EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009G-330.A
An Eaton Brand
G
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 240 bar (3500 psi)
Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
Rated inlet flow 19 L/min (5 USgpm)
Pilot ratio 3:1
Maximum internal leakage
Ports 2 to 3 and 3 to 2: 140 cc/min. (8.5 in³/min.) @ 240 bar (3500 psi)
Ports 4 to 3 and 1 to 2: 5 drops/min. @ 240 bar (3500 psi)
Free flow cracking pressure @ 1 L/min (0.25 USgpm) 1,72 bar (25 psi)
Temperature range –40° to 120° C (–40° to 248° F)
Cavity C-8-4
Fluids All general purpose hydraulic fluids such as
MIL - H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing material Aluminum or steel
Weight, cartridge only 0,08 kg (0.18 lbs.)
Seal kit 02-370387 Urethane
Operation
The valve allows flow from
port 2 to port 1 or from port
3 to port 4 when the spring
bias is overcome. Flow is
blocked from ports 4 to 3 and
from 1 to 2 until pilot pressure
is applied to ports 2 and 3
respectively.
Features
Hardened and ground poppets
to give minimal internal leak-
age and long life.
Pressure Drop
Performance Data
Sectional View
DPC2-8 - Check Valve
Dual, pilot-to-open, poppet type
19 L/min (5 USgpm) • 240 bar (3500 psi)
Description
This is a dual pilot-to-open
check valve ideal for stabilizer
cylinders fitting directly into
the cylinder reducing pipework
to a minimum.
A – Port 2 to Port 1
B – Port 3 to Port 4
WARNING
Do not use
Pilot-to-Open Check
Valves in load holding
applications where either
overrunning loads are
possible or load release
speed is critical. Failure to
observe these guidelines may
result in bodily injury or
damage to equipment.
300
200
100
0
0 1 2 3 4 5
A
B
20
15
10
5
0
0 5 10 15 20
Flow - L/min (21,8 cSt oil @ 49˚C)
Flow in USgpm (1 05 SUS oil @ 1 20˚F)
Pressure - bar
Pressure - psi
4
1
2 3
2
1
3
4
EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 G-331.A
An Eaton Brand
G
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
1 Function
DPC2 - Dual pilot operated
check
2 Size
8 - 8 size
3 Seal Material
U - Urethane
4 Pilot Leakage
A - Standard
Model Code
DPC2-8 - Check Valve
Dual, pilot-to-open, poppet type
19 L/min (5 USgpm) • 240 bar (3500 psi)
7 Port Size
1 2 3 4 5 6 7 8
Code Port Size Housing Number
Aluminum Steel
Fatigue Rated Fatigue Rated
0 Cartridge only
2G 1/4" BSPP 02-160747 02-160753
3G 3/8" BSPP 02-160748 02-160754
4T SAE 4 02-160749 02-160751
6T SAE 6 02-160750 02-160752
See section J for housing.
8 Special Features
00 - None
(Only required if valve has
special features, omitted
if "00")
5 Crack Pressure
25 - 1,7 bar (25 psi)
6 Body
Omit for cartridge only
A - Aluminum
S - Steel
WARNING
Aluminum housings
can be used for
pressures up to 210 bar (3000
psi). Steel housings must be
used for operating pressures
above 210 bar (3000 psi).
00
22.2 (0.875) H ex
3/4-16 UNF -2A
8.6 (0.34)
55.9 (2.20)
12.6 (0.49)
14.2 (0.560)
15.8 (0.622)
4
3
2
1
DPC2 8 U
A 25 * **
Dimensions
mm (inch)
Note: Torque cartridge in
Aluminum or Steel housing to
34-41 Nm (25-30 ft. lbs).
Installation Drawing (Steel)Cartridge Only
Basic Code
4SK140
82.6
(3.25)
73
(2.88)
3.20
(0.13)
57.15
(2.250)
2-Slots
7.14
(0.281)
44.0
(1.73)
15.5
(0.61)
8.6
(0.34)
19.1
(0.75)
1
4
2
3
38.1
(1.500)
19.1
(0.75)
29.8