EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009A-490.A
An Eaton Brand
A
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
SV4-8-3/3M - Solenoid Valve
3-way, 2-position spool type solenoid valve
13 L/min (4 USgpm) • 210 bar (3000 psi)
Description
This is a 3-way 2-position,
direct acting, spool type sole-
noid valve. This valve can be
used in applications requiring
separate pressure and tank
lines, such as a single acting
cylinder or any other applica-
tion where a three way two
position solenoid valve is
needed.
Operation
In the de-energized position
this valve allows flow from
port 2 to 1 while port 3 is
blocked.
In the energized position flow
is allowed from port 2 to port
3 while port 1 is blocked.
Features
Hardened, ground and honed
working parts to limit leakage.
IP69K Tough coil compatibility.
Continuously rated. Compact
design with low pressure drop.
Rated pressure on all ports.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 13 L/min (4 USgpm)
Internal leakage 82 cm3/min (5 in3/min) max @ 210 bar ( 3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Response times (100% rated voltage and flow) Energize: 22 ms
De-Energize: 27 ms
Cavity C-8-3
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/16/13
Housing material (standard) Aluminum
Weight including coil 0,29 kg (0.64 lbs)
Seal kit 02-160755 (Buna-N), 02-160756 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
Performance Data
Sectional View
Pressure
Drop
3
2
25
50
75
100
125
150
2
4
10
8
6
0 4 8 12
Flow - L/m in (21,8 cSt oil @ 49°C)
0 1 2 3 4
Flow - U Sgpm (105 SUS oil @ 120°F)
500
1000
1500
2000
2500
3000
35
200
170
140
100
70
230
161240 188
Flow - L/m in (21,8 cSt oil @ 49°C)
A
B
C
0 1 2 3 4 5
Flow - U Sgpm (105 SUS oil @ 120°F)
Operating Limits
A - Normally open port 1 to port 2
B - Normally closed port 3 to port 1
C - Selector 2 to 1 and 2 to 3
Pressure Drop vs. Flow
Port 2 to 1 and
port 2 to port 3
Note: Pressure on port 1 should not exceed 20 bar (300 psi).
3
1
2