CG2V-6*W-10 relief valve
February 1996 GB-2323A
CG2V-6/8, 10 Series; CG5V-6/8, 20 Series
Typical Section
Basic Characteristics
Maximum pressure 350 bar. . . . . . . . . .
(5000 psi)
Maximum flow 400 L/min. . . . . . . . . . . . .
(106 USgpm)
Mounting face to ISO 6264:
CG*V-6 valves AR-06-2-A. . . . . . . . . . . .
CG*V-8 valves AS-08-2-A. . . . . . . . . . .
General Description
These two-stage valves are used to limit
or control pressure by directing up to the
total system fluid flow to reservoir when
system pressure reaches the setting of
the valve. System actuators are thus
protected against overload.
Each relief valve incorporates a vent
port that can be connected to a separate
pilot control valve to remotely control or
unload system pressure.
Two types of valve are presented in this
catalog:
F CG2V-***, 10 series: relief/sequence
valve with integral manual adjustment
of pressure setting.
F CG5V-***, 20 series: relief valve with
solenoid operated pilot valve for
loading/unloading.
A third type, KCG-*, 10 series, with
proportional pilot control valve, is
described in catalog 2324.
Features and Benefits
F Close matching to application
requirements from choice of four
adjustment control ranges covering
3 to 350 bar (44 to 5000 psi).
F Electrical on/off load from solenoid
controlled models.
F Remote parallel control by other pilot
valves connected to “vent” port.
F High machine productivity resulting
from full system flow being available
for work output until system pressure
is very close to valve setting.
F Pressure override optimized without
detriment to other performance
parameters.
F Excellent repeatability and stable
performance from cartridge-type
design of mainstage parts.
F Low off-load power wastage.
F International mounting interfaces.
F Low installed cost and space
requirement from high power/size
ratios (more than double that of many
conventional designs).
Pressure Relief and Sequence Valves
Vickers
®
Pressure Relief
XP T
XP T
Side
drain
port
Y If a valve with an integral, reverse free-flow
check is required, use a type RCG valve,
as in catalog 429.
PT
XP T
AB
For Valves with Manual Adjustment Only
(F3-)
Fluid compatibility
Blank = Antiwear hydraulic oil
(class L-HM), invert emulsion
(class L-HFB) or water glycol
(class L-HFC)
F3 = As above or phosphate
ester (class L-HFD)
Mounting surface, ISO 6264
6 = AR-06-2-A
8 = AS-08-2-A
Pressure adjustment
control range
B = 3 to 70 bar (44 to 1000 psi)
C = 3 to 140 bar (44 to 2000 psi)
F = 3 to 210 bar (44 to 3000 psi)
G = 3 to 350 bar (44 to 5000 psi)
Type of manual adjustment
K = Micrometer with keylock
M = Micrometer without keylock
W = Screw/locknut
Drain options
1 = External drain from side port:
CG2V sequence-version
(see Functional Symbols)
Omit for CG2V relief-version and
for CG5V models
Manual override options,
CG5V only
Override in solenoid end
Blank = Plain override
H = Water-resistant override,
DC solenoid only
Z = No override
CG2V-* * * -1*
1 2 3 4 11
1
2
3
4
(-1)
5
For Valves with Manual Adjustment Plus Electrical Load/Unload
(F3-)CG5V-* * *
1 2 3 4 9
-D(-*)-(V)M- *** (-L)- * 5-2*
6 7 8 10 11
Solenoid energization identity,
CG5V only
V = Solenoid A at port A end of
pilot valve (energizing A
connects P to B pilot ports):
German practice.
Omit for solenoid identity B
(energizing B connects P to B
pilot ports): USA ANSI B93.9/
NFPA standard.
Solenoid connection typeY,
CG5V only
U = ISO 4400 (DIN 43650)z
FW =
1
/
2
I NPT thread conduit box
FTW=
1
/
2
I NPT thread conduit box and
terminal strip
FJ = M20 thread conduit box
FTJ = M20 thread conduit box and
terminal strip
Y Other connection types as shown in
catalog 2015 (DG4V-3/3S) may be made
available depending on quantities.
z Female connector to be supplied by user.
Indicator lights, CG5V only
Option for solenoid connection types
FTW and FTJ, see position
L = Lights fitted
Omit if lights not required
For U-code solenoid, use plug with
integral light, see Electrical Plugs and
Connectors
5
6
8
9
7
8
2
Functional Symbols
Relief valve, manually adjusted,
CG2V-***-1* model
Sequence valve, manually adjusted,
CG2V-***-1-1* modelY
Solenoid controlled relief valve, pilots
internally drained, CG5V-***-D-2* model
Model Codes
11
10
Coil rating, CG5V only
See Operating Data for further
information
A = 110V AC 50 Hz
BJ = 110V AC 50 Hz/120V AC 60 Hz
C = 220V AC 50 Hz
DJ= 220V AC 50 Hz/240V AC 60 Hz
G = 12V DC
H = 24V DC
J For 60 Hz or dual frequency.
Design number
10 series for CG2V valves
20 series for CG5V valves
Subject to change. Installation
dimensions unaltered for design
numbers 10-19 and 20-29 inclusive.
3
Operating Data
Data is typical with oil at 22 cSt (106 SUS) and at 50_C (122_F)
Maximum pressures:
Ports P and X
Port TY:
CG2V valves, 10 series
CG5V valves, 20 series
YFor relief valves this is normally connected
directly to reservoir because back pressure
here adds to the effective setting of the
valve.
350 bar (5000 psi)
350 bar (5000 psi)
100 bar (1500 psi)
CG5V, 20 series valves are designed to satisfy
the needs of most applications. Consult your
Vickers representative about an alternative
model if:
a) Valves are required to remain pressurized
for long periods without frequent switching,
and/or
b) Back pressure on port T is required to rise
above 100 bar (1500 psi).
Pressure adjustment ranges See model code
3
Maximum flow rates:
CG*V-6
CG*V-8
200 L/min (53 USgpm)
400 L/min (106 USgpm)
Vent B flow, port X, when used
BSee “Vent Function” explanation two
pages on.
3 L/min (0.8 USgpm) with valve at max.
flow rate
Drain flow, CG*V valves, when manual
adjuster and/or pilot valve (i.e. CG5V)
are in operation:
CG*V-6
CG*V-8
1,1 L/min (0.3 USgpm)
1,8 L/min (0.47 USgpm)
Response time, CG5V valves
Typical time from applying signal at
solenoid, with valve vented, until relief
main valve closes; with minimum
pressurized volume
170 ms
Hydraulic fluids and fluid temperatures See three pages on
Temperature limits See three pages on
Thermal stability
(pressure/temperature change)
0,2 bar/_C (1.6 psi/_F)
Spare parts/service information:
CG*V valves
Publication no. 40751
0
50
100
150
200
250
300
350
bar
0
1000
2000
3000
4000
5000
psi
Flow rate
0
0
100 200 400
20 40 60 80
L/min
USgpm
300
100
Pressure
4
Electrical Data, CG5V Valves
Coil voltages
See model code
10
Permissible voltage fluctuation:
Maximum
Minimum
See Temperature Limits, two pages
on
90% rated (see model code )
10
Relative duty factor Continuous; ED = 100%
Types of protection:
ISO 4400 coils with plug fitted correctly
Conduit box
Coil winding
Lead wires (coils type F**)
Coil encapsulation
IEC144 class IP65
IEC144 class IP65
Class H
Class H
Class F
Power consumption for coils listed in
model code :
AC coils:
Single frequency coils at 50 Hz
Dual frequency coils at 50 Hz
Dual frequency coils at 60 Hz
DC coils, at rated voltage and
20_C (68_F):
Type G, 12V DC
Type H, 24V DC
10
Initial z Holding
VA (RMS) VA (RMS)
225 39
265 49
260 48
30W
30W
z 1st half cycle; solenoid armature fully
retracted
Performance Data
Typical with oil at 22 cSt (106 SUS) and
at 50_C (122_F)
Pressure Override When Relieving
CG2V-8 examples
0
2
4
bar
6
0
25
50
75
psi
100 200 300
0 20 40 60 80 USgpm
Flow rate
5
3
1
400
100
Pressure
L/min
XP T
Vent valve
Venting
System pressure can be dropped to
near-zero by connecting vent port X
to reservoir through a suitable pilot
valve, e.g:
5
Pressure Override When Venting
Control Data for CG2V Valves
Manual adjustment of pressure setting
described in Installation Dimensions.
Hydraulic Remote Control
Remote adjustment of pressure setting
can be made by a pilot relief valve,
substituted for the vent valve in the
diagram. Suitable pilot relief valves are
described in catalogs 411 (type C-175
valves) and 409 (type CGR-02 valves).
Control Data for CG5V Valves
Vent Function
The solenoid operated pilot valve is
Vickers model type DG4V-3S, with spool
type 0B (ref. catalog 2015). When the
solenoid is de-energized, the CG5V
relief valve is unloaded by venting the
pilot drain to port T. Note that any back
pressure at port T is additive to the
minimum possible unloaded pressure,
and is also additive to the on-load
pressure setting.
When the solenoid is energized the pilot
flow is blocked to bring the relief valve
on load. For this function port X would
normally be blocked (e.g. no connection
from the mounting face). Further remote
control pressure settings are possible by
connecting port X to suitable pilot relief
valves via other DG4V-3S type
directional control valves.
1
10
6
Hydraulic Fluids
All valves can be used with:
Antiwear hydraulic oils (class L-HM)
Invert emulsions (class L-HFB)
Water glycol (class L-HFC)
Phosphate ester (class L-HFD), adding
F3- prefix at model code .
The extreme viscosity range is from
500 to 13 cSt (2270 to 70 SUS) but the
recommended range is 54 to 13 cSt
(245 to 70 SUS).
For further information about fluids see
Technical Information leaflet 920.
Temperature Limits
Minimum ambient: 20_C (4_F)
Maximum ambient:
For CG2V valves: 70_C (158_F)
For CG5V valves with coils listed in
model code and at 110% of rated
voltage:
Coil type and
frequency
Max. ambient
temperature
Dual frequency coils
at 50 Hz
at 60 Hz
65_C (149_F)
65_C (149_F)
Single frequency (50 Hz) coils
at 50 Hz 65_C (149_F)
DC coils 70_C (158_F)
Fluid temperatures (all models)
Petroleum
oil
Water-
containing
Min. 20_C
(4_F)
+10_ C
(+50_F)
Max.* +70_ C
(+158_F)
+54_ C
(+129_F)
* To obtain optimum service life from both
fluid and hydraulic system, 65_C (150_F)
normally is the maximum temperature
except for water-containing fluids.
For synthetic fluids consult fluid
manufacturer or Vickers
representative where limits are outside
those of petroleum oil.
Whatever the actual temperature
range, ensure that viscosities stay
within the limits specified in the
Hydraulic Fluids section.
Contamination Control
Requirements
Recommendations on contamination
control methods and the selection of
products to control fluid condition are
included in Vickers publication 9132 or
561, Vickers Guide to Systemic
Contamination Control. The book also
includes information on the Vickers
concept of ProActive Maintenance.
The following recommendations are
based on ISO cleanliness levels at
2 mm, 5 mm and 15 mm. For products in
this catalog the recommended levels
are:
Up to 210 bar (3050 psi) 19/17/14. . . . .
Above 210 bar (3050 psi) 19/17/14. . . .
Installation Dimensions in mm (inches)
3rd angle
projection
BC
D
62_
A
EE
GH
F
J
For CG2V-***-1-1* models (sequence valve application):
G
1
/
4
(
1
/
4
I BSPF) drain port, supplied plugged
K
45,0 (1.8) for removal
of protective cap
7,5 (0.29) A/F
Turn clockwise to increase
pressure setting
17,0 (0.67) A/F
77,5 (3.1)
L
16,0 (0.63)
100,0 (4.0)
CG2V-***-1*
models
122,0 (4.8)
CG2V-***-1-1*
models
Alternative vent port G
1
/
4
(
1
/
4
I BSPF).
Remove plug for access.
Port X
(vent port)
Port P Port T
With adjuster knob fully out:
196,0 (7.7) for CG*V-6 models
203,0 (8.0) for CG*V-8 models
25,0
(1.0)
18,0 (0.7) for key removal
Type K only:
Micrometer Adjustment Options:
“K” or “M” in Model Code
“K” Feature
To adjust pressure setting, insert key
and turn clockwise. Turn micrometer
knob clockwise to increase pressure
setting; counter-clockwise to decrease
setting. When the key is removed the
knob can spin freely without affecting the
pressure setting.
4
7
CG2V Models
Model A B C D E rad. Ø F (dia) G
CG*V-6 58,0
(2.3)
35,0
(1.4)
68,0
(2.7)
35,0
(1.4)
12,0
(0.5)
20,0
(0.78)
79,0
(3.1)
CG*V-8 42,0
(1.7)
39,0
(1.54)
83,0
(3.3)
30,0
(1.2)
16,0
(0.63)
26,0
(1.02)
103,0
(4.1)
Model H Ø J (dia) K L M
(AC coils)
M
(DC coils)
CG*V-6 82,0
(3.23)
13,5
(0.53)
176,0
(7.0)
20,0
(0.78)
160,0
(6.3)
170,0
(6.7)
CG*V-8 106,0
(4.2)
17,0
(0.7)
183,0
(7.2)
25,0
(1.0)
169,0
(6.65)
179,0
(7.1)
8
With Type U Coil Connection
(U at model code )
For dimensions B and M, see previous page.
z May vary dependent on plug source.
Y Plug not supplied; order separately if required.
For available plug types see section Electrical Plugs and
Connectors.
With Type F Coil Connection
(F(T)J or F(T)W at model code )
8
J Ref. model code :
Codes FJ and FW: 2 lead wires for each solenoid,
approx.150,0 (6.0) long. M3 terminals provided for
customer connection.
Codes FTJ and FTW: lead wires connected into terminal
strip suitable for M3 terminals on customer connection.
For dimensions B and M, see previous page.
186,0 (7.4) J
M
For manual override type H:
15,0 (0.6)
AC solenoid: 45,0 (1.8)
DC solenoid: 61,0 (2.4)
For coil removal:
B
Solenoid identity (printed on
nameplate of pilot valve) is:
Sol. A to German practice
Sol B to ANSI/NFPA standard
(For solenoid identity methods
see Model Code )
Y
13,0 (0.5) for
plug removal
7
M
For manual override type H:
15,0 (0.6)
AC solenoid: 45,0 (1.8)
DC solenoid: 61,0 (2.4)
For coil removal:
Solenoid identity (printed on
nameplate of pilot valve) is:
Sol. A to German practice
Sol B to ANSI/NFPA standard
(For solenoid identity methods
see Model Code )
190,0 (7.5)
Y
B
Ground (earth) connection:
Ø4,0 (0.16 dia) self-tapping
screw
7
8
8
CG5V Models
Valve locating pin
Port T
(outlet to reservoir)
Port P (pressure inlet)
Valve locating pin
Port X, vent or
remote control port
Port X, vent or
remote control port
Port T
(outlet to reservoir)
Port P (pressure inlet)
CGVM-6-10-R Subplate
55,0
(2.2)
21,0
(0.83)
20,0
(0.79)
2 ports, G1 (1I BSPF) x 19,0 (0.75)
min. depth full thread, from underside
Ø 7,5 (0.29 dia) x 6,0 (0.24)
deep, for valve locating pin
4 holes, Ø 11,0 (0.43 dia)
through, Ø 17,5 (0.68 dia)
spotface
G
1
/
4
(
1
/
4
I BSPF) x 12,0 (0.47) min.
depth full thread, from underside
4 holes tapped M12 x 21,0
(0.82) min. depth full thread
24,0
(0.95)
132,0 (5.2)
80,0
(3.15)
125,0 (5.0)
101,0
(4.0)
68,5
(2.7)
26,9
(1.06)
7,0
(0.27)
56,0 (2.2)
150,0 (6.0)
P
T
X
21,7
(0.85)
9
Views on Bottom Faces of Valves
See also Mounting Surfaces.
All O-seals supplied.
CG*V-6 CG*V-8
M (min.)
A (min.)
B (min.)
D (min.)
K (min.)
Cs
Ls
E
H
J
N
Q (min.)
Ø 7,5 (0.29 dia) x 6,0
(0.24) deep min.
P
T
X
Fs
Y
Plug or omit if this vent/hydraulic
remote port is not to be used
10
Mounting Surfaces, ISO 6264
AR-06-2-A
AS-08-2-A
When a subplate is not used a raised
pad must be provided for mounting. The
pad must be flat within
0,001 mm/100 mm (0.0001I/10I) and
smooth within 0,8 mm (32 min).
Dimensional tolerances are
"0,2 mm (0.008I) except where
indicated.
Port functions
P = Pressure inlet
T = Outlet to reservoir
X = Vent, or remote pilot control port
Size A B C D E F H J K L
AR-06 80 (3.2) 13,1 (0.5) 53,8 (2.12) 13,1 (0.5) 47,5z (1.87) 22,1 (0.87) 22,1z (0.87) 0 (0) 13,1 (0.5) 53,8 (2.12)
AS-08 118 (4.7) 35,0 (1.4) 66,7 (2.63) 16,3 (0.7) 55,6 (2.19) 33,4 (1.35) 11,1 (0.44) 23,8 (0.94) 16,0 (0.63) 70,0 (2.76)
Size M N Ø P (dia) Q Ø T (dia) Ø X (dia) Y thread x min. full thread depth
AR-06 13,1 (0.5) 26,9 (1.06) 14,7 (0.58) 80 (3.2) 14,7 (0.58) 4,8 (0.19) M12 x 21 (
7
/
16
I UNF x 0.83) B
AS-08 16,0 (0.63) 35,0 (1.38) 23,4 (0.92) 102 (4.0) 23,4 (0.92) 6,3 (0.25) M16 x 30 (
5
/
8
I UNF x 1.2) B
Y Tolerance on bolt and pin locations "0,1 (0.004).
z These ISO standard dimensions can be used, but improved flow paths to and from valve are
obtained by using 48,0 (1.89) instead of 47,5 (1.87), and 22,6 (0.89) instead of 22,1 (0.87).
B ISO standard does not give UNC bolt sizes. These are recommended equivalents to metric
sizes specified in the standard.
Installation Data
Mounting Attitude
Unrestricted.
Subplates
For CG*V-6 valves see type
CGVM-6-10-R on previous page.
For CG*V-8 valves consult your Vickers
representative.
Mounting Bolts/Torques
For CG*V-6 valves: bolt kit BKCG2V-6.
Bolts should be torqued to 103-127 Nm
(76-94 lbf ft), with threads lubricated.
For CG*V-8 valves: bolt kit BKCG2V-8.
Bolts should be torqued to 257-315 Nm
(190-232 lbf ft), with threads lubricated.
Mass (approx.)
CG2V-6 3,5 kg (7.7 lb). . . . . . . . . . . . . . .
CG2V-8 4,4 kg (9.7 lb). . . . . . . . . . . . . . .
CG5V-6:
With AC solenoid 5,0 kg (11 lb). . . . . . . .
With DC solenoid 5,2 kg (11.5 lb). . . . . .
CG5V-8:
AC solenoid 5,9 kg (13 lb). . . . . . . . . . . .
DC solenoid 6,1 kg (13.5 lb). . . . . . . . . .
Electrical Plugs and Connectors
8
For CG5V valves with type F(T)J or F(T)W coils, see model code 8
For FTJ or FTW at model code
F 1.For DC coils the +ve lead(s) must be
connected to the terminal(s) marked +.
When using 3-wire incoming leads to
double solenoid valves (i.e. common
neutral) the inner pair of terminals must
be linked.
2. For correct light indication of energized
solenoid ensure that solenoid leads are
correctly connected: light terminals are
common with each outer pair of solenoid
terminals according to the side with +
mark.
8 For FTJL or FTWL at model code +
8 9
Terminal strip (part number 890345)
clips to cover and can be field-fitted
M3 x 0,5-6H screws (part
number 186006) 2 each end
Connections to solenoid A
(or B, according to model type) F
Connections to solenoid B
(or A, according to model type) F
Rubber gasket
Conduit box cover and nameplate
complete with sealing gasket and
4 screws
Anti-rotation tab ensures
correct orientation of cover
to junction box
28,50
(1.12)
30,00
(1.18)
Lights
2 lenses in cover
4 terminal screws M3 x 0,5-6H
(part number 02-113355)
11
Plugs for ISO 4400 (DIN 43650) Type
Coil Connection
For CG5V valves with type U coils
(model code )
The cable entry on these plugs can be
repositioned at 90_ intervals by
reassembly of the contact holder relative
to the plug housing. The cable entry is
Pg11 for cable Ø 6-10 mm (0.24-0.4I).
Terminal Strip and Lights
Ordering Procedure
Valves, subplates and bolt kits should be
ordered by full model code designation.
Order plugs by part number.
Order plugs separately by part number.
Voltage
Part number
Gray
(Sol.A)
Black
(Sol.B)
Without indicator light
710776 710775
With indicator light
12- 24V
100-125V
200-240V
977467
977469
977471
977466
977468
977470