5
Maximum Recommended Flow Rate
Valve model code
Flow rate
L/min (USgpm)
R**-03
R**-06
R**-10
45 (12)
113 (30)
284 (75)
Hydraulic Fluids
Materials and seals used in these
valves are compatible with:
Anti-wear petroleum oils L-HM. . . . . . . .
Non-alkyl based
phosphate esters L-HFD. . . . . . . . . . . . .
The extreme operating range is 13 to
500 cSt (70 to 2300 SUS) but the
recommended running range is 13 to
54 cSt (70 to 250 SUS). For further
technical information about fluids see
Technical Information leaflet B-920 or
I-286-S.
Contamination Control Requirements
Recommendations on contamination
control methods and the selection of
products to control fluid condition are
included in Vickers publication 9132 or
561, “Vickers Guide to Systemic
Contamination Control”. The book alos
includes information on the Vickers
concept of “ProActive Maintenance”.
The following recommendations are
based on ISO cleanliness levels at
2 mm, 5 mm and 15 mm. For products in
this catalog the recommended levels
are:
0 to 210 bar (3000 psi) 18/16/13. . . . . .
Temperatures
For petroleum oil:
Min. –20_ C (–4_F). . . . . . . . . . . . . . . . . .
Max.* +70_C (158_F). . . . . . . . . . . . . . . .
* To obtain optimum service life from both
fluid and hydraulic system, 65_C (150_F)
normally is the maximum temperature.
For other fluids where limits are outside
those of petroleum oil, consult fluid
manufacturer or Vickers representative.
Whatever the actual temperaure range,
ensure that viscosities stay within those
specified under “Hydraulic Fluids”.
Ambient for:
All valves at full performance
specification: 0 to +70_C (32 to
+158_F).
Storage:
–25 to +85_C (–13 to +185_F)
Pressure Adjustment
Adjust pressure by loosening locknut
and turning adjusting screw in
appropriate direction, clockwise to
increase pressure counter-clockwise to
decrease pressure.
Pressure settings must be at least
17 bar (250 psi) lower than the system
relief setting.
The remote pressure control connection
on valve types 3 and 4 must be
connected to an external pilot pressure
source sufficient to operate the valve at
the desired pressure and flow
conditions.
All models, except those with X, Y or Z
pressure range and all R(C)G(O)-03, are
available with an auxiliary remote control
connection. Required pressure at the
auxiliary connection is 6.25% of the
normally required control pressure for
the F pressure range and 12.5% of the
normally required control for the A, B
and D pressure range.