid Valve
Poppet type, normally open solenoid valve (free reverse flow)
45 L/min (12 USgpm) • 350 bar (5000 psi)
Pressure Drop
Cartridge only
Performance Sectional View
Port 1 to port 2 and port 2
to port 1 de-energized
2
1
7
5
3
1
100
75
50
25
0 8 15 23 30 38 45
Flow - L/m in (21,8 cSt oil @ 49°C)
0 2 4 6 8 10 12
Flow - USgpm (105 SU S oil @ 120°F)
1
2