EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009A-190.A
An Eaton Brand
A
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Cartridge fatigue pressure (infinite life) 210 bar (3000 psi)
Rated flow 114 L/min (30 USgpm)
Internal leakage (port 2 to port 1) less than 5 drops/min, max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Coil duty Continuous from 85% to 110% of nominal voltage
Response times (100% rated voltage and flow) Energize: 75 ms
De-Energize: 150 ms
Cavity C-12-2 or C-12-2U
Add “U” after number if undercut is required. If undercut is not specified,
expect 10 psi @ 15 USgpm and 20 psi @ 30 USgpm higher pressure drop.
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20 etc.
Filtration Cleanliness code 18/16/13
Housing material (standard) Aluminum
Weight including coil 0,336 kg (0.74 lbs)
Seal kit 02-165889 (Buna-N), 02-165888 (Viton
®
)
Viton is a registered trademark of E.I. DuPont
SV3-12-C/CM/CR - Solenoid Valve
2-way, 2-position, normally closed, poppet type solenoid valve
114 L/min (30 USgpm) • 210 bar (3000 psi)
Description
This is a 2-way, 2-position,
poppet type, pilot operated,
normally closed solenoid valve.
This valve is used in applica-
tions requiring low leakage,
such as load holding applica-
tions or as a general purpose
diverter or dump valve.
Operation
In the de-energized position
the valve blocks flow from port
2 to 1 and free flow is allowed
from port 1 to 2.
When the solenoid is ener-
gized the pilot poppet is pulled
off the seat allowing the valve
to open in both directions.
Features
Hardened and ground work-
ing parts. Lapped seat for low
leakage. IP69K Tough coil com-
patibility. Continuously rated.
Compact design with low
pressure drop.
Performance Data
Sectional View
Pressure Drop Curves
Cartridge only
A - Port 1 to port 2 de-energized
B - Port 2 to port 1 energized
2
1
100
0
50
150
200
14
10
6
1
A
B
20 40 60 80 100 1140
Flow - L/m in (21,8 cSt oil @ 49°C)
302520151050
Flow - U Sgpm (105 SUS oil @ 120°F)
2